Thermodynamic analysis of ammonia-water power/chilling cogeneration cycle with low-grade waste heat

被引:48
作者
Hua, Junye [1 ,2 ]
Chen, Yaping [1 ]
Wang, Yaodong [2 ]
Roskilly, A. P. [2 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[2] Newcastle Univ, Sir Joseph Swan Ctr Energy Res, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
基金
英国工程与自然科学研究理事会;
关键词
Ammonia-water; Cogeneration cycle; Circulation multiple; Solution concentration; Thermal performance; POWER-GENERATION;
D O I
10.1016/j.applthermaleng.2013.12.043
中图分类号
O414.1 [热力学];
学科分类号
摘要
An ammonia-water absorption cycle for power and chilling output cogeneration from mid/low-grade waste heat was analyzed and optimized, which is a modified Kalina cycle adding an evaporator and a subcooler to realize the chilling effect. The cycle achieves higher efficiency by generating chilling output from proper internal recuperation process without consumption of additional heat resource and by realizing heat transfer with suitable ammonia concentrations for variable phase change processes to match both heat source and cooling water. Analysis of the impact of key parameters for the system on the thermal and exergy efficiencies was carried out. The results show that there are matching basic and work concentration pairs for a higher efficiency. The smaller circulation multiple and greater chilling fraction are favorable to the efficiencies but restricted respectively by heat transfer constraint of recuperator and the demand. The calculation example with the turbine inlet parameters set at 195 degrees C/2.736 MPa and the cooling water inlet temperature set at 25 degrees C with chilling fraction of 0.5 shows that the thermal efficiency and exergy efficiency reach up to 16.4% and 48.3%, about 24.24% and 8.16% higher than those of an ammonia-water power cycle under identical condition. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:483 / 490
页数:8
相关论文
共 23 条
  • [1] Exergoeconomic evaluation of electricity generation by the medium temperature geothermal resources, using a Kalina cycle: Simav case study
    Arslan, Oguz
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (09) : 1866 - 1873
  • [2] Chen Y. P., 1997, THERM POWER GENERAT, V47, P20
  • [3] Chen Y.P., 2009, P 6 INT S HEAT VENT
  • [4] Chen YP, 1989, J SE U, V19, P52
  • [5] Optimal design of binary cycle power plants for water-dominated, medium-temperature geothermal fields
    Franco, Alessandro
    Villani, Marco
    [J]. GEOTHERMICS, 2009, 38 (04) : 379 - 391
  • [6] Performance evaluation of Kalina cycle subsystem on geothermal power generation in the oilfield
    Fu, Wencheng
    Zhu, Jialing
    Zhang, Wei
    Lu, Zhiyong
    [J]. APPLIED THERMAL ENGINEERING, 2013, 54 (02) : 497 - 506
  • [7] Analysis of a new thermodynamic cycle for combined power and cooling using low and mid temperature solar collectors
    Goswami, DY
    Xu, F
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (02): : 91 - 97
  • [8] Thermodynamic analysis of simplified dual-pressure ammonia-water absorption power cycle
    Hua Jun-ye
    Chen Ya-ping
    Liu Hua-jin
    Wu Jia-feng
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (03) : 797 - 802
  • [9] Ingley HA, 2005, P SOL WORLD C ORL FL
  • [10] KALINA AI, 1984, J ENG GAS TURB POWER, V106, P737, DOI 10.1115/1.3239632