A universal SPICE model for signal analysis of a straw tube detector

被引:2
作者
Lan, Kejian A. [1 ]
Cui, Yonggong [1 ]
Hungerford, Ed V. [1 ]
机构
[1] Univ Houston, Dept Phys, Houston, TX 77204 USA
关键词
crosstalk; noise; position resolution; resistive cathode; simulation; straw tube;
D O I
10.1109/TNS.2006.874075
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A universal SPICE model of the MECO straw detector and its readout system was developed. This model is able to reproduce the signals from the anode wires and the induced charge distribution on the cathode strips. Results from model calculations were compared to test results of a short prototype. Based on the successful reproduction of the experimental results, we used the model to help select parameters to optimize the design of the full scale MECO tracker. This model provides complete signal analysis of the current flows for both anode and cathode readout. In addition, a dual straw model was constructed to calculate the crosstalk and noise between adjacent straws. This paper describes the simulation and test results.
引用
收藏
页码:1390 / 1396
页数:7
相关论文
共 19 条
[1]  
BLOOM W, 1993, PARTICLE DETECTION D
[2]   CATHODE CHARGE-DISTRIBUTIONS IN MULTIWIRE CHAMBERS .1. MEASUREMENT AND THEORY [J].
GORDON, JS ;
MATHIESON, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (02) :267-276
[3]  
Kleinknecht K., 1998, DETECTORS PARTICLE R
[4]   A pipelined front-end, timing and amplitude digitizing system [J].
Lan, KA ;
Cui, Y ;
Hungerford, EV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2362-2367
[5]   Development of a straw tube chamber with pickup-pad readout [J].
Leonidopoulos, C ;
Lu, C ;
Schwartz, AJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 427 (03) :465-486
[6]   Signal propagation in straw tubes with resistive cathode [J].
Marzec, J ;
Zaremba, K ;
Pawlowski, Z ;
Konarzewski, B .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (01) :18-24
[7]   Transparency of the straw tube cathode for the electromagnetic field [J].
Marzec, J ;
Zaremba, K ;
Pawlowski, Z ;
Konarzewski, B .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (02) :548-552
[8]   CATHODE CHARGE-DISTRIBUTIONS IN MULTIWIRE CHAMBERS .2. APPROXIMATE AND EMPIRICAL FORMULAS [J].
MATHIESON, E ;
GORDON, JS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (02) :277-282
[10]   REDUCTION IN NON-LINEARITY IN POSITION-SENSITIVE MWPCS [J].
MATHIESON, E ;
SMITH, GC .