Detailed characterization of the kinetic performance of first and second generation silica monolithic columns for reversed-phase chromatography separations

被引:38
|
作者
Cabooter, Deirdre [1 ]
Broeckhoven, Ken [2 ]
Sterken, Roman [1 ]
Vanmessen, Alison [1 ]
Vandendael, Isabelle [3 ]
Nakanishi, Kazuki [4 ]
Deridder, Sander [2 ]
Desmet, Gert [2 ]
机构
[1] Katholieke Univ Leuven, Dept Pharmaceut Sci, B-3000 Louvain, Belgium
[2] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[3] Vrije Univ Brussel, Fac Engn Mat & Chem, B-1050 Brussels, Belgium
[4] Kyoto Univ, Dept Chem, Sakyo Ku, Kyoto 6058502, Japan
关键词
Second generation silica monoliths; Kinetic performance; Characteristic length; Flow resistance; TOTAL PORE BLOCKING; SOL-GEL SYSTEM; LIQUID-CHROMATOGRAPHY; DIFFUSION-COEFFICIENTS; EDDY DISPERSION; HIGH-PRESSURE; HPLC; EFFICIENCY; TERM; GENERATION;
D O I
10.1016/j.chroma.2013.11.047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The kinetic performance of commercially available first generation and prototype second generation silica monoliths has been investigated for 2.0 mm and 3.0-3.2 mm inner diameter columns. It is demonstrated that the altered sol-gel process employed for the production of second generation monoliths results in structures with a smaller characteristic size leading to an improved peak shape and higher efficiencies. The permeability of the columns however, decreases significantly due to the smaller throughpore and skeleton sizes. Scanning electron microscopy pictures suggest the first generation monoliths have cylindrical skeleton branches, whereas the second generation monoliths rather have skeleton branches that resemble a single chain of spherical globules. Using recently established correlations for the flow resistance of cylindrical and globule chain type monolithic structures, it is demonstrated that the higher flow resistance of the second generation monoliths can be entirely attributed to their smaller skeleton sizes, which is also evident from the external porosity that is largely the same for both monolith generations (epsilon(e) similar to 0.65). The recorded van Deemter plots show a clear improvement in efficiency for the second generation monoliths (minimal plate heights of 13.6-14.1 mu m for the first and 6.5-8.2 mu m for the second generation, when assessing the plate count using the Foley-Dorsey method). The corresponding kinetic plots, however, indicate that the much reduced permeability of the second generation monoliths results in kinetic performances (time needed to achieve a given efficiency) which are only better than those of the first generation for plate counts up to N similar to 45,000. For more complex samples (N >= 50,000), the first generation monoliths can intrinsically still provide faster analysis due to their high permeability. It is also demonstrated that - despite the improved efficiency of the second generation monoliths in the practical range of separations (N = 10,000-50,000) - these columns can still not compete with state-of-the-art core-shell particle columns when all columns are evaluated at their own maximum operating pressure (200 bar for the monolithic columns, 600 bar for core-shell columns). It is suggested that monolithic columns will only become competitive with these high efficiency particle columns when further improvements to their production process are made and their pressure resistance is raised. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 82
页数:11
相关论文
共 50 条
  • [21] Chromatographic properties of monolithic silica capillary columns for polar and nonpolar compounds in reversed-phase HPLC
    Kobayashi, H
    Kajiwara, W
    Inui, Y
    Hara, T
    Hosoya, K
    Ikegami, T
    Tanaka, N
    CHROMATOGRAPHIA, 2004, 60 (Suppl 1) : S19 - S25
  • [22] Preparation and Evaluation of Monolithic Silica Capillary Column for Reversed-phase Capillary Liquid Chromatography
    Chen, YaShun
    Jia, Li
    Liu, Wei
    Yi, ZhongZhou
    He, FangFang
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ITS APPLICATION, 2012, 485 : 136 - +
  • [23] Chromatographic Properties of Monolithic Silica Capillary Columns for Polar and Nonpolar Compounds in Reversed-Phase HPLC
    H. Kobayashi
    W. Kajiwara
    Y. Inui
    T. Hara
    K. Hosoya
    T. Ikegami
    N. Tanaka
    Chromatographia, 2004, 60 : S19 - S25
  • [24] Simple and comprehensive two-dimensional reversed-phase HPLC using monolithic silica columns
    Tanaka, N
    Kimura, H
    Tokuda, D
    Hosoya, K
    Ikegami, T
    Ishizuka, N
    Minakuchi, H
    Nakanishi, K
    Shintani, Y
    Furuno, M
    Cabrera, K
    ANALYTICAL CHEMISTRY, 2004, 76 (05) : 1273 - 1281
  • [25] Kinetic performance comparison of superficially porous, fully porous and monolithic reversed-phase columns by gradient kinetic plots for the separation of protein biopharmaceuticals
    Jaag, Simon
    Wen, Chunmei
    Peters, Benjamin
    Lammerhofer, Michael
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1676
  • [26] Effects of pressure and frictional heating on protein separation using monolithic columns in reversed-phase chromatography
    Mann, Benjamin F.
    Makarov, Alexey A.
    Wang, Heather
    Welch, Christopher J.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1489 : 58 - 64
  • [27] Monolithic silica columns for high-efficiency separations by high-performance liquid chromatography
    Ishizuka, N
    Kobayashi, H
    Minakuchi, H
    Nakanishi, K
    Hirao, K
    Hosoya, K
    Ikegami, T
    Tanaka, N
    JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) : 85 - 96
  • [28] THE EFFECT OF THE SILICA SUPPORT OF BONDED REVERSED-PHASE COLUMNS ON CHROMATOGRAPHY OF SOME ANTIBIOTIC COMPOUNDS
    MOATS, WA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 181 - ANYL
  • [29] EFFECT OF THE SILICA SUPPORT OF BONDED REVERSED-PHASE COLUMNS ON CHROMATOGRAPHY OF SOME ANTIBIOTIC COMPOUNDS
    MOATS, WA
    JOURNAL OF CHROMATOGRAPHY, 1986, 366 : 69 - 78
  • [30] An evaluation of the robustness of the Tanaka characterization protocol for reversed-phase liquid chromatography columns
    Petersson, P
    Euerby, MR
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (16) : 2120 - 2129