Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

被引:216
|
作者
Hong, Myeong-Ki
Mintz, Gary S.
Lee, Cheol Whan
Park, Duk-Woo
Choi, Bong-Ryong
Park, Kyoung-Ha
Kim, Young-Hak
Cheong, Sang-Sig
Song, Jae-Kwan
Kim, Jae-Joong
Park, Seong-Wook
Park, Seung-Jung
机构
[1] Univ Ulsan, Coll Med, Dept Med, Asan Med Ctr, Seoul 138736, South Korea
[2] Cardiovasc Res Fdn, New York, NY USA
[3] Univ Ulsan, Coll Med, Dept Med, Asan Med Ctr, Kangnung, South Korea
关键词
ultrasonics; stent; coronary disease;
D O I
10.1093/eurheartj/ehi882
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. Methods and results SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-month follow-up angiography was performed in 449 patients (81.6%) with 543 lesions (81.1%). Clinical, angiographic, procedural, and IVUS predictors of restenosis were determined. Using multivariable logistic regression analysis, the only independent predictors of angiographic restenosis were post-procedural final minimum stent area by IVUS [odds ratio (OR) = 0.586, 95% confidence interval (Cl) 0.387-0.888, P = 0.012] and IVUS-measured stent length (OR = 1.029, 95% Cl 1.002-1.056, P = 0.035). Final minimum stent area by IVUS and IVUS-measured stent length that best separated restenosis from non-restenosis were 5.5 mm(2) and 40 mm, respectively. Lesions with final minimum stent area < 5.5 mm(2) and stent length > 40 mm had the highest rate of angiographic restenosis [17.7% (11/62)], P < 0.001 compared with other groups. Conclusion Independent predictors of angiographic restenosis after SES implantation were post-procedural final minimum stent area by IVUS and IVUS-measured stent length. The angiographic restenosis rate was highest in lesions with stent area < 5.5 mm(2) and stent length > 40 mm.
引用
收藏
页码:1305 / 1310
页数:6
相关论文
共 50 条
  • [31] Late Restenosis of Sirolimus-eluting Stent in the Treatment of In-stent Restenosis of Sirolimus-eluting Stent
    Shibayama, Kentaro
    Kadota, Kazushige
    Tsujimoto, Yuki
    Saito, Naoki
    Miyamoto, Masakazu
    Otsuru, Suguru
    Okamoto, Yoji
    Imai, Masao
    Tasaka, Hiroshi
    Hasegawa, Daiji
    Shigemoto, Yoshikazu
    Habara, Seiji
    Tanaka, Hiroyuki
    Maruo, Takeshi
    Hirono, Akitoshi
    Nishibori, Yosiharu
    Hosogi, Shingo
    Fuku, Yasushi
    Oka, Naoki
    Katoh, Hurumi
    Yamamoto, Hiroyuki
    Fujii, Satoki
    Goto, Tsuyoshi
    Inoue, Katsumi
    Mitsudo, Kazuaki
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 161D - 161D
  • [32] Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis
    Ako, J
    Morino, Y
    Honda, Y
    Hassan, A
    Sonoda, S
    Yock, PG
    Leon, MB
    Moses, JW
    Bonneau, HN
    Fitzgerald, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) : 1002 - 1005
  • [33] No delayed restenosis at 18 months after implantation of sirolimus-eluting stent
    Tanabe, K
    Degertekin, M
    Regar, E
    Ligthart, JMR
    van der Giessen, WJ
    Serruys, PW
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (01) : 65 - 68
  • [34] Sirolimus-eluting stent for treatment of in-stent restenosis: One-year angiographic and intravascular ultrasound follow-up
    Tanabe, K
    Muzaffer, D
    Regar, E
    Lee, CH
    Smits, PC
    van der Giessen, WJ
    de Feyter, P
    Popma, JJ
    Serruys, PW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 12A - 12A
  • [35] Sirolimus-eluting stent implantation for restenosis following brachytherapy
    Hoye, A
    Saia, F
    Degertekin, M
    Lemos, P
    Arampatzis, C
    Tanabe, K
    Lee, C
    Sianos, G
    Smits, PC
    Gissen, W
    deFeyter, P
    Serruys, PW
    vanDomburg, R
    HEART, 2003, 89 : A36 - A37
  • [36] Late Restenosis Following Sirolimus-Eluting Stent Implantation
    Kuriyama, Nehiro
    Kobayashi, Yoshio
    Nakama, Tatsuya
    Mine, Daigo
    Nishihira, Kensaku
    Shimomura, Mitsuhiro
    Nomura, Katsumasa
    Ashikaga, Keiichi
    Matsuyama, Akihiko
    Shibata, Yoshisato
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (01) : 123 - 128
  • [37] Late restenosis following Sirolimus-eluting stent implantation
    Cosgrave, John
    Corbett, Simon J.
    Melzi, Gloria
    Babic, Rade
    Biondi-Zoccai, Giuseppe G. L.
    Airoldi, Flavio
    Chieffo, Alaide
    Sangiorgi, Giuseppe M.
    Montorfano, Matteo
    Michev, Iassen
    Carlino, Mauro
    Colombo, Antonio
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (01): : 41 - 44
  • [38] The reason for the high restenosis rate in sirolimus-eluting stent implantation for hemodialysis patients: An intravascular ultrasound study.
    Suzuki, K.
    Inoue, N.
    Meguro, T.
    Nakanishi, N.
    Shiono, Y.
    Olitsuki, Y.
    Nishibori, Y.
    Mats, A.
    Inoue, K.
    Tanak, T.
    Fujita, H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 54F - 55F
  • [39] Vascular response after overlapping sirolimus-eluting stent implantation: Serial intravascular ultrasound analysis
    Miyazawa, A
    Shimada, Y
    Waseda, K
    Yamasaki, M
    Ako, J
    Morino, Y
    Sudhir, K
    Honda, Y
    Yock, PG
    Fitzgerald, PJ
    CIRCULATION, 2005, 112 (17) : U834 - U834
  • [40] Intravascular ultrasound assessment of optimal stent area to prevent in-stent restenosis after zotarolimus-, everolimus-, and sirolimus-eluting stent implantation
    Song, Hae-Geun
    Kang, Soo-Jin
    Ahn, Jung-Min
    Kim, Won-Jang
    Lee, Jong-Young
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Park, Seong-Wook
    Park, Seung-Jung