From Radon and Thoron Measurements, Inhalation Dose Assessment to National Regulation and Radon Action Plan in Cameroon

被引:6
|
作者
Saidou [1 ,2 ]
Tokonami, Shinji [3 ]
Hosoda, Masahiro [3 ,4 ]
Simo, Augustin [5 ]
Hell, Joseph Victor [1 ]
German, Olga [6 ]
Meless, Esmel Gislere Oscar [7 ]
机构
[1] Inst Geol & Min Res, Res Ctr Nucl Sci & Technol, POB 4110, Yaounde, Cameroon
[2] Univ Yaounde I, Fac Sci, Nucl Phys Lab, Yaounde, Cameroon
[3] Hirosaki Univ, Inst Radiat Emergency Med, Hirosaki, Aomori, Japan
[4] Hirosaki Univ, Dept Radiat Sci, Grad Sch & Hlth Sci, Hirosaki, Aomori, Japan
[5] Natl Radiat Protect Agcy, Yaounde, Cameroon
[6] IAEA, Dept Nucl Safety & Secur, Vienna, Austria
[7] IAEA, Dept Tech Cooperat, Vienna, Austria
来源
JOURNAL OF RADIATION PROTECTION AND RESEARCH | 2022年 / 47卷 / 04期
关键词
Radon; Thoron; Inhalation Dose; Reference Level; Radon Regulation; Radon Action Plan; RADIONUCLIDES;
D O I
10.14407/jrpr.2021.00213
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: The current study reports measurements of activity concentrations of radon (Rn-222) and thoron (Rn-220) in dwellings, followed by inhalation dose assessment of the public, and then by the development of regulation and the national radon action plan (NRAP) in Cameroon. Materials and Methods: Radon, thoron, and thoron progeny measurements were carried out from 2014 to 2017 using radon-thoron discriminative detectors (commercially RADUET) in 450 dwellings and thoron progeny monitors in 350 dwellings. From 2019 to 2020, radon track detectors (commercially RADTRAK) were deployed in 1,400 dwellings. It was found that activity concentrations of radon range in 1,850 houses from 10 to 2,620 Bq/m(3) with a geometric mean of 76 Bq/m(3). Results and Discussion: Activity concentrations of thoron range from 20 to 700 Bq/m(3) with a geometric mean of 107 Bq/m(3). Thoron equilibrium factor ranges from 0.01 to 0.6, with an arithmetic mean of 0.09 that is higher than the default value of 0.02 given by UNSCEAR. On average, 49%, 9%, and 2% of all surveyed houses have radon concentrations above 100, 200, and 300 Bq/m(3), respectively. The average contribution of thoron to the inhalation dose due to radon and thoron exposure is about 40%. Thus, thoron cannot be neglected in dose assessment to avoid biased results in radio-epidemiological studies. Only radon was considered in the drafted regulation and in the NRAP adopted in October 2020. Reference levels of 300 Bq/m(3) and 1,000 Bq/m(3) were recommended for dwellings and workplaces. Conclusion: Priority actions for the coming years include the following: radon risk mapping, promotion of a protection policy against radon in buildings, integration of the radon prevention and mitigation into the training of construction specialists, mitigation of dwellings and workplaces with high radon levels, increased public awareness of the health risks associated with radon, and development of programs on the scientific and technical aspects.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [31] Relevance of radon progeny measurements for the assessment of inhalation doses in groundwater utilities
    Tyrvainen, Jukka T.
    Naarala, Jonne
    Turtiainen, Tuukka
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [32] Radon and thoron concentrations in the southwest region of Angola: dose assessment and implications for risk mapping
    Edson Baptista
    Alcides J. S. C. Pereira
    Filipa P. Domingos
    Sérgio L. R. Sêco
    Environmental Geochemistry and Health, 2023, 45 : 665 - 686
  • [33] DOSE TO RED BONE-MARROW FROM NATURAL RADON AND THORON EXPOSURE
    RICHARDSON, RB
    EATOUGH, JP
    HENSHAW, DL
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (763): : 608 - 624
  • [34] Dose estimation derived from the exposure to radon, thoron and their progeny in the indoor environment
    Ramola, R. C.
    Prasad, Mukesh
    Kandari, Tushar
    Pant, Preeti
    Bossew, Peter
    Mishra, Rosaline
    Tokonami, S.
    SCIENTIFIC REPORTS, 2016, 6
  • [35] Dose estimation derived from the exposure to radon, thoron and their progeny in the indoor environment
    R. C. Ramola
    Mukesh Prasad
    Tushar Kandari
    Preeti Pant
    Peter Bossew
    Rosaline Mishra
    S. Tokonami
    Scientific Reports, 6
  • [36] Measurement of tracheobronchial dose from simultaneous exposure to environmental radon and thoron progeny
    Yu, KN
    Guan, ZJ
    Young, ECM
    Stokes, MJ
    HEALTH PHYSICS, 1998, 75 (02): : 153 - 158
  • [37] Inhalation dose from exposure to radon, thoron and their progeny in indoors around a nuclear power generation facility in Uttar Pradesh, India
    Kumar, Mukesh
    Kumar, Pankaj
    Agrawal, Anshu
    Sahoo, B. K.
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (02) : 316 - 328
  • [38] Assessment of Radiological Risks due to Indoor Radon, Thoron and Progeny, and Soil Gas Radon in Thorium-Bearing Areas of the Centre and South Regions of Cameroon
    Serge, Atangana Bingana Martin
    Didier, Takoukam Soh Serge
    Samuel, Bineng Guillaume
    Kranrod, Chutima
    Omori, Yasutaka
    Hosoda, Masahiro
    Saidou
    Tokonami, Shinji
    ATMOSPHERE, 2023, 14 (12)
  • [39] Radon and thoron exhalation rate measurements from building materials used in Serbia
    Celikovic, Igor T.
    Pantelic, Gordana K.
    Zivanovic, Milos Z.
    Vukanac, Ivana S.
    Nikolic, Jelena D. Krneta
    Kandic, Aleksandar B.
    Loncar, Boris B.
    NUKLEONIKA, 2020, 65 (02) : 111 - 114
  • [40] Dose and risk assessment from radon in the ural
    Zhukovsky, M
    Yarmoshenko, I
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B302 - B304