From Radon and Thoron Measurements, Inhalation Dose Assessment to National Regulation and Radon Action Plan in Cameroon

被引:6
|
作者
Saidou [1 ,2 ]
Tokonami, Shinji [3 ]
Hosoda, Masahiro [3 ,4 ]
Simo, Augustin [5 ]
Hell, Joseph Victor [1 ]
German, Olga [6 ]
Meless, Esmel Gislere Oscar [7 ]
机构
[1] Inst Geol & Min Res, Res Ctr Nucl Sci & Technol, POB 4110, Yaounde, Cameroon
[2] Univ Yaounde I, Fac Sci, Nucl Phys Lab, Yaounde, Cameroon
[3] Hirosaki Univ, Inst Radiat Emergency Med, Hirosaki, Aomori, Japan
[4] Hirosaki Univ, Dept Radiat Sci, Grad Sch & Hlth Sci, Hirosaki, Aomori, Japan
[5] Natl Radiat Protect Agcy, Yaounde, Cameroon
[6] IAEA, Dept Nucl Safety & Secur, Vienna, Austria
[7] IAEA, Dept Tech Cooperat, Vienna, Austria
来源
JOURNAL OF RADIATION PROTECTION AND RESEARCH | 2022年 / 47卷 / 04期
关键词
Radon; Thoron; Inhalation Dose; Reference Level; Radon Regulation; Radon Action Plan; RADIONUCLIDES;
D O I
10.14407/jrpr.2021.00213
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: The current study reports measurements of activity concentrations of radon (Rn-222) and thoron (Rn-220) in dwellings, followed by inhalation dose assessment of the public, and then by the development of regulation and the national radon action plan (NRAP) in Cameroon. Materials and Methods: Radon, thoron, and thoron progeny measurements were carried out from 2014 to 2017 using radon-thoron discriminative detectors (commercially RADUET) in 450 dwellings and thoron progeny monitors in 350 dwellings. From 2019 to 2020, radon track detectors (commercially RADTRAK) were deployed in 1,400 dwellings. It was found that activity concentrations of radon range in 1,850 houses from 10 to 2,620 Bq/m(3) with a geometric mean of 76 Bq/m(3). Results and Discussion: Activity concentrations of thoron range from 20 to 700 Bq/m(3) with a geometric mean of 107 Bq/m(3). Thoron equilibrium factor ranges from 0.01 to 0.6, with an arithmetic mean of 0.09 that is higher than the default value of 0.02 given by UNSCEAR. On average, 49%, 9%, and 2% of all surveyed houses have radon concentrations above 100, 200, and 300 Bq/m(3), respectively. The average contribution of thoron to the inhalation dose due to radon and thoron exposure is about 40%. Thus, thoron cannot be neglected in dose assessment to avoid biased results in radio-epidemiological studies. Only radon was considered in the drafted regulation and in the NRAP adopted in October 2020. Reference levels of 300 Bq/m(3) and 1,000 Bq/m(3) were recommended for dwellings and workplaces. Conclusion: Priority actions for the coming years include the following: radon risk mapping, promotion of a protection policy against radon in buildings, integration of the radon prevention and mitigation into the training of construction specialists, mitigation of dwellings and workplaces with high radon levels, increased public awareness of the health risks associated with radon, and development of programs on the scientific and technical aspects.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [21] Reducing the inhalation dose from radon decay products
    Larsson, Laura S.
    Kladder, Doug
    SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 450 : 374 - 374
  • [22] Reducing the inhalation dose from radon decay products
    Tschiersch, Jochen
    Meisenberg, Oliver
    Wang, Jin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 435 : 578 - 579
  • [23] DOSE TO LUNG AND OTHER ORGANS FROM RADON AND THORON AS A FUNCTION OF AGE
    MILES, JCH
    CLIFF, KD
    RADIATION PROTECTION DOSIMETRY, 1992, 41 (2-4) : 251 - 253
  • [24] The Importance of Direct Progeny Measurements for Correct Estimation of Effective Dose Due to Radon and Thoron
    Bineng, Guillaume Samuel
    Saidou
    Tokonami, Shinji
    Hosoda, Masahiro
    Siaka, Yvette Flore Tchuente
    Issa, Hamadou
    Suzuki, Takahito
    Kudo, Hiromi
    Bouba, Oumarou
    FRONTIERS IN PUBLIC HEALTH, 2020, 8
  • [25] Radon-thoron discriminative measurements in Gansu province, China, and their implication for dose estimates
    Yamada, Y
    Sun, QF
    Tokonami, S
    Akiba, S
    Zhou, WH
    Hou, CS
    Zhang, SZ
    Ishikawa, T
    Furukawa, M
    Fukutsu, K
    Yonehara, H
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2006, 69 (7-8): : 723 - 734
  • [26] Assessment of radon equilibrium factor from distribution parameters of simultaneous radon and radon progeny measurements
    Chen, Jing
    Marro, Leonora
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2011, 50 (04) : 597 - 601
  • [27] Assessment of radon equilibrium factor from distribution parameters of simultaneous radon and radon progeny measurements
    Jing Chen
    Leonora Marro
    Radiation and Environmental Biophysics, 2011, 50 : 597 - 601
  • [28] Indoor radon and thoron from building materials: Analysis of humidity, air exchange rate, and dose assessment
    Syuryavin, Ahmad Ciptadi
    Park, Seongjin
    Nirwono, Muttaqin Margo
    Lee, Sang Hoon
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (10) : 2370 - 2378
  • [29] Radon and thoron concentrations in the southwest region of Angola: dose assessment and implications for risk mapping
    Baptista, Edson
    Pereira, Alcides J. S. C.
    Domingos, Filipa P.
    Seco, Sergio L. R.
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2023, 45 (03) : 665 - 686
  • [30] ANNUAL EFFECTIVE DOSE ASSESSMENT DUE TO RADON AND THORON PROGENIES IN DWELLINGS OF KILIMAMBOGO, KENYA
    Nyambura, C.
    Tokonami, S.
    Hashim, N. O.
    Chege, M. W.
    Suzuki, T.
    Kudo, H.
    Hosoda, M.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (3-4) : 430 - 434