Effects of natural organic matter (NOM) character and removal on ozonation for maximizing disinfection with minimum bromate and AOC formation

被引:7
作者
van der Helm, A. W. C. [1 ,2 ]
Grefte, A. [2 ]
Baars, E. T. [1 ]
Rietveld, L. C. [2 ]
van Dijk, J. C. [2 ]
Amy, G. L. [3 ]
机构
[1] Waternet, NL-1005 AD Amsterdam, Netherlands
[2] Delft Univ Technol, NL-2600 GA Delft, Netherlands
[3] UNESCO, IHE, Inst Water Educ, NL-2601 DA Delft, Netherlands
来源
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA | 2009年 / 58卷 / 06期
关键词
AOC; bromate; disinfection; NOM; ozone; SEC-DOC; SUVA; ANION-EXCHANGE RESIN; BY-PRODUCT FORMATION; DRINKING-WATER; OZONE DECOMPOSITION; ACTIVATED CARBON; WASTE-WATER; OXIDATION; FILTRATION; EFFICIENCY; PHASE;
D O I
10.2166/aqua.2009.143
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this study was to evaluate the effects of the character and the removal of natural organic matter (NOM) on the formation of assimilable organic carbon (AOC) and bromate during ozone disinfection. Natural waters from two locations with different dissolved organic carbon (DOC) concentrations were tested. In addition, the DOC concentration of one of the natural waters was reduced either by ion exchange (IEX) or by granular activated carbon (GAC) filtration. The resulting four water types were tested in conventional pilot-scale ozone bubble column reactors and in a bench-scale plug flow reactor with dissolved ozone dosing. For the tested waters NOM fractions were determined with size exclusion chromatography using DOC and UVA(254) detection. As expected, it was observed that for the same ozone dosages the CT is higher when NOM is removed by IEX or GAC compared to the situation without NOM removal. It is concluded that, for the waters tested, removal of the humic compounds with a molecular weight of approximately 1,000 g/mol by using IEX led to less AOC formation and less bromate formation as compared to the removal of humic compounds with a molecular weight of 300-500 g/mol by using GAC.
引用
收藏
页码:373 / 385
页数:13
相关论文
共 27 条
  • [11] GILBERT E, 1981, GWF WASSER ABWASSER, V122, P410
  • [12] CHARACTERIZATION OF WATER-QUALITY CRITERIA FOR OZONATION PROCESSES .2. LIFETIME OF ADDED OZONE
    HOIGNE, J
    BADER, H
    [J]. OZONE-SCIENCE & ENGINEERING, 1994, 16 (02) : 121 - 134
  • [13] A NEW METHOD FOR THE CHARACTERIZATION OF ORGANIC-CARBON IN AQUATIC SYSTEMS
    HUBER, SA
    FRIMMEL, FH
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 49 (1-2) : 49 - 57
  • [14] HUBER SA, 1996, WASSER, V86, P277
  • [15] Langlais B., 1991, Ozone in Water Treatment: Application and Engineering
  • [16] Principles of gas absorption
    Lewis, WK
    Whitman, WG
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1924, 16 : 1215 - 1220
  • [17] Orlandini E, 1997, J WATER SUPPLY RES T, V46, P20
  • [18] Integrated simulation of drinking water treatment
    Rietveld, Luuk
    van der Helm, Alex
    van Schagen, Kim
    van der Aa, Rene
    van Dijk, Hans
    [J]. JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2008, 57 (03): : 133 - 141
  • [19] Modeling hydrodynamics and mass transfer parameters in a continuous ozone bubble column
    Roustan, M
    Wang, RY
    Wolbert, D
    [J]. OZONE-SCIENCE & ENGINEERING, 1996, 18 (02) : 99 - 115
  • [20] ROUSTAN M, 1987, OZONE-SCI ENG, V9, P289