A solid-phase extraction method for phenols in landfill leachates was developed and optimized in order to solve the expected and observed problems associated with an anaerobic matrix containing high concentrations of salts and organic matter. Isolute ENV+ cartridges exhibited the best retention of phenols of the four sorbents examined, and was the only cartridge which a 1 L leachate sample could pass through. With the other cartridges, clogging made this impossible. The final method, which included 27 different phenols, gave detection limits of <0.1 mug/L (drinking water concentration limit for pesticides) for most phenols (25), and for 12 phenols <0.01 mug/L. Recovery rates (determined for four concentrations in the range 1-25 mug/L, two replicates of each) were in the range 79-104% (SD 1-12%), except for phenol (26 +/- 1.3%) and 2-methoxyphenol (62 +/- 4.2%). Up to 12 different phenols could be identified in leachates from three Danish landfills, ranging in concentration from 0.01 to 29 mug/L, which is at the lower end of the concentration range usually found for phenols in landfill leachates (sub-mug/L to mg/L). (C) 2002 Elsevier Science B.V. All rights reserved.