Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size

被引:16
|
作者
Kawashima, Hiroki [1 ]
Ichikawa, Katsuhiro [1 ]
Hanaoka, Shinsuke [2 ]
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, Kanazawa, Ishikawa, Japan
[2] Kanazawa Univ Hosp, Radiol Div, Kanazawa, Ishikawa, Japan
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 04期
基金
日本学术振兴会;
关键词
auto exposure control; computed tomography; contrast-to-noise ratio; image quality; patient size; size-specific dose estimates; AUTOMATIC EXPOSURE CONTROL; TUBE CURRENT MODULATION; PEDIATRIC CT; PHANTOM; OPTIMIZATION; MDCT; VOLTAGE; SYSTEMS; LIVER;
D O I
10.1002/acm2.12340
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigates the relationship between contrast-to-noise ratio (CNR) and size-specific dose estimate (SSDE) in computed tomography (CT) depending on patient size. In addition, the relationship to the auto exposure control (AEC) techniques is examined. A tissue-equivalent material having human-liver energy dependence is developed and used to evaluate these relationships. Three exposure dose levels (constant CT dose index, constant SSDE, and with AEC) are tested using four different phantom sizes (diameter: 15, 20, 25 and 30cm) in two different CT scanners (SOMATOM Definition Flash, Siemens, and LightSpeed VCT, GE). The contrast-to-noise ratios (CNRs) are measured using the developed phantom. It is found that the CNR increases with decreasing phantom size at constant SSDE, although the increase ratio is smaller than that of the constant CT dose index. This result indicates that the image characteristics differ even when the patient dose received from the CT examination is equivalent for each patient size. In the case of AEC use, the CNR results of the Siemens scanner exhibit a similar trend to those obtained for constant SSDE, for each phantom size. This suggests that the AEC technique that maintains a constant image quality (CARE Dose 4D) for each patient size corresponds well to the image quality obtained for constant SSDE. These findings facilitate further understanding of the relationship between image quality and exposure CT dose depending on patient size.
引用
收藏
页码:246 / 251
页数:6
相关论文
共 50 条
  • [41] Local diagnostic reference level based on size-specific dose estimates: Assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children’s hospital
    Rumi Imai
    Osamu Miyazaki
    Tetsuya Horiuchi
    Hideo Kurosawa
    Shunsuke Nosaka
    Pediatric Radiology, 2015, 45 : 345 - 353
  • [42] Local diagnostic reference level based on size-specific dose estimates: Assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children's hospital
    Imai, Rumi
    Miyazaki, Osamu
    Horiuchi, Tetsuya
    Kurosawa, Hideo
    Nosaka, Shunsuke
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 345 - 353
  • [43] LOCAL DRLS FOR PAEDIATRIC CT EXAMINATIONS BASED ON SIZE-SPECIFIC DOSE ESTIMATES IN KERMANSHAH, IRAN
    Mohammadbeigi, Ahmad
    Khoshgard, Karim
    Haghparast, Abbas
    Eivazi, Mohammad Taghi
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (04) : 496 - 506
  • [44] Image quality and dose in spiral computed tomography
    Verdun, FR
    Meuli, RA
    Bochud, FO
    Imsand, C
    Raimondi, S
    Schnyder, P
    Valley, JF
    EUROPEAN RADIOLOGY, 1996, 6 (04) : 485 - 488
  • [45] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1814 - 1822
  • [46] Size-specific, scanner-independent organ dose estimates in contiguous axial and helical head CT examinations
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Chris
    Zankl, Maria
    Sepahdari, Ali R.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2014, 41 (12)
  • [47] PATIENTS DOSE ESTIMATION IN CT EXAMINATIONS USING SIZE SPECIFIC DOSE ESTIMATES
    Choudhary, Neha
    Rana, Bhupendra Singh
    Shukla, Arvind
    Oinam, Arun Singh
    Singh, Narinder Paul
    Kumar, Sanjeev
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) : 256 - 262
  • [48] A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Dougherty, G.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [49] A simple manual method to estimate water-equivalent diameter for calculating size-specific dose estimate in chest computed tomography
    Mihailidis, Dimitris
    Tsapaki, Virginia
    Tomara, Pelagia
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1117)
  • [50] Tailoring CT Dose to Patient Size: Implementation of the Updated 2017 ACR Size-specific Diagnostic Reference Levels
    Klosterkemper, Yan
    Appel, Elisabeth
    Thomas, Christoph
    Bethge, Oliver T.
    Aissa, Joel
    Kroepil, Patric
    Antoch, Gerald
    Boos, Johannes
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1624 - 1631