Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size

被引:16
|
作者
Kawashima, Hiroki [1 ]
Ichikawa, Katsuhiro [1 ]
Hanaoka, Shinsuke [2 ]
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, Kanazawa, Ishikawa, Japan
[2] Kanazawa Univ Hosp, Radiol Div, Kanazawa, Ishikawa, Japan
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 04期
基金
日本学术振兴会;
关键词
auto exposure control; computed tomography; contrast-to-noise ratio; image quality; patient size; size-specific dose estimates; AUTOMATIC EXPOSURE CONTROL; TUBE CURRENT MODULATION; PEDIATRIC CT; PHANTOM; OPTIMIZATION; MDCT; VOLTAGE; SYSTEMS; LIVER;
D O I
10.1002/acm2.12340
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigates the relationship between contrast-to-noise ratio (CNR) and size-specific dose estimate (SSDE) in computed tomography (CT) depending on patient size. In addition, the relationship to the auto exposure control (AEC) techniques is examined. A tissue-equivalent material having human-liver energy dependence is developed and used to evaluate these relationships. Three exposure dose levels (constant CT dose index, constant SSDE, and with AEC) are tested using four different phantom sizes (diameter: 15, 20, 25 and 30cm) in two different CT scanners (SOMATOM Definition Flash, Siemens, and LightSpeed VCT, GE). The contrast-to-noise ratios (CNRs) are measured using the developed phantom. It is found that the CNR increases with decreasing phantom size at constant SSDE, although the increase ratio is smaller than that of the constant CT dose index. This result indicates that the image characteristics differ even when the patient dose received from the CT examination is equivalent for each patient size. In the case of AEC use, the CNR results of the Siemens scanner exhibit a similar trend to those obtained for constant SSDE, for each phantom size. This suggests that the AEC technique that maintains a constant image quality (CARE Dose 4D) for each patient size corresponds well to the image quality obtained for constant SSDE. These findings facilitate further understanding of the relationship between image quality and exposure CT dose depending on patient size.
引用
收藏
页码:246 / 251
页数:6
相关论文
共 50 条
  • [21] Size-Specific Dose Estimates Based on Water-Equivalent Diameter and Effective Diameter in Computed Tomography Coronary Angiography
    Xu, Jian
    Wang, Xiangquan
    Xiao, Huawei
    Xu, Jianguo
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9299 - 9305
  • [22] Evolved size-specific dose estimates for patient-specific organ doses from chest CT scans based on hybrid patient size vectors
    Shao, Wencheng
    Yang, Ke
    Lou, Lizhi
    Lin, Xin
    Qu, Liangyong
    Zhuo, Weihai
    Liu, Haikuan
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2025,
  • [23] Volume computed tomography dose index (CTDIvol) and size-specific dose estimate (SSDE) for tube current modulation (TCM) in CT scanning
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I
    Dougherty, G.
    McLean, D.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (03): : 289 - 297
  • [24] Patient-specific organ and effective dose estimates in pediatric oncology computed tomography
    Gao, Yiming
    Quinn, Brian
    Pandit-Taskar, Neeta
    Behr, Gerald
    Mahmood, Usman
    Long, Daniel
    Xu, X. George
    St.Germain, Jean
    Dauer, Lawrence T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 146 - 155
  • [25] Improved patient size estimates for accurate dose calculations in abdomen computed tomography
    Chang-Lae Lee
    Journal of the Korean Physical Society, 2017, 71 : 116 - 120
  • [26] Improved Patient Size Estimates for Accurate Dose Calculations in Abdomen Computed Tomography
    Lee, Chang-Lae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (02) : 116 - 120
  • [27] Analysis of size-specific dose profiles beyond the scan range in water phantoms undergoing computed tomography examinations
    Masoudi, M.
    Faghihi, R.
    Sina, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 551 - 557
  • [28] From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting
    Hu, Liwei
    Ouyang, Rongzhen
    Li, Jing
    Zhang, Guozhi
    Li, Jiong
    Guo, Chen
    Wang, Qian
    Zhong, Yumin
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (20) : 1981 - 1989
  • [29] Size-specific dose estimates for various weighting factors of CTDI equation
    Haba, Tomonobu
    Kobayashi, Masanao
    Koyama, Shuji
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (01) : 155 - 162
  • [30] Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
    Sulemana, Hamza
    Mumuni, Abdul Nashirudeen
    Abubakari, Izre-deen Osman Mohammed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):