Discharge and Plasma Characteristics of Pulse-Enhanced Vacuum Arc Evaporation (PEVAE) for Titanium Cathode

被引:10
作者
Ma, Yinghe [1 ]
Gong, Chunzhi [1 ]
Tian, Qinwen [2 ]
Chu, Paul K. [3 ]
Golosov, Dmitriy A. [4 ]
Tian, Xiubo [1 ]
机构
[1] Harbin Inst Technol, State Key Lab Adv Welding & Joining, Harbin 150001, Heilongjiang, Peoples R China
[2] Jiamusi Univ, Sch Mat Sci & Engn, Jiamusi 154007, Peoples R China
[3] City Univ Hong Kong, Dept Phys & Mat Sci, Hong Hom, Hong Kong, Peoples R China
[4] Belarusian State Univ Informat & Radioelect, Thin Film Res Lab, Minsk 220013, BELARUS
关键词
Electron emission; optical emission spectra; pulse-enhanced vacuum arc evaporation (PEVAE); substrate current; vacuum arc; OPTICAL-EMISSION SPECTROSCOPY; CURRENT-DENSITY; DEPOSITION; PARAMETERS; PRESSURE; GAS; DISTRIBUTIONS; DEPENDENCE; COATINGS; TIN;
D O I
10.1109/TPS.2018.2801333
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
This paper reports experimental investigation of the discharge behavior of pulse-enhanced vacuum arc evaporation (PEVAE) with titanium target. The PEVAE discharge was analyzed by optical emission spectroscopy, monitoring of substrate current and the electron probe current at different N-2 pressure or arc current, respectively, compared to that of conventional dc arc. The results show that during the PEVAE process the electron probe current was significantly enhanced particularly at a higher pulsed current. An increase of up to more than 1-2 times was observed. Electron emission was substantially enhanced. The substrate current increased linearly with arc current regardless of the dc or PEVAE mode; however, the latter led to a larger current-rise slope. The substrate current with the PEVAE mode was improved to over 7 times. The optical emission spectra of plasma at nitrogen atmosphere showed that the intensities of ion species (e.g., Ti2+, Ti+, N+, N-2(+)) gradually increased with pulsed arc current for the PEVAE mode. Electron temperature derived from Ti+ ion spectra was 0.55-0.6 eV and changed slightly in the PEVAE mode or dc mode. The increase in plasma spectral intensity is caused by the plasma density increase from larger ion density. These results imply that PEVAE may be an effective technique for film deposition of better microstructure and properties due to higher substrate current induced by larger electron emission and plasma density.
引用
收藏
页码:2619 / 2625
页数:7
相关论文
共 37 条
[1]  
Aksenov II, 1998, P INT SYMP DISCH EL, V18, P577, DOI 10.1109/DEIV.1998.738729
[2]  
Anders A, 2008, SPRINGER SER ATOM OP, V50, P363, DOI 10.1007/978-0-387-79108-1_8
[3]   TIME-DEPENDENCE OF VACUUM-ARC PARAMETERS [J].
ANDERS, A ;
ANDERS, S ;
JUTTNER, B ;
BROWN, IG .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1993, 21 (03) :305-311
[4]   Ion charge state distributions of pulsed vacuum arcs - Interpretation of their temporal development [J].
Anders, A .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1998, 26 (01) :118-119
[5]   BRIGHTNESS DISTRIBUTION AND CURRENT-DENSITY OF VACUUM-ARC CATHODE SPOTS [J].
ANDERS, S ;
ANDERS, A ;
JUTTNER, B .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1992, 25 (11) :1591-1599
[6]   Study of TiN and ZrN thin films grown by cathodic arc technique [J].
Arias, D. F. ;
Arango, Y. C. ;
Devia, A. .
APPLIED SURFACE SCIENCE, 2006, 253 (04) :1683-1690
[7]   ION FLUX CHARACTERISTICS IN ARC VAPOR-DEPOSITION OF TIN [J].
BERGMAN, C .
SURFACE & COATINGS TECHNOLOGY, 1988, 36 (1-2) :243-255
[8]   Influence of gas pressure and cathode composition on ion energy distributions in filtered cathodic vacuum arcs [J].
Bilek, MMM ;
Martin, PJ ;
McKenzie, DR .
JOURNAL OF APPLIED PHYSICS, 1998, 83 (06) :2965-2970
[9]   Time-resolved Langmuir probe measurements at the substrate position in a pulsed mid-frequency DC magnetron plasma [J].
Bradley, JW ;
Bäcker, H ;
Kelly, PJ ;
Arnell, RD .
SURFACE & COATINGS TECHNOLOGY, 2001, 135 (2-3) :221-228
[10]  
Cheng ZY, 1996, ISDEIV - XVIITH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, VOLS I AND II, P858, DOI 10.1109/DEIV.1996.545484