Epitope imprinting of alpha-synuclein for sensing in Parkinson's brain organoid culture medium

被引:31
作者
Lee, Mei-Hwa [1 ]
Thomas, James L. [2 ]
Su, Zi-Lin [3 ]
Yeh, Wen-Kuan [4 ,5 ]
Monzel, Anna S. [6 ]
Bolognin, Silvia [6 ]
Schwamborn, Jens C. [6 ]
Yang, Chien-Hsin [3 ]
Lin, Hung-Yin [3 ]
机构
[1] I Shou Univ, Dept Mat Sci & Engn, Kaohsiung 84001, Taiwan
[2] Univ New Mexico, Dept Phys & Astron, Albuquerque, NM 87131 USA
[3] Natl Univ Kaohsiung, Dept Chem & Mat Engn, Kaohsiung 81148, Taiwan
[4] Natl Univ Kaohsiung, Dept Elect Engn, Kaohsiung 81148, Taiwan
[5] Taiwan Semicond Res Inst, Hsinchu 30009, Taiwan
[6] Univ Luxembourg, Luxembourg Ctr Syst Biomed LCSB, L-4367 Belvaux, Luxembourg
关键词
Alpha-synuclein; Epitope imprinting; Electrochemical sensing; Human patient specific brain organoids; ELECTROCHEMICAL POLYMERIZATION; POLYMERS; POTENTIOSTAT; SENSOR;
D O I
10.1016/j.bios.2020.112852
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Parkinson's disease (PD) is a progressive nervous system disorder that affects movement, whose early signs may be mild and unnoticed. alpha-Synuclein has been identified as the major component of Lewy bodies and Lewy neurites, which are the characteristic proteinaceous deposits that are the hallmarks of PD. In this work, three alpha-synuclein peptides were synthesized as templates for the molecular imprinting of conductive polymers to enable recognition of alpha-synuclein via ultrasensitive electrochemical measurements. The peptide sequences encompassed specific residues where mutations are known to accelerate PD (though the target sequences, in this study, were wild-type.) The different peptide targets were all successfully imprinted, but with differing imprinting effectiveness, probably owing to differences in target carboxylic acids (which can bind to the aniline (AN) m-aminobenzenesulfonic acid (MSAN) MIP polymers.) Composition of the imprinted polymer, (the mole proportions of AN and MSAN), and the concentrations and sequences of imprinted peptide templates were optimized by measuring the electrochemical responses to target peptides. The imprinted electrode can detect alpha-synuclein at fg/mL levels, and was therefore used to measure alpha-synuclein in the culture medium of human brain organoids generated from normal and idiopathic PD patients.
引用
收藏
页数:9
相关论文
共 37 条
[1]   Label-Free Detection of Tear Biomarkers Using Hydrogel-Coated Gold Nanoshells in a Localized Surface Plasmon Resonance-Based Biosensor [J].
Culver, Heidi R. ;
Wechsler, Marissa E. ;
Peppas, Nicholas A. .
ACS NANO, 2018, 12 (09) :9342-9354
[2]  
DeMaagd George, 2015, P T, V40, P504
[3]   Detection of Parkinson's Disease through the Peptoid Recognizing α-Synuclein in Serum [J].
Gao, Houqian ;
Zhao, Zijian ;
He, Zhaohui ;
Wang, Huayi ;
Liu, Mingzhu ;
Hu, Zhiyuan ;
Cheng, Oumei ;
Yang, Yanlian ;
Zhu, Ling .
ACS CHEMICAL NEUROSCIENCE, 2019, 10 (03) :1204-1208
[4]   An epitope-imprinted piezoelectric diagnostic tool for Neisseria meningitidis detection [J].
Gupta, Neha ;
Shah, Kavita ;
Singh, Meenakshi .
JOURNAL OF MOLECULAR RECOGNITION, 2016, 29 (12) :572-579
[5]   SYNTHESIS AND PROPERTIES OF ELECTRICALLY CONDUCTING POLYMERS FROM AROMATIC-AMINES [J].
HAGIWARA, T ;
DEMURA, T ;
IWATA, K .
SYNTHETIC METALS, 1987, 18 (1-3) :317-322
[6]   Integrated potentiostat for electrochemical sensing of urinary 3-hydroxyanthranilic acid with molecularly imprinted poly (ethylene-co-vinyl alcohol) [J].
Huang, Chun-Yueh ;
O'Hare, Danny ;
Chao, I-Jen ;
Wei, Hung-Wei ;
Liang, Yi-Fan ;
Liu, Bin-Da ;
Lee, Mei-Hwa ;
Lin, Hung-Yin .
BIOSENSORS & BIOELECTRONICS, 2015, 67 :208-213
[7]   Urinalysis with molecularly imprinted poly(ethylene-co-vinyl alcohol) potentiostat sensors [J].
Huang, Chun-Yueh ;
Tsai, Tain-Chin ;
Thomas, James L. ;
Lee, Mei-Hwa ;
Liu, Bin-Da ;
Lin, Hung-Yin .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) :2611-2617
[8]   Conducting Polymers in the Fields of Energy, Environmental Remediation, and Chemical-Chiral Sensors [J].
Ibanez, Jorge G. ;
Rincon, Marina. E. ;
Gutierrez-Granados, Silvia ;
Chahma, M'hamed ;
Jaramillo-Quintero, Oscar A. ;
Frontana-Uribe, Bernardo A. .
CHEMICAL REVIEWS, 2018, 118 (09) :4731-4816
[9]   α-Synuclein Oligomer Detection with Aptamer Switch on Reduced Graphene Oxide Electrode [J].
Jang, Seung Joo ;
Lee, Chang-Seuk ;
Kim, Tae Hyun .
NANOMATERIALS, 2020, 10 (05)
[10]  
Lattach Y., 2011, DEV CHARACTERIZATION