Insertion depth of left-sided double-lumen endobroncheal tube: A new predictive formula

被引:5
作者
Eldawlatly, Abdelazeem [1 ]
Alqatari, Ahmed [1 ]
Kanchi, Naveed [1 ]
Marzouk, Amir [1 ,2 ]
机构
[1] King Saud Univ, Coll Med, Dept Anesthesia, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Med, Res Ctr, Riyadh, Saudi Arabia
关键词
Double-lumen tube; insertion depth; thoracic anesthesia; PLACEMENT; HEIGHT;
D O I
10.4103/sja.SJA_809_18
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: In the field of thoracic anesthesia, it is well-established practice that the insertion depth of left-sided double-lumen tube (LDLT) is achieved after checking its position via fiberoptic bronchoscopy (FOB). Several studies have shown positive correlation between body height (BH) and the optimal insertion depth of a LDLT. Each of these studies has developed a formula for proper insertion depth of the LDLT. In this study, we prospectively studied our patients whose tracheas were intubated correctly with LDLT using FOB confirmation and examined the optimal insertion depth of LDLT aiming at finding a formula suitable for our patients. Methods: After obtaining the institutional review board approval of College of Medicine Research Centre, King Saud University, we recruited 41 adult patients who underwent thoracic surgery with one-lung ventilation (OLV). The study included patients whose procedure required placement of a LDLT. The optimal insertion depth of the LDLT was confirmed using FOB. The following variables were recorded, the patient's sex, age, BH, and the final correct insertion depth of the LDLT (cm) measured from the corner of the mouth. The results of LDLT insertion depth in our study were compared to another published five studies. Statistical analysis was performed using Statistical Package for the Social Sciences (SPSS) version 22 software (SPSS Inc., Chicago, IL, USA). Results: Positive correlation was found between BH (cm) and insertion depth of LDLT (cm) since r = 0.744 (P < 0.05). Also, positive correlation was found between the LDLT size (Fr) and insertion depth of LDLT (cm) since r = 0.792 (P < 0.05) where r is Pearson's correlation coefficient. By fit curve (Curve Estimation), we were able to get the predicted equation for our cases as follow: the insertion depth of LDLT (cm) = 0.249 x (BH)(0.916) with significant correlation to the other five formulae (P < 0.05). Conclusion: In the present study we have obtained a novel formula to predict the insertion depth of LDLT. Currently we are conducting a verification study on a larger sample size to attest its validity. However at this stage and till the results are released we cannot judge on it. We believe time will tell about the validity of our formula for our patients.
引用
收藏
页码:227 / 230
页数:4
相关论文
共 15 条
[1]   A randomized trial to assess the utility of preintubation adult fiberoptic bronchoscope assessment in patients for thoracic surgery requiring one - lung ventilation [J].
Amin, Nayana ;
Tarwade, Pritee ;
Shetmahajan, Madhavi ;
Pramesh, C. S. ;
Jiwnani, Sabita ;
Mahajan, Abhishek ;
Purandare, Nilendu .
ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (02) :251-255
[2]   Prediction of double-lumen tracheal tube depth [J].
Bahk, JH ;
Oh, YS .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (03) :370-371
[3]   A comparison of techniques for placement of double-lumen endobronchial tubes [J].
Boucek, CD ;
Landreneau, R ;
Freeman, JA ;
Strollo, D ;
Bircher, NG .
JOURNAL OF CLINICAL ANESTHESIA, 1998, 10 (07) :557-560
[4]  
BRODSKY JB, 1991, ANESTH ANALG, V73, P570
[5]   Predicting the depth of insertion of left-sided double-lumen endobronchial tubes [J].
Chow, MYH ;
Goh, MH ;
Ti, LK .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (04) :456-458
[6]  
COHEN JA, 1986, ANESTH ANALG, V65, P100
[7]   Can insertion length for a double-lumen endobronchial tube be predicted? [J].
Dyer, RA ;
Heijke, SAM ;
Russell, WJ ;
Bloch, MB ;
James, MFM .
ANAESTHESIA AND INTENSIVE CARE, 2000, 28 (06) :666-668
[8]   A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic [J].
Heir, Jagtar Singh ;
Guo, Shu-Lin ;
Purugganan, Ronaldo ;
Jackson, Tim A. ;
Sekhon, Anupamjeet Kaur ;
Mirza, Kazim ;
Lasala, Javier ;
Feng, Lei ;
Cata, Juan P. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) :267-274
[9]   Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia - A prospective study [J].
Klein, U ;
Karzai, W ;
Bloos, F ;
Wohlfarth, M ;
Gottschall, R ;
Fritz, H ;
Gugel, M ;
Seifert, A .
ANESTHESIOLOGY, 1998, 88 (02) :346-350
[10]   Comparison of VivaSight double-lumen tube with a conventional double-lumen tube in adult patients undergoing video-assisted thoracoscopic surgery [J].
Levy-Faber, D. ;
Malyanker, Y. ;
Nir, R. -R. ;
Best, L. A. ;
Barak, M. .
ANAESTHESIA, 2015, 70 (11) :1259-1263