Evaluation of the Abbott ARCHITECT Toxo IgM assay

被引:9
|
作者
Sickinger, Eva [2 ]
Braun, Hans-Bertram [2 ]
Praast, Gerald [2 ]
Stieler, Myriam [2 ]
Gundlach, Cordelia [2 ]
Birkenbach, Claudia [2 ]
Prostko, John [1 ]
Palafox, Mary Ann [1 ]
Frias, Edwin [1 ]
Hsu, Stephen [1 ]
Matias, Matthew [1 ]
Pucci, Dominick [1 ]
Hausmann, Michael [2 ]
Sagel, Ulrich [3 ]
Smith, Darwin [1 ]
机构
[1] Abbott Diagnost, Abbott Pk, IL 60064 USA
[2] Abbott GmbH & Co KG, D-65205 Wiesbaden, Germany
[3] Austrian Agcy Hlth & Food Safety AGES, Inst Med Microbiol & Hyg, A-1096 Vienna, Austria
关键词
Toxoplasmosis; Toxo IgM; Acute infection; TOXOPLASMA-GONDII INFECTION; IMMUNOGLOBULIN-M ANTIBODIES; AGGLUTINATION-TEST; PREGNANT-WOMEN; RISK-FACTORS; AVIDITY; DIAGNOSIS; SYSTEM;
D O I
10.1016/j.diagmicrobio.2009.03.016
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [1] Toxoplasmosis serodiagnosis:: evaluation of Access® Toxo IgM II assay compared to Axsym® Toxo IgM and Vidas® Toxo IgM assays
    Decoster, A
    Lambert, N
    Germaneau, C
    Masson, C
    ANNALES DE BIOLOGIE CLINIQUE, 2000, 58 (06) : 721 - 727
  • [2] Comparative evaluation of the ARCHITECT Toxo IgG, IgM, and IgG Avidity assays for anti-Toxoplasma antibodies detection in pregnant women sera
    Gay-Andrieu, Francoise
    Fricker-Hidalgo, Helene
    Sickinger, Eva
    Espern, Anne
    Brenier-Pinchart, Marie-Pierre
    Braun, Hans-Bertram
    Pelloux, Herve
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 65 (03) : 279 - 287
  • [3] Evaluation of the performance of the Abbott ARCHITECT HIV Ag/Ab Combo Assay
    Chavez, Pollyanna
    Wesolowski, Laura
    Patel, Pragna
    Delaney, Kevin
    Owen, S. Michele
    JOURNAL OF CLINICAL VIROLOGY, 2011, 52 : S51 - S55
  • [4] Assessment of the diagnostic performance of the IDS-iSYS tests for toxo IgG, toxo IgM and avidity
    Levigne, Pauline
    Peyron, Francois
    Wallon, Martine
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2016, 86 (02) : 148 - 152
  • [5] Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments
    Gaze, David C.
    Prante, Christian
    Dreier, Jens
    Knabbe, Cornelius
    Collet, Corinne
    Launay, Jean-Marie
    Franekova, Janka
    Jabor, Antonin
    Lennartz, Lieselotte
    Shih, Jessie
    del Rey, Jose Manuel
    Zaninotto, Martina
    Plebani, Mario
    Collinson, Paul O.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (06) : 919 - 926
  • [6] Performance of a Toxo IgM prototype assay for the diagnosis of maternal and congenital Toxoplasma infections
    Wallon, Martine
    Fricker-Hidalgo, Helene
    Chapey, Emmanuelle
    Bailet, Claire
    Dard, Celine
    Brenier-Pinchart, Marie-Pierre
    Pelloux, Herve
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (11) : 1959 - 1964
  • [7] Development of Fully Automated Determination of Marker-Specific Immunoglobulin G (IgG) Avidity Based on the Avidity Competition Assay Format: Application for Abbott Architect Cytomegalovirus and Toxo IgG Avidity Assays
    Curdt, Ingo
    Praast, Gerald
    Sickinger, Eva
    Schultess, Jan
    Herold, Iris
    Braun, Hans Bertram
    Bernhardt, Stephanie
    Maine, Gregory T.
    Smith, Darwin D.
    Hsu, Stephen
    Christ, Heike M.
    Pucci, Dominick
    Hausmann, Michael
    Herzogenrath, Joerg
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (03) : 603 - 613
  • [8] Performance characteristics of the new ARCHITECT Toxo IgG and Toxo IgG Avidity assays
    Sickinger, Eva
    Gay-Anddrieu, Francoise
    Jonas, Gesa
    Schultess, Jan
    Stieler, Myriam
    Smith, Darwin
    Hausmann, Michael
    Stricker, Rene
    Stricker, Reto
    Dhein, Jens
    Braun, Hans-Bertram
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2008, 62 (03) : 235 - 244
  • [9] Evaluation of the New Elecsys Toxo IgG Avidity Assay for Toxoplasmosis and New Insights into the Interpretation of Avidity Results
    Murat, Jean-Benjamin
    L'Ollivier, Coralie
    Hidalgo, Helene Fricker
    Franck, Jacqueline
    Pelloux, Herve
    Piarroux, Renaud
    CLINICAL AND VACCINE IMMUNOLOGY, 2012, 19 (11) : 1838 - 1843
  • [10] Evaluation of the Roche Elecsys Toxo IgG and IgM electrochemiluminescence immunoassay for the detection of gestational Toxoplasma infection
    Prusa, Andrea-Romana
    Hayde, Michael
    Unterasinger, Lukas
    Pollak, Arnold
    Herkner, Kurt R.
    Kasper, David C.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2010, 68 (04) : 352 - 357