Stability and Control of a Metal Oxide Gas Sensor in Simulated Wind

被引:4
作者
Dorsey, Kristen L. [1 ]
Pisano, Albert P. [2 ]
机构
[1] Smith Coll, Picker Engn Program, Northampton, MA 01063 USA
[2] Univ Calif San Diego, Dept Mech & Aerosp Engn, La Jolla, CA 92093 USA
关键词
Chemical sensors; air pollution; sensor phenomena and characterization; AIR-QUALITY; DIFFUSION; OXYGEN;
D O I
10.1109/JSEN.2015.2485939
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Semiconducting metal oxide gas chemical sensors show promise for applications in handheld and personalized air quality monitoring systems. One limitation of these sensors is their cross-response to outdoor factors, such as temperature and humidity fluctuations. Previously, airflow (e.g., wind) was known to modify sensor output, but the cause of this response was not greatly characterized. In this paper, we investigate the effect of airflow on the output of a commercial metal oxide sensor in dry and humid air. Upon exposure to a step in airflow, the output of these sensors increases by more than 6% over 1 h. We also control the temperature of the sensor's embedded heater resistor using an external proportional-integral controller. With this control, the sensor output after exposure to airflow increases by <1% over 1 h, demonstrating a stabilization scheme for air quality measurements that does not require additional temperature sensing equipment.
引用
收藏
页码:699 / 705
页数:7
相关论文
共 26 条
  • [1] Abelsohn A, 2011, CAN FAM PHYSICIAN, V57, P881
  • [2] Ozone flexible sensors fabricated by photolithography and laser ablation processes based on ZnO nanoparticles
    Acuautla, M.
    Bernardini, S.
    Gallais, L.
    Fiorido, T.
    Patout, L.
    Bendahan, M.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 : 602 - 611
  • [3] Amann M, 2008, 93 WHO
  • [4] [Anonymous], 2008, A1AMICS5521 VERS 2
  • [5] CMOS monolithic metal-oxide gas sensor microsystems
    Barrettino, D
    Graf, M
    Taschini, S
    Hafizovic, S
    Hagleitner, C
    Hierlemann, A
    [J]. IEEE SENSORS JOURNAL, 2006, 6 (02) : 276 - 286
  • [6] Bârsan N, 2003, J PHYS-CONDENS MAT, V15, pR813, DOI 10.1088/0953-8984/15/20/201
  • [7] Highly sensitive ZnO nanowire CO sensors with the adsorption of Au nanoparticles
    Chang, Shoou-Jinn
    Hsueh, Ting-Jen
    Chen, I-Cherng
    Huang, Bohr-Ran
    [J]. NANOTECHNOLOGY, 2008, 19 (17)
  • [8] Improving estimates of air pollution exposure through ubiquitous sensing technologies
    de Nazelle, Audrey
    Seto, Edmund
    Donaire-Gonzalez, David
    Mendez, Michelle
    Matamala, Jaume
    Nieuwenhuijsen, Mark J.
    Jerrett, Michael
    [J]. ENVIRONMENTAL POLLUTION, 2013, 176 : 92 - 99
  • [9] Devarakonda S., 2013, P 2 ACM SIGKDD INT W, P1, DOI DOI 10.1145/2505821.2505834
  • [10] EGASHIRA M, 1981, J PHYS CHEM-US, V85, P4125, DOI 10.1021/j150626a034