Acoustic Characterization and Enhanced Ultrasound Imaging of Long-Circulating Lipid-Coated Microbubbles

被引:21
|
作者
Li, Hongbo [1 ]
Yang, Yanye [1 ]
Zhang, Meimei [1 ,2 ]
Yin, Liping [2 ]
Tu, Juan [1 ]
Guo, Xiasheng [1 ]
Zhang, Dong [1 ,3 ]
机构
[1] Nanjing Univ, Dept Phys, Collaborat Innovat Ctr Adv Microstruct, Key Lab Modern Acoust, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Univ Chinese Med, Affiliated Hosp, Dept Ultrasonog, Nanjing, Jiangsu, Peoples R China
[3] Chinese Acad Sci, State Key Lab Acoust, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
cavitation; contrast agents (basic science); contrast agents (clinical); lipid-coated; long-circulation; microbubbles; ultrasound contrast agent; SMALL HEPATOCELLULAR-CARCINOMA; CONTRAST AGENT MICROBUBBLES; TRIGGERED DRUG-DELIVERY; FILLED MICROBUBBLES; ENCAPSULATED MICROBUBBLES; SIZE DISTRIBUTION; SHELL PROPERTIES; DIAGNOSIS; NANOPARTICLES; MICROCAPSULES;
D O I
10.1002/jum.14470
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-A long-circulating lipid-coated ultrasound (US) contrast agent was fabricated to achieve a longer wash-out time and gain more resistance against higher-mechanical index sonication. Systemic physical, acoustic, and in vivo imaging experiments were performed to better understand the underlying mechanism enabling the improvement of contrast agent performance by adjusting the physical and acoustic properties of contrast agent microbubbles. Methods-By simply altering the gas core, a kind of US contrast agent microbubble was synthesized with a similar lipid-coating shell as SonoVue microbubbles (Bracco SpA, Milan, Italy) to achieve a longer wash-out time and higher inertial cavitation threshold. To bridge the structure-performance relationship of the synthesized microbubbles, the imaging performance of the microbubbles was assessed in vivo with SonoVue as a control group. The size distribution and inertial cavitation threshold of the synthesized microbubbles were characterized, and the shell parameters of the microbubbles were determined by acoustic attenuation measurements. All of the measurements were compared with SonoVue microbubbles. Results-The synthesized microbubbles had a spherical shape, a smooth, consistent membrane, and a uniform distribution, with an average diameter of 1.484 m. According to the measured attenuation curve, the synthesized microbubbles resonated at around 2.8 MHz. Although the bubble's shell elasticity (0.20.09 N/m) was comparable with SonoVue, it had relatively greater viscosity and inertial cavitation because of the different gas core. Imaging studies showed that the synthesized microbubbles had a longer circulation time and a better chance of fighting against rapid collapse than SonoVue. Conclusions-Nano/micrometer long-circulating lipid-coated microbubbles could be fabricated by simply altering the core composition of SonoVue microbubbles with a higher-molecular weight gas. The smaller diameter and higher inertial cavitation threshold of the synthesized microbubbles might make it easier to access deep-seated organs and give prolonged imaging enhancement in the liver.
引用
收藏
页码:1243 / 1256
页数:14
相关论文
共 50 条
  • [1] Ultrasound characterization of lipid-coated microbubbles
    Rossi, Simona
    Waton, Gilles
    Krafft, Marie Pierre
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237
  • [2] Dynamics of lipid-coated microbubbles
    Borden, Mark
    Kwan, James
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [3] Contrast-enhanced ultrasound imaging using long-circulating cationic magnetic microbubbles in vitro and in vivo validations
    Liu, Yingying
    Lai, Xiaoshu
    Zhu, Yao
    Guo, Fengjuan
    Su, Lili
    Arkin, Gulzira
    He, Tianzhen
    Xu, Jinfeng
    Ran, Haitao
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 616
  • [4] Acoustic characterization of monodisperse lipid-coated microbubbles: Relationship between size and shell viscoelastic properties
    Parrales, Miguel A.
    Fernandez, Juan M.
    Perez-Saborid, Miguel
    Kopechek, Jonathan A.
    Porter, Tyrone M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 136 (03): : 1077 - 1084
  • [5] Therapeutic applications of lipid-coated microbubbles
    Unger, EC
    Porter, T
    Culp, W
    Labell, R
    Matsunaga, T
    Zutshi, R
    ADVANCED DRUG DELIVERY REVIEWS, 2004, 56 (09) : 1291 - 1314
  • [6] Acoustic characterization of monodisperse lipid-coated microbubbles: Relationship between size and shell viscoelastic properties
    Parrales, Miguel A. (mparrales@us.es), 1600, Acoustical Society of America (136):
  • [7] MODELLING LIPID-COATED MICROBUBBLES IN FOCUSED ULTRASOUND APPLICATIONS AT SUBRESONANCE FREQUENCIES
    Guemmer, Jonas
    Schenke, Soeren
    Denner, Fabian
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (10): : 2958 - 2979
  • [8] Lateral phase separation in lipid-coated microbubbles
    Borden, MA
    Martinez, GV
    Ricker, J
    Tsvetkova, N
    Longo, M
    Gillies, RJ
    Dayton, PA
    Ferrara, KW
    LANGMUIR, 2006, 22 (09) : 4291 - 4297
  • [9] PHYSICAL CHARACTERISTICS OF ULTRASTABLE LIPID-COATED MICROBUBBLES
    DARRIGO, JS
    IMAE, T
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1992, 149 (02) : 592 - 595
  • [10] Shell viscosity estimation of lipid-coated microbubbles
    Cattaneo, Marco
    Supponen, Outi
    SOFT MATTER, 2023, 19 (31) : 5925 - 5941