Safety and efficacy of argon plasma coagulation trimming of malpositioned and migrated biliary metal stents: A controlled study in the porcine model

被引:19
作者
Chen, Yang K.
Jakribettuu, Vaman
Springer, Erik W.
Shah, Raj J.
Penberthy, Jeanine
Nash, S. Russell
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Pathol, Denver, CO 80262 USA
[2] Univ Colorado, Hlth Sci Ctr, Div Gastroenterol & Hepatol, Denver, CO USA
关键词
D O I
10.1111/j.1572-0241.2006.00744.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND: Argon plasma coagulation (APC) has been used to trim uncovered Elgiloy((R)) stents, but the extent of thermal damage and bile duct injury is not known. The goal of this study was to evaluate the safety and efficacy of APC for this application. METHODS: Eight Elgiloy((R)) (covered and uncovered) and four nitinol stents were deployed in the bile duct at ERCP in 12 anesthetized pigs. In nine pigs, the excess distal ends were trimmed in vivo using short bursts of APC. Three pigs served as controls. Bile ducts and stent specimens were then harvested for gross and histological examinations by a single-blinded pathologist. RESULTS: APC effectively trimmed all the stents. Seven APC-treated bile ducts and three controls showed epithelial distortion consistent with pressure injury from stent expansion. Two APC-treated bile ducts showed mild thermal injury. The damage was superficial, extending to a maximum depth of 0.1 mm with rare foci involving subepithelial connective tissue. CONCLUSION: APC at indicated settings effectively cuts covered and uncovered Elgiloy((R)) as well as nitinol stents, but can cause biliary epithelial injury secondary to conduction of heat and electrical energy. Proper technique and settings should be followed and short bursts of energy judiciously applied in order to minimize this danger.
引用
收藏
页码:2025 / 2030
页数:6
相关论文
共 18 条
  • [11] Endoscopic removal of a biliary wallstent with a suture-cutting device in a patient with primary pancreatic lymphoma
    Levy, MJ
    Wiersema, J
    [J]. ENDOSCOPY, 2002, 34 (10) : 835 - 837
  • [12] Libby ED, 1996, AM J GASTROENTEROL, V91, P1301
  • [13] Open-biopsy-forceps technique for endoscopic removal of distally migrated and impacted biliary metallic stents
    Matsushita, M
    Takakuwa, H
    Nishio, A
    Kido, M
    Shimeno, N
    [J]. GASTROINTESTINAL ENDOSCOPY, 2003, 58 (06) : 924 - 927
  • [14] LASER ENDOSURGERY ON BILIARY WIRE MESH STENTS
    SCHWARTZ, R
    ZERA, R
    CASS, O
    [J]. GASTROINTESTINAL ENDOSCOPY, 1993, 39 (05) : 735 - 736
  • [15] Endoscopic removal of a metallic biliary stent: case report
    Trentino, P
    Falasco, G
    d'Orta, C
    Coda, S
    [J]. GASTROINTESTINAL ENDOSCOPY, 2004, 59 (02) : 321 - 323
  • [16] DELAYED SPONTANEOUS MIGRATION OF GIANTURCO-ROSCH METALLIC STENT FROM THE BILIARY TREE
    TSAI, CC
    MO, LR
    LIN, RC
    KUO, JY
    CHANG, KK
    YUEH, SK
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1995, 20 (03) : 221 - 223
  • [17] Endoscopic argon plasma trimming of biliary and gastrointestinal metallic stents
    Vanbiervliet, G
    Piche, T
    Caroli-Bosc, FX
    Dumas, R
    Peten, EP
    Huet, PM
    Tran, A
    Demarquay, JF
    [J]. ENDOSCOPY, 2005, 37 (05) : 434 - 438
  • [18] Treatment of metallic biliary stent-induced duodenal ulceration using endoscopic laser therapy
    Yarze, JC
    Poulos, AM
    Fritz, HP
    Herlihy, KJ
    [J]. DIGESTIVE DISEASES AND SCIENCES, 1997, 42 (01) : 6 - 9