Influence of 50 Hz frequency sinusoidal magnetic field on the blood-brain barrier permeability of diabetic rats

被引:15
作者
Oztas, B [1 ]
Kalkan, T [1 ]
Tuncel, H [1 ]
机构
[1] Istanbul Univ, Istanbul Fac Med, Dept Physiol, TR-34390 Istanbul, Turkey
关键词
blood-brain barrier; magnetic field; diabetic rats; ELF; Evans-blue albumin; normoglycemic;
D O I
10.1002/bem.20030
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The combined effects of diabetes and a 50 Hz, 5 mT RMS flux density sinusoidal magnetic field for 8 h a day, for 21 consecutive days on the permeation of Evans-blue dye through the blood-brain barrier were studied in male Wistar albino rats. Our results suggest that magnetic field has no effect on the blood-brain barrier permeability in normoglycemic animals, but that diabetic rats are vulnerable to magnetic fields. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:400 / 402
页数:3
相关论文
共 15 条
[1]  
Finnie JW, 2001, PATHOLOGY, V33, P338
[2]   The EMF to BBB connection - Studying the effects of electromagnetic energy on the blood-brain barrier [J].
Lapin, GD .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (04) :57-60
[3]   Central nervous system complications of diabetes mellitus - A perspective from the blood-brain barrier [J].
Mooradian, AD .
BRAIN RESEARCH REVIEWS, 1997, 23 (03) :210-218
[4]   INFLUENCE OF ACUTE ARTERIAL-HYPERTENSION ON BLOOD-BRAIN-BARRIER PERMEABILITY IN STREPTOZOCIN-INDUCED DIABETIC RATS [J].
OZTAS, B ;
KUCUK, M .
NEUROSCIENCE LETTERS, 1995, 188 (01) :53-56
[5]   INCREASED PERMEABILITY OF THE BLOOD-BRAIN-BARRIER INDUCED BY MAGNETIC AND ELECTROMAGNETIC-FIELDS [J].
PERSSON, BRR ;
SALFORD, LG ;
BRUN, A ;
EBERHARDT, JL ;
MALMGREN, L .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES-SERIES, 1992, 649 :356-358
[6]   BLOOD-BRAIN-BARRIER PERMEABILITY IN RATS IS ALTERED BY EXPOSURE TO MAGNETIC-FIELDS ASSOCIATED WITH MAGNETIC-RESONANCE-IMAGING AT 1.5-T [J].
PRATO, FS ;
WILLS, JM ;
ROGER, J ;
FRAPPIER, H ;
DROST, DJ ;
LEE, TY ;
SHIVERS, RR ;
ZABEL, P .
MICROSCOPY RESEARCH AND TECHNIQUE, 1994, 27 (06) :528-534
[7]  
Repacholi MH, 1998, BIOELECTROMAGNETICS, V19, P1, DOI 10.1002/(SICI)1521-186X(1998)19:1<1::AID-BEM1>3.0.CO
[8]  
2-5
[9]   PERMEABILITY OF THE BLOOD-BRAIN-BARRIER INDUCED BY 915 MHZ ELECTROMAGNETIC-RADIATION, CONTINUOUS-WAVE AND MODULATED AT 8, 16, 50, AND 200 HZ [J].
SALFORD, LG ;
BRUN, A ;
STURESSON, K ;
EBERHARDT, JL ;
PERSSON, BRR .
MICROSCOPY RESEARCH AND TECHNIQUE, 1994, 27 (06) :535-542
[10]  
Schirmacher A, 2000, BIOELECTROMAGNETICS, V21, P338, DOI 10.1002/1521-186X(200007)21:5<338::AID-BEM2>3.0.CO