Long-term structural failure of coaxial polyurethane implantable cardioverter defibrillator leads

被引:37
作者
Hauser, RG
Cannom, D
Hayes, DL
Parsonnet, V
Hayes, J
Ratliff, N
Tyers, GFO
Epstein, AE
Vlay, SC
Furman, S
Gross, J
机构
[1] Minneapolis Heart Inst Fdn, Minneapolis, MN USA
[2] Good Samaritan Hosp, Los Angeles, CA USA
[3] Mayo Clin, Rochester, MN USA
[4] Newark Beth Israel, Newark, NJ USA
[5] Marshfield Clin Fdn Med Res & Educ, Marshfield, WI USA
[6] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[7] Univ Alabama Birmingham, Birmingham, AL USA
[8] Univ Hosp Stony Brook, Stony Brook, NY USA
[9] Montefiore Med Ctr, Bronx, NY 10467 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2002年 / 25卷 / 06期
关键词
implantable cardioverter defibrillator; leads; complications; registry;
D O I
10.1046/j.1460-9592.2002.t01-1-00879.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transvene models 693616966, a coaxial polyurethane ICD lead, may be prone to structural failure. These models comprise 54% of ICD lead failures in the authors' Multicenter Registry database. Because ICD leads perform a vital function, the clinical features, causes, and probability of Transvene 693616966 lead failure were determined. The Registry and United States Food and Drug Administration databases were queried for the clinical features and structural causes of the Transvene 693616966 lead failure, and a five-center substudy estimated the survival probability for 521 Transvene 6936/6966 implants. The mean time to failure was 4.8 +/- 2.1 years, and the estimated survival at 60 and 84 months after implant were 92% and 84%, respectively. Oversensing was the most common sign of failure (76%), and 24 patients experienced inappropriate shocks. The manufacturer's reports indicated that high voltage coil fracture and 80A polyurethane defects were the predominant causes of lead failure. Transvene models 6936 and 6966 coaxial polyurethane ICD leads are prone to failure over time. Patients who have these leads should be evaluated frequently, Additional studies are needed to identify safe management strategies.
引用
收藏
页码:879 / 882
页数:4
相关论文
共 50 条
  • [31] Long-term prognosis and emergency management for patients with an implantable cardioverter defibrillator: the EMERGE-ICD study
    Suero, Coral
    Martin, Alfonso
    Coll-Vinent, Blanca
    Gonzalez-Torrecilla, Esteban
    Ormaetxe, Jose
    Alvarez, Miguel
    del Arco, Carmen
    Cancio, Manuel
    Varona, Mercedes
    Sanchez, Susana
    Sanchez, Juan
    Fernandez-Lozano, Ignacio
    Arribas, Fernando
    Martin-Mendez, Maria
    Peinado, Rafael
    EMERGENCIAS, 2023, 35 (03): : 185 - 195
  • [32] Long-Term Survival in Patients with or without Implantable Cardioverter Defibrillator after Transcatheter Aortic Valve Implantation
    Fischer-Rasokat, Ulrich
    Renker, Matthias
    Liebetrau, Christoph
    Weferling, Maren
    Rolf, Andreas
    Hain, Andreas
    Sperzel, Johannes
    Choi, Yeong-Hoon
    Hamm, Christian W.
    Kim, Won-Keun
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [33] Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients
    Fauchier, L
    Sadoul, N
    Kouakam, C
    Briand, F
    Chauvin, M
    Babuty, D
    Clementy, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 : S255 - S259
  • [34] Long-term implications of cumulative right ventricular pacing among patients with an implantable cardioverter-defibrillator
    Barsheshet, Alon
    Moss, Arthur J.
    McNitt, Scott
    Jons, Christian
    Glikson, Michael
    Klein, Helmut U.
    Huang, David T.
    Steinberg, Jonathan S.
    Brown, Mary W.
    Zareba, Wojciech
    Goldenberg, Ilan
    HEART RHYTHM, 2011, 8 (02) : 212 - 218
  • [35] Long-Term Follow-Up of Patients with Chronic Chagas Disease and Implantable Cardioverter-Defibrillator
    Moreira Pereira, Francisca Tatiana
    Rocha, Eduardo Arrais
    Martins Monteiro, Marcelo De Paula
    Rocha Neto, Almino Cavalcante
    Daher, Elisabeth De Francesco
    Martins Rodrigues Sobrinho, Carlos Roberto
    Pires Neto, Roberto Da Justa
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (06): : 751 - 756
  • [36] The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator
    Yao, Guiqing
    Freemantle, Nick
    Calvert, Melanie J.
    Bryan, Stirling
    Daubert, Jean-Claude
    Cleland, John G. F.
    EUROPEAN HEART JOURNAL, 2007, 28 (01) : 42 - 51
  • [37] Long-term outcome of implantable cardioverter-defibrillator implantation in secondary prevention of sudden cardiac death
    Boule, Stephane
    Semichon, Marc
    Guedon-Moreau, Laurence
    Drumez, Elodie
    Kouakam, Claude
    Marquie, Christelle
    Brigadeau, Francois
    Kacet, Salem
    Potelle, Charlotte
    Escande, William
    Souissi, Zouheir
    Lacroix, Dominique
    Duhamel, Alain
    Klug, Didier
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2016, 109 (10) : 517 - 526
  • [38] Long-term performance of single-connector (DF4) implantable defibrillator leads
    Ibrahim, Rand
    Al-Gibbawi, Mounir
    Mekary, Wissam
    Bhatia, Neal Kumar
    Kiani, Soroosh
    Westerman, Stacy B.
    Shah, Anand D.
    Lloyd, Michael S.
    Leal, Miguel
    De Lurgio, David B.
    Patel, Anshul M.
    Tompkins, Christine
    Leon, Angel R.
    Merchant, Faisal M.
    El-Chami, Mikhael F.
    EUROPACE, 2023, 25 (12):
  • [39] Long-term adherence to a wearable for continuous behavioural activity measuring in the SafeHeart implantable cardioverter defibrillator population
    Frodi, Diana My
    Kolk, Maarten Z. H.
    Langford, Joss
    Knops, Reinoud
    Tan, Hanno L.
    Andersen, Tariq Osman
    Jacobsen, Peter Karl
    Risum, Niels
    Svendsen, Jesper Hastrup
    Tjong, Fleur V. Y.
    Diederichsen, Soren Zoega
    EUROPEAN HEART JOURNAL - DIGITAL HEALTH, 2024, 5 (05): : 622 - 632
  • [40] Role of implantable cardioverter defibrillator therapy in patients with acquired long QT syndrome: A long-term follow-up
    Moennig, Gerold
    Koebe, Julia
    Loeher, Andreas
    Wasmer, Kristina
    Milberg, Peter
    Zellerhoff, Stephan
    Pott, Christian
    Zumhagen, Sven
    Radu, Razvan
    Scheld, Hans H.
    Haverkamp, Wilhelm
    Schulze-Bahr, Eric
    Eckardt, Lars
    EUROPACE, 2012, 14 (03): : 396 - 401