Design Methodology of a Printed WPT System for HF-Band Mid-Range Applications Considering Human Safety Regulations

被引:22
作者
Koohestani, Mohsen [1 ]
Zhadobov, Maxim [1 ]
Ettorre, Mauro [1 ]
机构
[1] Univ Rennes 1, Inst Elect & Telecommun Rennes, F-35042 Rennes, France
关键词
Dosimetry; exposure assessment; mid-range applications; printed technology; wireless power transfer (WPT); WIRELESS POWER TRANSFER; TRANSMISSION; RESONATORS; COIL;
D O I
10.1109/TMTT.2016.2609931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A methodology for the design of printed magnetically coupled resonant wireless power-transfer (WPT) systems is proposed. The design methodology aims at a well-matched system with a maximized power-transfer efficiency for mid-range applications. The system consists of two identical resonant coils driven by high-quality factor loops. The proposed design criteria allows obtaining maximum achievable transfer efficiency and impedance matching at any defined distance without any external matching circuits connected to the driven loops. For validation purposes, a printed WPT system at 10 MHz is fabricated targeting 1m distance between the transmitting and receiving sides. Its performances in terms of reflection and transmission coefficients, as well as in terms of generated electric and magnetic fields, have been characterized numerically and experimentally. The impact of human body presence on the system has also been investigated observing the splitting in two frequencies of the common resonant frequency of the coils. A dosimetric study has been conducted using a detailed high-resolution anatomical human body model and considering E-99, J(1) cm(2), and specific absorption rate (SAR) (local and whole body averaged SAR) as exposure metrics. It has been observed that peak exposure levels appear in different tissues depending on the body location. Compliance with the international commission on nonionizing radiation protection (ICNIRP) reference level as well as basic restrictions has been studied followed by computing the maximum allowable input power. It has been found that, with the body located 1 m away from the transmitting coil, the maximum allowable input power satisfying E-99 is in the order of MW, whereas it reduces to tens of kilowatt when considering SAR and J(1) cm(2). The latter has been noticed to be the most restrictive dosimetric quantity.
引用
收藏
页码:270 / 279
页数:10
相关论文
共 30 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]   Analysis of the Double-Layer Printed Spiral Coil for Wireless Power Transfer [J].
Chen, Kainan ;
Zhao, Zhengming .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2013, 1 (02) :114-121
[3]   Evaluation of Wireless Resonant Power Transfer Systems With Human Electromagnetic Exposure Limits [J].
Christ, Andreas ;
Douglas, Mark G. ;
Roman, John M. ;
Cooper, Emily B. ;
Sample, Alanson P. ;
Waters, Benjamin H. ;
Smith, Joshua R. ;
Kuster, Niels .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2013, 55 (02) :265-274
[4]   The Virtual Family-development of surface-based anatomical models of two adults and two children for dosimetric simulations [J].
Christ, Andreas ;
Kainz, Wolfgang ;
Hahn, Eckhart G. ;
Honegger, Katharina ;
Zefferer, Marcel ;
Neufeld, Esra ;
Rascher, Wolfgang ;
Janka, Rolf ;
Bautz, Werner ;
Chen, Ji ;
Kiefer, Berthold ;
Schmitt, Peter ;
Hollenbach, Hans-Peter ;
Shen, Jianxiang ;
Oberle, Michael ;
Szczerba, Dominik ;
Kam, Anthony ;
Guag, Joshua W. ;
Kuster, Niels .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (02) :N23-N38
[5]   A Transponder-Based, Nonradiative Wireless Power Transfer [J].
Ettorre, Mauro ;
Grbic, Anthony .
IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2012, 11 :1150-1153
[6]   Wireless Power Transfer in Loosely Coupled Links: Coil Misalignment Model [J].
Fotopoulou, Kyriaki ;
Flynn, Brian W. .
IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (02) :416-430
[7]   Efficiency and Optimal Loads Analysis for Multiple-Receiver Wireless Power Transfer Systems [J].
Fu, Minfan ;
Zhang, Tong ;
Ma, Chengbin ;
Zhu, Xinen .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (03) :801-812
[8]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[9]   Comprehensive Analysis and Measurement of Frequency-Tuned and Impedance-Tuned Wireless Non-Radiative Power-Transfer Systems [J].
Heebl, Jason D. ;
Thomas, Erin M. ;
Penno, Robert P. ;
Grbic, Anthony .
IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2014, 56 (05) :131-148
[10]   A Critical Review of Recent Progress in Mid-Range Wireless Power Transfer [J].
Hui, S. Y. R. ;
Zhong, Wenxing ;
Lee, C. K. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (09) :4500-4511