Numerical analysis of overhead transmission line galloping considering wind turbulence

被引:0
|
作者
Ohkuma, T [1 ]
Kagami, J
Nakauchi, H
Kikuchi, T
Takeda, K
Marukawa, H
机构
[1] Kanagawa Univ, Yokohama, Kanagawa, Japan
[2] Tokyo Elect Power Co Ltd, Tokyo, Japan
[3] Asahi Elect Works Ltd, Tokyo, Japan
关键词
wind turbulence; galloping simulation; moving mean; transmission line;
D O I
10.1002/(SICI)1520-6416(200003)131:3<19::AID-EEJ3>3.0.CO;2-S
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study aims at clarifying the factors that cause transmission line galloping and the conditions influencing it, and at determining response evaluation indices of gallopings in turbulent flows. This is done using a three-dimensional analytical method considering a large deformation. The analysis is based on four-bundle transmission lines. Obtained results are as follows: 1) The occurrence of galloping in the smooth flow is limited by the combination of the following parameters: the initial angle of wind attack, the initial icing angle, and the wind speed. The galloping predominates mainly with one or two of the lowest in-plane, out-of-plane, and torsional modes for the free vibration under the conditions that the transmission line is subject to dead load as well as static wind force. However, the galloping always occurs with torsional vibration. 2) The shape of the Lissajous figure for displacement depends on the initial angle of wind attack and the initial icing angle, as well as wind speed. The main shapes are vertically elliptic, horizontally elliptic, and a configuration having the shape of a horizontally rotated figure of eight. 3) The predominant frequency components of gallopings in turbulent flows are amplified and controlled by the turbulence intensity. Vibration frequency components unrelated to galloping increase linearly with rise in turbulence intensity. 4) There is a time lag of 30 a between galloping vibration and the fluctuating wind speed. The relationships between mean wind speeds and both trend components and standard deviations of galloping in turbulent flows closely correspond to those relationships during the smooth flow, and they can be obtained using the average time of 10 times the shortest vibration period of the transmission line. That is, the response values of transmission lines in the smooth flow can be utilized to estimate gallopings in turbulent flows. To estimate the maximum amplitude of a galloping, a peak factor of approximately 2.5 can be used. (C) 2000 Scripta Technica.
引用
收藏
页码:19 / 33
页数:15
相关论文
共 50 条
  • [1] Study on the galloping of overhead transmission line
    Wuhan Shuili Dianli Daxue Xuebao, 5 (506-509):
  • [2] Overhead Transmission Line Vibration and Galloping
    Wang, Jeff
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 120 - 123
  • [3] Galloping of overhead transmission lines in gusty wind
    Ohkuma, T
    Marukawa, H
    WIND AND STRUCTURES, 2000, 3 (04) : 243 - 253
  • [4] Theoretical Analysis and Countermeasures on Iced Galloping of Overhead Transmission Line
    Shang, Q. H.
    Cheng, Y. F.
    Liu, B.
    Zhao, B.
    Yang, J. L.
    Zhang, L. C.
    Zhan, X. P.
    Li, P.
    2016 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY, ENVIRONMENT AND INFORMATION ENGINEERING (SEEIE 2016), 2016, : 542 - 547
  • [5] Galloping of overhead transmission lines in gusty wind
    Ohkuma, T
    Marukawa, H
    STRUCTURAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 1999, : 1725 - 1730
  • [6] Numerical analysis of the iced transmission line galloping
    Qin Li
    Xu Tianyuan
    MACHINE DESIGN AND MANUFACTURING ENGINEERING III, 2014, : 894 - 900
  • [7] Comprehensive analysis for conductor galloping of overhead transmission line and preventive measures
    Huang Jingya Central China Electric Power Testing and Research Institute
    Electricity, 1992, (04) : 45 - 50
  • [8] Galloping behavior of insulated overhead transmission line based on aerodynamic analysis
    Liang, Hucheng
    Zhang, Zekai
    Kong, Xiaoxiao
    Yang, Daiyong
    Lie, Jianping
    Du, Boxue
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [9] Numerical Noise Analysis for Insulator of Overhead Transmission Line
    Zhang, Yulin
    Chen, Yuwen
    Huang, Yu
    ADVANCES IN MATERIALS, MACHINERY, ELECTRONICS II, 2018, 1955
  • [10] On galloping of bundled conductors in an overhead transmission line with large torsional motion
    He, Z.