Single-scan z-shim method for reducing susceptibility artifacts in gradient echo myelin water imaging

被引:11
作者
Lee, Doohee [1 ]
Lee, Jingu [1 ]
Lee, Jongho [1 ]
Nam, Yoonho [2 ]
机构
[1] Seoul Natl Univ, Dept Elect & Comp Engn, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Dept Radiol, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
field inhomogeneity; gradient echo; magnetic susceptibility artifact; myelin water imaging; z-shim; MACROSCOPIC FIELD INHOMOGENEITY; EXPONENTIAL EXCITATION PULSES; BACKGROUND GRADIENTS; WHITE-MATTER; MULTIPLE-SCLEROSIS; T-2-ASTERISK DECAY; COMPENSATION; IMAGES; BRAIN; MRI;
D O I
10.1002/mrm.27127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMyelin water imaging (MWI) reportedly corresponds closely to the myelin content in the brain. An MWI technique based on multi-echo gradient echo (mGRE) has recently been proposed as an alternative to the conventional spin-echo-based MWI. However, the mGRE signal is vulnerable to macroscopic field inhomogeneity, which makes MWI unreliable. In the present study, a z-shim-based single-scan correction method is proposed to overcome this limitation. MethodsZ-shim gradients in the slice-selection direction were added to an mGRE sequence after an echo time of 12 ms. A 3-pool model corresponding to the proposed sequence was suggested for fitting the acquired signal. The method was evaluated through a comparison with methods without a correction and with post-processing only from non-z-shimmed data. To do this, numerical simulations and in vivo experiments were conducted. ResultsThe simulation and in vivo experiment results indicated that post-processing alone was not sufficient to offset the macroscopic field inhomogeneity, particularly in inferior regions of the brain. On the other hand, the proposed method compensated the field inhomogeneity in most brain areas. The estimated in vivo myelin water fraction values were in good agreement with literature values obtained by previously proposed field inhomogeneity correction method. ConclusionThe proposed method showed reliable myelin water fraction in most regions of the brain in vivo, including those with severe field inhomogeneity.
引用
收藏
页码:1101 / 1109
页数:9
相关论文
共 37 条
[1]   Field inhomogeneity correction for gradient echo myelin water fraction imaging [J].
Alonso-Ortiz, Eva ;
Levesque, Ives R. ;
Paquin, Raphael ;
Pike, G. Bruce .
MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) :49-57
[2]   Rapid Single-Scan T2*-Mapping Using Exponential Excitation Pulses and Image-Based Correction for Linear Background Gradients [J].
Baudrexel, Simon ;
Volz, Steffen ;
Preibisch, Christine ;
Klein, Johannes C. ;
Steinmetz, Helmuth ;
Hilker, Ruediger ;
Deichmann, Ralf .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) :263-268
[3]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[4]   Fast multislice mapping of the myelin water fraction using multicompartment analysis of T2* decay at 3T:: A preliminary postmortem study [J].
Du, Yiping P. ;
Chu, Renxin ;
Hwang, Dosik ;
Brown, Mark S. ;
Kleinschmidt-DeMasters, Bette K. ;
Singel, Debra ;
Simon, Jack H. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :865-870
[5]   Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation [J].
Du, Yiping P. ;
Dalwani, Manish ;
Wylie, Korey ;
Claus, Eric ;
Tregellas, Jason R. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) :396-404
[6]  
Fernández-Seara MA, 2000, MAGNET RESON MED, V44, P358, DOI 10.1002/1522-2594(200009)44:3<358::AID-MRM3>3.0.CO
[7]  
2-I
[8]   Single, slice-specific z-shim gradient pulses improve T2*-weighted imaging of the spinal cord [J].
Finsterbusch, Juergen ;
Eippert, Falk ;
Buechel, Christian .
NEUROIMAGE, 2012, 59 (03) :2307-2315
[9]   DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480
[10]  
Glover GH, 1999, MAGNET RESON MED, V42, P290, DOI 10.1002/(SICI)1522-2594(199908)42:2<290::AID-MRM11>3.0.CO