This study presents the production and full-scale testing of specific synthetic fiber-reinforced concrete pipes in a dry cast environment. Production and testing were conducted to identify the structural behavior of concrete pipes with synthetic fibers for the first time in the United States. Three production sites were selected to utilize different pipe manufacturing equipment. Each plant's mix design was kept to be the same as those used in the production of the conventional reinforced concrete pipes (RCP), except for replacing the steel cage with synthetic fibers and adjusting the amount of water in the composite mix of concrete and fibers. Synthetic fiber-reinforced concrete pipes (SY-FRCP) were tested based on industry standard specifications for strength requirements for pipe diameters ranging from 375 mm to 600 mm (15 in. to 36 in.). Full-scale structural strength and stiffness tests were conducted based on industry standard test methods, three-edge bearing tests, for obtaining the load deformation characteristics of SY-FRCP. Control test pipes were also produced and tested for comparison purposes by using the conventional industry standard specifications for reinforced concrete pipes with steel cage. The load deformation plots along with the crack pattern formation for both SY-FRCP and RCP were compared. The results of this study indicated the BASF MasterFiber MAC Matric synthetic fibers could be used as an alternative reinforcement of concrete pipes. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Performance of Steel Fiber-Reinforced Concrete Pipes
    Abolmaali, A.
    Mikhaylova, A.
    Wilson, A.
    Lundy, J.
    TRANSPORTATION RESEARCH RECORD, 2012, (2313) : 168 - 177
  • [2] SYNTHETIC FIBER-REINFORCED CONCRETE
    ZHENG, ZH
    FELDMAN, D
    PROGRESS IN POLYMER SCIENCE, 1995, 20 (02) : 185 - 210
  • [3] Experimental Investigation of Thin-Wall Synthetic Fiber-Reinforced Concrete Pipes
    Al Rikabi, Fouad T.
    Sargand, Shad M.
    Kurdziel, John
    Hussein, Husam H.
    ACI STRUCTURAL JOURNAL, 2018, 115 (06) : 1671 - 1681
  • [4] Chemical Resistance of Synthetic Fiber-Reinforced Concrete Pipes in Highly Corrosive Environments
    Mandavi, Maziar
    Abolmaali, Ali
    Tehrani, Amin
    PIPELINES 2024: PLANNING AND DESIGN, 2024, : 615 - 626
  • [5] Design Proposal for Synthetic Fiber-Reinforced Concrete Pipes Using Finite Element Analysis
    Al Rikabi, Fouad T.
    Sargand, Shad M.
    Hussein, Husam H.
    JOURNAL OF TESTING AND EVALUATION, 2020, 48 (02) : 871 - 895
  • [6] Performance of Thin-Wall Synthetic Fiber-Reinforced Concrete Pipes under Short and Long-Term Loading
    Al Rikabi, Fouad T.
    Sargand, Shad M.
    Kurdziel, John
    Khoury, Issam
    JOURNAL OF TESTING AND EVALUATION, 2020, 48 (05) : 3713 - 3733
  • [7] PERFORMANCE OF FIBER-REINFORCED CONCRETE PAVEMENT
    PACKARD, RG
    RAY, GK
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1984, 81 (05): : 516 - 516
  • [8] A new test method for evaluating the long-term performance of fiber-reinforced concrete pipes
    Al Rikabi, Fouad T.
    Sargand, Shad M.
    Khoury, Issam
    Kurdziel, John
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (07) : 1336 - 1349
  • [9] Fiber-Reinforced Concrete
    Bonakdar, Amir
    Mahoney, Michael A.
    Concrete International, 2021, 43 (11) : 27 - 30
  • [10] The Effects of Fiber Volume Ratio and Temperature on the Flexural Performance of Macro-Synthetic Fiber-Reinforced Concrete
    Saribiyik, Ali
    Degirmenci, Izzet
    Saribiyik, Mehmet
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2023, 47 (05) : 2865 - 2877