Using poly(3-aminophenylboronic acid) thin film with binding-induced ion flux blocking for amperometric detection of hemoglobin A1c

被引:49
作者
Wang, Jen-Yuan [1 ]
Chou, Tse-Chuan [2 ]
Chen, Lin-Chi [3 ]
Ho, Kuo-Chuan [1 ,4 ]
机构
[1] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
[2] Natl Cheng Kung Univ, Dept Chem Engn, Tainan 701, Taiwan
[3] Natl Taiwan Univ, Dept Bioind Mechatron Engn, Taipei 10617, Taiwan
[4] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
关键词
Diabetes; Electrochemical biosensors; Hemoglobin A1c (Hb(A1c)); Ion flux; Poly(3-aminophenylboronic acid); GLYCATED HEMOGLOBIN; BORONIC ACID; HBA(1C); ELECTRODES; GLUCOSE; SENSOR; POLYPYRROLE; POLYANILINE; BIOSENSOR; SURFACE;
D O I
10.1016/j.bios.2014.07.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study reports a novel enzyme-free, label-free amperometric method for direct detection of hemoglobin A1c (Hb(A1c)), a potent biomarker for diabetes diagnosis and prognosis. The method relies on an electrode modified with poly(3-aminophenylboronic acid) (PAPBA) nanoparticles (20-50 nm) and a sensing scheme named "binding-induced ion flux blocking." The PAPBA nanoparticles were characterized by FT-IR, XPS, TEM, and SEM. Being a polyaniline derivative, PAPBA showed an ion-dependent redox behavior, in which insertion or extraction of ions into or out of PABPA occurred for charge balance during the electron transfer process. The polymer allowed Hb(A1c), selectively bound to its surface via forming the cis-diol linkage between the boronic acid and sugar moieties. Voltammetric analyses showed that Hb(A1c) binding decreased the redox current of PAPBA; however, the binding did not alter the redox potentials and the apparent diffusivities of ions. This suggests that the redox current of PAPBA decreased due to an Hb(A1c) binding-induced ion flux blocking mechanism, which was then verified and characterized through an in situ electrochemical quartz crystal microbalance (EQCM) study. Assay with Hb(A1c) by differential pulse voltammeny (DPV) indicates that the peak current of a PAPBA electrode has a linear dependence on the logarithm of Hb(A1c), concentration ranging from 0.975 to 156 mu M. The Hb(A1c) assay also showed high selectivity against ascorbic acid, dopamine, uric acid, glucose and bovine serum albumin. This study has demonstrated a new method for developing an electrochemical Hb(A1c) biosensor and can be extended to other label-free, indicator-free protein biosensors based on a similar redox polymer electrode. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 44 条
  • [1] 4-mercaptophenylboronic acid SAMs on gold: Comparison with SAMs derived from thiophenol, 4-mercaptophenol, and 4-mereaptobenzoic acid
    Barriet, David
    Yam, Chi Ming
    Shmakova, Olga E.
    Jamison, Andrew C.
    Lee, T. Randall
    [J]. LANGMUIR, 2007, 23 (17) : 8866 - 8875
  • [2] Biological variability of glycated hemoglobin
    Braga, Federica
    Dolci, Alberto
    Mosca, Andrea
    Panteghini, Mauro
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (21-22) : 1606 - 1610
  • [3] Biomedical applications of boronic acid polymers
    Cambre, Jennifer N.
    Sumerlin, Brent S.
    [J]. POLYMER, 2011, 52 (21) : 4631 - 4643
  • [4] An amperometric hemoglobin A1c biosensor based on immobilization of fructosyl amino acid oxidase onto zinc oxide nanoparticles-polypyrrole film
    Chawla, Sheetal
    Pundir, Chandra Shekhar
    [J]. ANALYTICAL BIOCHEMISTRY, 2012, 430 (02) : 156 - 162
  • [5] An electrochemical biosensor for fructosyl valine for glycosylated hemoglobin detection based on core-shell magnetic bionanoparticles modified gold electrode
    Chawla, Sheetal
    Pundir, Chandra Shekhar
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) : 3438 - 3443
  • [6] Gold nanoparticles-coated magnetic microspheres as affinity matrix for detection of hemoglobin Al c in blood by microfluidic immunoassay
    Chen, Shao-Peng
    Yu, Xiao-Dong
    Xu, Jing-Juan
    Chen, Hong-Yuan
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (12) : 4779 - 4784
  • [7] A Nonenzymatic Amperometric Method for Fructosyl-Valine Sensing Using Ferroceneboronic Acid
    Chien, Hui-Ching
    Chou, Tse-Chuan
    [J]. ELECTROANALYSIS, 2011, 23 (02) : 402 - 408
  • [8] Detection of glycated hemoglobin (HbA1c) based on impedance measurement with parallel electrodes integrated into a microfluidic device
    Chuang, Ya-Chun
    Lan, Kung-Chieh
    Hsieh, Ku-Meng
    Jang, Ling-Sheng
    Chen, Ming-Kun
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1222 - 1230
  • [9] IMPROVED METHOD FOR ANALYSIS OF GLYCATED HEMOGLOBIN BY ION-EXCHANGE CHROMATOGRAPHY
    ECKERBOM, S
    BERGQVIST, Y
    JEPPSSON, JO
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1994, 31 : 355 - 360
  • [10] PROTEIN-BORONIC ACID CONJUGATES AND THEIR BINDING TO LOW-MOLECULAR-MASS CIS-DIOLS AND GLYCATED HEMOGLOBIN
    FRANTZEN, F
    GRIMSRUD, K
    HEGGLI, DE
    SUNDREHAGEN, E
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 670 (01): : 37 - 45