The Use of a Computerized Tomography-Based Software Program with a Flapless Surgical Technique in Implant Dentistry: A Case Report

被引:0
作者
Terzioglu, Hakan [1 ]
Akkaya, Murat [2 ]
Ozan, Oguz [3 ]
机构
[1] Ankara Univ, Dept Prosthodont, Fac Dent, TR-06500 Ankara, Turkey
[2] Ankara Univ, Dept Periodontol, Fac Dent, TR-06500 Ankara, Turkey
[3] Near East Univ, Dept Prosthodont, Fac Dent, TR-10 Mersin, Turkey
关键词
computerized tomography-based software; dental implant; flaples surgery; implant dentistry; PLACEMENT; ACCURACY; TEMPLATES; NAVIGATION; GUIDES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Successful implant treatment includes osseointegration, as well as prosthetically optimal positions of the implants for esthetics and function. The aim of this study is to evaluate a patient that was treated with an implant-supported fixed prosthesis with the help of computer-assisted three-dimensional planning. A 52-year-old edentulous man underwent computerized tomographic (CT) scanning, and the cross sections were reformatted. The cross sections were used to construct a surgical guide. Eight ITI Straumann dental implants were placed using a series of supramucosal surgical stents. Following a 5-month healing period, the stability of the implants was confirmed with the use of an Osstell device. Because satisfactory stability was observed, implant-supported fixed partial dentures, incorporating 12 units in all, were made. After 6 months, a second CT evaluation was carried Out and the positions of the implants were compared with the treatment planning data. The CT-based software program and surgical stents contributed to the Success of this case. INT J ORAL MAXILLOFAC IMPLANTS 2009:24:137-142
引用
收藏
页码:137 / 142
页数:6
相关论文
共 17 条
  • [1] Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography
    Besimo, CE
    Lambrecht, JT
    Guindy, JS
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) : 46 - 51
  • [2] Accuracy of image-guided implantology
    Brief, J
    Edinger, D
    Hassfeld, S
    Eggers, G
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 495 - 501
  • [3] Casap N, 2005, INT J ORAL MAX IMPL, V20, P92
  • [4] Chiu WK, 2006, INT J ORAL MAX IMPL, V21, P465
  • [5] Di Giacomo GAP, 2005, J PERIODONTOL, V76, P503
  • [6] Engelke W, 2005, INT J ORAL MAX IMPL, V20, P891
  • [7] Ikumi N, 2005, INT J ORAL MAX IMPL, V20, P253
  • [8] Predictability of a three-dimensional planning system for oral implant surgery
    Jacobs, R
    Adriansens, A
    Verstreken, K
    Suetens, P
    van Steenberghe, D
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (02) : 105 - 111
  • [9] Lal Kunal, 2006, J Prosthodont, V15, P51, DOI 10.1111/j.1532-849X.2006.00069.x
  • [10] Misch CE, 2015, Dental Implant Prosthetics