PVC membrane, coated-wire, and carbon-paste ion-selective electrodes for potentiometric determination of galantamine hydrobromide in physiological fluids

被引:36
作者
Abdel-Haleem, Fatehy M. [1 ]
Saad, Mohamed [1 ]
Barhoum, Ahmed [2 ]
Bechelany, Mikhael [3 ]
Rizk, Mahmoud S. [1 ]
机构
[1] Cairo Univ, Fac Sci, Chem Dept, Gamaa St, Giza 12613, Egypt
[2] Helwan Univ, Fac Sci, Chem Dept, Cairo 11795, Egypt
[3] Univ Montpellier, CNRS, ENSCM, Inst Europeen Membranes,UMR 5635, Pl Eugene Bataillon, F-34095 Montpellier 5, France
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2018年 / 89卷
关键词
Electrochemical biosensors; Ion-selective electrodes; Galantamine hydrobromide; PVC membrane electrode; Carbon-paste electrode; Coated-wire electrode; Graphene oxide; ELECTROCHEMICAL ANALYSIS; SENSORS; GRAPHENE; COEFFICIENTS; MERCURY(II);
D O I
10.1016/j.msec.2018.04.001
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
We report on highly-sensitive ion-selective electrodes (ISEs) for potentiometric determining of galantamine hydrobromide (GB) in physiological fluids. Galantamine hydrobromide (GB) was selected for this study due to its previous medical importance for treating Alzheimer's disease. Three different types of ISEs were investigated: PVC membrane electrode (PVCE), carbon-paste electrode (CPE), and coated-wire electrode (CWE). In the construction of these electrodes, galantaminium-reineckate (GR) ion-pair was used as a sensing species for GB in solutions. The modified carbon-paste electrode (MCPE) was prepared using graphene oxide (MCPE-GO) and sodium tetrakis (trifluoromethyl) phenyl borate (MCPE-SIFPB) as ion-exchanger. The potentiometric modified CPEs (MCPE-GO and MCPE-SIFPB) show an improved performance in term of Nernstian slope, selectivity, response time, and response stability compared to the unmodified CPE. The prepared electrodes PVCE, CWE, CPE, MCPE-GO and MCPE-STFPB show Nemstian slopes of 59.9, 59.5, 58.1, 58.3 and 57.0 mV/conc. decade, and detection limits of 5.0 x 10(-6), 6.3 x 10(-6), 8.0 x 10(-6), 6.0 x 10(-6) and 8.0 x 10(-6) mol L-1, respectively. The prepared ISEs also show high selectivity against cations (i.e. Na+, K+, NH4+, Ca2+, Al3+, Fe3+), amino acids (i.e. glycine, L-alanine alanine), and sugars (i.e. fructose, glucose, maltose, lactose). The prepared ISEs are applicable for determining GB in spiked serums, urines, and pharmaceutical preparations, using a standard addition and a direct potentiometric method. The fast response time (<10 s), long lifetime (1-5 weeks), reversibility and stability of the measured signals facilitate the application of these sensors for routine analysis of the real samples.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 36 条
[1]   Comparative Study of Carbon Paste, Screen Printed, and PVC Potentiometric Sensors Based on Copper-sulphamethazine Schiff Base Complex for Determination of Iodide - Experimental and Theoretical Approaches [J].
Abdel-Haleem, F. M. ;
Shehab, Ola R. .
ELECTROANALYSIS, 2016, 28 (04) :800-807
[2]   Potentiometric Determination of Ciprofloxacin in Physiological Fluids Using Carbon Paste and Nano-Composite Carbon Paste Electrodes [J].
Abdel-Haleem, Fatehy M. ;
Rizk, Mahmoud S. ;
Badr, Ibrahim H. A. .
ELECTROANALYSIS, 2017, 29 (04) :1172-1179
[3]   Potentiometric Anion Selectivity and Analytical Applications of Polymer Membrane Electrodes Based on Novel Mn(III)- and Mn(IV)-Salophen Complexes [J].
Abdel-Haleem, Fatehy M. ;
Badr, Ibrahim H. A. ;
Rizk, Mahmoud S. .
ELECTROANALYSIS, 2016, 28 (12) :2922-2929
[4]   Electroanalysis with Membrane Electrodes and Liquid-Liquid Interfaces [J].
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2016, 88 (01) :395-413
[5]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[6]   Ultrafast Graphene Oxide Humidity Sensors [J].
Borini, Stefano ;
White, Richard ;
Wei, Di ;
Astley, Michael ;
Haque, Samiul ;
Spigone, Elisabetta ;
Harris, Nadine ;
Kivioja, Jani ;
Ryhanen, Tapani .
ACS NANO, 2013, 7 (12) :11166-11173
[7]   Evaluation of sensor response characteristics [J].
Bunaciu, AA ;
Petrisor, C ;
Aboul-Enein, HY .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 1998, 26 (04) :353-362
[8]   Polymer membrane ion-selective electrodes as a convenient tool for lipases and esterases assays [J].
Cieplak, Maciej ;
Ostaszewski, Ryszard .
PREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY, 2017, 47 (07) :673-677
[9]   A ditopic calix[4]pyrrole amide derivative: highlighting the importance of fundamental studies and the use of NaPh4B as additive in the design and applications of mercury(II) ion selective electrodes [J].
de Namor, Angela F. Danil ;
El Gamouz, Abdelaziz ;
Alharthi, Salman ;
Al Hakawati, Nawal ;
Varcoe, John R. .
JOURNAL OF MATERIALS CHEMISTRY A, 2015, 3 (24) :13016-13030
[10]   Ho3+ carbon paste sensor based on multi-walled carbon nanotubes: Applied for determination of holmium content in biological and environmental samples [J].
Faridbod, Farnoush ;
Ganjali, Mohammad Reza ;
Larijani, Bagher ;
Hosseini, Morteza ;
Norouzi, Parviz .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (04) :555-560