We studied the holding power during cut-out tests of 4 different screw fixation devices of the femoral head, correlated to head size and bone density, on 48 paired deep frozen proximal femurs of fresh gross specimens. We found no significant effect of the device on the holding power. There was a significantly higher maximal load at failure in large and dense heads. It seems then unnecessary to advocate more sophisticated but also more expensive devices to fix femoral neck fractures.
引用
收藏
页码:435 / 438
页数:4
相关论文
共 11 条
[1]   IMPLANT HOLDING POWER OF THE FEMORAL-HEAD - A CADAVER STUDY OF FRACTURE SCREWS [J].
BENTERUD, JG ;
HUSBY, T ;
GRAADAHL, O ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :47-49
[2]   AXIAL-COMPRESSION IN FEMORAL-NECK OSTEOTOMIES - A BIOMECHANIC STUDY IN HUMAN CADAVER HIPS [J].
FRANDSEN, PA ;
MADSEN, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1983, 54 (05) :703-707
[3]   SCREW FIXATION IN THE FEMORAL-HEAD - PULL-OUT TESTS IN CADAVERS [J].
IVERSEN, BF ;
STURUP, J ;
LYNDRUP, P ;
JENSEN, NC ;
THERKILDEN, MH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (06) :655-657
[4]  
KEMPF I, 1993, REV CHIR ORTHOP, V79, P29
[5]   HOLDING POWER IMPAIRED IN RHEUMATOID FEMORAL HEADS - CADAVERIC STUDY OF FRACTURE FIXATION DEVICES [J].
LARSSON, S ;
ELLOY, M .
ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (06) :502-506
[6]   Choice of implant for internal fixation of femoral neck fractures - Meta-analysis of 25 randomised trials including 4,925 patients [J].
Parker, MJ ;
Blundell, C .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (02) :138-143
[7]  
REGAZZONI P, 1986, DYNAMIC HIP SCREW
[8]   FIXATION OF FEMORAL-NECK FRACTURES - COMPARISON OF THE UPPSALA AND VON-BAHR SCREWS [J].
REHNBERG, L ;
OLERUD, C .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (05) :579-584
[9]   THE AO DYNAMIC HIP SCREW AND THE PUGH SLIDING NAIL IN FEMORAL-HEAD FIXATION [J].
RICHARDS, RH ;
EVANS, G ;
EGAN, J ;
SHEARER, JR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (05) :794-796
[10]   BONE-MINERAL CONTENT AND FIXATION STRENGTH OF FEMORAL-NECK FRACTURES - A CADAVER STUDY [J].
SJOSTEDT, A ;
ZETTERBERG, C ;
HANSSON, T ;
HULT, E ;
EKSTROM, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :161-165