Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla

被引:27
作者
Edelman, Robert R. [1 ,2 ]
Giri, S. [3 ]
Pursnani, A. [1 ,4 ]
Botelho, M. P. F. [1 ]
Li, W. [1 ,4 ]
Koktzoglou, I. [1 ,4 ]
机构
[1] NorthShore Univ HealthSyst, Dept Radiol, Evanston, IL 60201 USA
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Siemens Med Solut USA Inc, Chicago, IL USA
[4] Univ Chicago, Pritzker Sch Med, Chicago, IL 60637 USA
关键词
Quiescent-interval slice-selective (QISS); Coronary artery; Magnetic resonance angiography; Breath-holding; Navigator; Free-breathing; MR-ANGIOGRAPHY; K-SPACE; HEART; DISEASE; INVERSION; SYSTEM;
D O I
10.1186/s12968-015-0205-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enhanced, quiescent-interval slice-selective (QISS) 2D technique. Sequence performance was compared at 1.5 and 3 Tesla using both radial and Cartesian k-space trajectories. Methods: The left coronary circulation was imaged in six healthy subjects and two patients with coronary artery disease. Breath-hold QISS was compared with T2-prepared 2D balanced steady-state free-precession (bSSFP) and free-breathing, navigator-gated 3D bSSFP. Results: Approximately 10 2.1-mm thick slices were acquired in a single similar to 20-s breath-hold using two-shot QISS. QISS contrast-to-noise ratio (CNR) was 1.5-fold higher at 3 Tesla than at 1.5 Tesla. Cartesian QISS provided the best coronary-to-myocardium CNR, whereas radial QISS provided the sharpest coronary images. QISS image quality exceeded that of free-breathing 3D coronary MRA with few artifacts at either field strength. Compared with T2-prepared 2D bSSFP, multi-slice capability was not restricted by the specific absorption rate at 3 Tesla and pericardial fluid signal was better suppressed. In addition to depicting the coronary arteries, QISS could image intra-cardiac structures, pericardium, and the aortic root in arbitrary slice orientations. Conclusions: Breath-hold QISS is a simple, versatile, and time-efficient method for coronary MRA that provides excellent image quality at both 1.5 and 3 Tesla. Image quality exceeded that of free-breathing, navigator-gated 3D MRA in a much shorter scan time. QISS also allowed rapid multi-slice bright-blood, diastolic phase imaging of the heart, which may have complementary value to multi-phase cine imaging. We conclude that, with further clinical validation, QISS might provide an efficient alternative to commonly used free-breathing coronary MRA techniques.
引用
收藏
页数:10
相关论文
共 26 条
[1]  
[Anonymous], 2010, MAGN RESON MED
[2]   MRI of the coronary vessel wall at 3 T: Comparison of radial and cartesian k-space sampling [J].
Bansmann, Paul M. ;
Priest, Andrew N. ;
Muellerleile, Kai ;
Stork, Alexander ;
Lund, Gunnar K. ;
Kaul, Michael G. ;
Adam, Gerhard .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :70-74
[3]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[4]   Ungated Radial Quiescent-Inflow Single-Shot (UnQISS) Magnetic Resonance Angiography Using Optimized Azimuthal Equidistant Projections [J].
Edelman, Robert R. ;
Giri, Shivraman ;
Murphy, Ian G. ;
Flanagan, Oisin ;
Speier, Peter ;
Koktzoglou, Ioannis .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) :1522-1529
[5]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[6]   Pericardial sinuses and recesses: Findings at electrocardiographically triggered electron-beam CT [J].
Groell, R ;
Schaffler, GJ ;
Rienmueller, R .
RADIOLOGY, 1999, 212 (01) :69-73
[7]   Evaluation of Peripheral Arterial Disease with Nonenhanced Quiescent-Interval Single-Shot MR Angiography [J].
Hodnett, Philip A. ;
Koktzoglou, Ioannis ;
Davarpanah, Amir H. ;
Scanlon, Timothy G. ;
Collins, Jeremy D. ;
Sheehan, John J. ;
Dunkle, Eugene E. ;
Gupta, Navyash ;
Carr, James C. ;
Edelman, Robert R. .
RADIOLOGY, 2011, 260 (01) :282-293
[8]   Assessment of Coronary Artery Disease Using Magnetic Resonance Coronary Angiography A National Multicenter Trial [J].
Kato, Shingo ;
Kitagawa, Kakuya ;
Ishida, Nanaka ;
Ishida, Masaki ;
Nagata, Motonori ;
Ichikawa, Yasutaka ;
Katahira, Kazuhiro ;
Matsumoto, Yuji ;
Seo, Koji ;
Ochiai, Reiji ;
Kobayashi, Yasuyuki ;
Sakuma, Hajime .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (12) :983-991
[9]   Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion:: Initial results [J].
Katoh, M ;
Buecker, A ;
Stuber, M ;
Günther, RW ;
Spuentrup, E .
KIDNEY INTERNATIONAL, 2004, 66 (03) :1272-1278
[10]   Polar sampling in k-space: Reconstruction effects [J].
Lauzon, ML ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (05) :769-782