A continuous low-temperature magnetic refrigerator

被引:0
|
作者
Shirron, PJ [1 ]
Canavan, ER [1 ]
DiPirro, MJ [1 ]
Jackson, M [1 ]
Panek, J [1 ]
Tuttle, JG [1 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
来源
LOW TEMPERATURE DETECTORS | 2002年 / 605卷
关键词
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report on recent progress in the development of a continuous adiabatic demagnetization refrigerator (ADR). Continuous operation avoids the constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, allowing us to achieve an order of magnitude larger cooling power per unit mass. Our current design goal is 10 muW of cooling at 50 mK using a 6-10 K heat sink. The estimated mass is less than 10 kg, including magnetic shielding of each stage, The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long mission life and reduced complexity and cost. We have assembled a three-stage ADR and have demonstrated continuous cooling using a superfluid helium bath as the heat sink. The temperature stability is 8 muK rms or better over the entire cycle, and the cooling power is 2.5 muW at 60 mK rising to 10 muW at 100 mK.
引用
收藏
页码:379 / 382
页数:4
相关论文
共 50 条
  • [1] Low-temperature Revision of the Mini-refrigerator
    金哲
    延边大学学报(自然科学版), 2002, (03) : 223 - 225
  • [2] LOW-TEMPERATURE BLACKBODY BASED ON THERMOELECTRIC REFRIGERATOR
    KOGAN, AV
    KOLENKO, EA
    NECHAI, ES
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (06): : 1439 - &
  • [3] Assessment of the operation of a low-temperature adsorption refrigerator
    Chalaev D.M.
    Aristov Yu.I.
    Thermal Engineering, 2006, 53 (3) : 240 - 244
  • [4] Low-temperature thawing Refrigerator Based on the Internet of Things
    Wang, Shuqing
    Lei, Guibin
    Wan, Wei
    Zhang, Ying
    Li, Canping
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 5961 - 5965
  • [5] A LOW-TEMPERATURE NMR PROBE FOR USE IN A DILUTION REFRIGERATOR
    KUHNS, PL
    LEE, SH
    CORETSOPOULOS, C
    HAMMEL, PC
    GONEN, O
    WAUGH, JS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (09): : 2159 - 2162
  • [6] Development of a dilution refrigerator for low-temperature microgravity experiments
    Roach, PR
    Helvensteijn, BPM
    CRYOCOOLERS 10, 1999, : 647 - 653
  • [7] A LOW-TEMPERATURE CONTINUOUS EXTRACTOR
    MOSKOWITZ, M
    SCIENCE, 1947, 105 (2737) : 624 - 625
  • [8] ON THE THERMODYNAMIC CYCLE OF THE LOW-TEMPERATURE G-M REFRIGERATOR
    HONG, CS
    XU, XD
    CRYOGENICS, 1994, 34 : 183 - 186
  • [9] Stepwise and continuous low-temperature demagnetization
    Dunlop, DJ
    GEOPHYSICAL RESEARCH LETTERS, 2003, 30 (11)
  • [10] CONTINUOUS LOW-TEMPERATURE RENDERING PROCESS
    SULLIVAN, FE