Modelling and calibration of a conventional activated sludge wastewater treatment plant

被引:0
|
作者
Birs, Isabela R. [1 ]
Nascu, Ioana [2 ]
Darab, Cosmin [1 ]
Nascu, Ioan [1 ]
机构
[1] Tech Univ Cluj Napoca, Dept Automat, Cluj Napoca, Romania
[2] Imperial Coll London, CPSE, Dept Chem Engn, London, England
来源
PROCEEDING OF 2016 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR) | 2016年
关键词
wastewater treatment; reduced order model; on-line control; modelling; validation;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Wastewater treatment plants (WWTPs) are key infrastructures for ensuring a proper protection of the environment. Mathematical modelling and simulation of activated sludge systems have gained increasing attention in control engineering within the last years. The most widely used models to describe the biochemical processes that take place in a WWTP are the Activated Sludge Models 1-3. Due to their increased complexity, these models are often unsuited for control systems design. The aim of this paper is to develop reduced order models which can adequately describe the biochemical processes for the purpose of on-line control design. The models developed contain a minimum number of variables and parameters that allow for model identification and validation based on available on-line measurements.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [21] Evolution of polycyclic aromatic hydrocarbons (PAHs) and heavy metals in sludge samples from conventional activated sludge wastewater treatment plants
    Villar, P.
    Villar, M.
    Callejon, M.
    Perez, J. L.
    Jimenez, J. C.
    Alonso, E.
    Guiraum, A.
    ENVIRONMETRICS, 2009, 20 (05) : 561 - 574
  • [22] Assessment of microbial aerosol emissions in an urban wastewater treatment plant operated with activated sludge process
    Fathi, Saied
    Hajizadeh, Yaghoub
    Nikaeen, Mahnaz
    Gorbani, Mozhgan
    AEROBIOLOGIA, 2017, 33 (04) : 507 - 515
  • [23] Assessment of microbial aerosol emissions in an urban wastewater treatment plant operated with activated sludge process
    Saied Fathi
    Yaghoub Hajizadeh
    Mahnaz Nikaeen
    Mozhgan Gorbani
    Aerobiologia, 2017, 33 : 507 - 515
  • [24] Dynamical modelling of an activated sludge system of a petrochemical plant operating at high temperatures
    Maqueda, M. A. M.
    Martinez D, Sergio A.
    Narvaez, D.
    Rodriguez R, Miriam G.
    Aguilar L, Ricardo
    Herrero V, Victor M.
    WATER SCIENCE AND TECHNOLOGY, 2006, 53 (11) : 135 - 142
  • [25] The fate of lindane in the conventional activated sludge treatment process
    Kipopoulou, AM
    Zouboulis, A
    Samara, C
    Kouimtzis, T
    CHEMOSPHERE, 2004, 55 (01) : 81 - 91
  • [26] AN INVARIANT OBSERVER FOR ACTIVATED SLUDGE WASTEWATER TREATMENT PROCESS
    Liu, Ying-Bo
    Zong, Xi-Ju
    Sun, Yan-Xia
    Cheng, Xin-Gong
    2016 13TH INTERNATIONAL COMPUTER CONFERENCE ON WAVELET ACTIVE MEDIA TECHNOLOGY AND INFORMATION PROCESSING (ICCWAMTIP), 2016, : 366 - 371
  • [27] Wastewater treatment in a hybrid activated sludge baffled reactor
    Tizghadam, Mostafa
    Dagot, Christophe
    Baudu, Michel
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 154 (1-3) : 550 - 557
  • [28] Segmentation and Quantification of Activated Sludge Flocs for Wastewater Treatment
    Khan, Muhammad Burhan
    Nisar, Humaira
    Aun, Ng Choon
    2014 IEEE CONFERENCE ON OPEN SYSTEMS (ICOS), 2014, : 18 - 23
  • [29] Excess Sludge Minimization in Conventional Activated Sludge Pilot Plant by Three Chemical Matters
    Hassani, A. H.
    Nejaei, A.
    Torabian, A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2011, 5 (04) : 981 - 988
  • [30] Phthalates, nonylphenols and LAS in an alternately operated wastewater treatment plant - fate modelling based on measured concentrations in wastewater and sludge
    Fauser, P
    Vikelsoe, J
    Sorensen, PB
    Carlsen, L
    WATER RESEARCH, 2003, 37 (06) : 1288 - 1295