A parameter study of tube bundle heat exchangers for fouling rate reduction

被引:130
作者
Han, Hui [1 ]
He, Ya-Ling [1 ]
Tao, Wen-Quan [1 ]
Li, Yin-Shi [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermo Fluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
关键词
Particulate deposit; Heat exchanger; Heat transfer; Pressure drop; Numerical simulation; NUMERICAL EVALUATION; ASH DEPOSITION; PARTICLE; BOILERS; IMPACT; MODEL;
D O I
10.1016/j.ijheatmasstransfer.2014.01.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
The formation of particulate deposits on flue gas heat exchanger surfaces will reduce heat transfer efficiency, increase the instability of equipment operation and introduce a major uncertainty into the heat exchanger design. In this paper, a numerical model was developed to predict the flue-ash particle deposition rate by considering particles transport, sticking and rebound behaviors based on the software FLUENT, extended by user-defined functions (UDFs). The numerical model was applied to cross-flow tube bundle heat exchangers with a 6-row tube arrangement. The effects of six parameters (particle diameter, flow velocity, spanwise tube pitch, longitudinal tube pitch, tube geometry shape, and arrangement) on fouling rate, as well as on the heat transfer and hydrodynamics performance, were examined. It was found that particle deposits accumulated primarily in the flow stagnation region, recirculation region, the vortex separation and reattachment regions. Increasing particle diameter moved the deposition zones towards the windward side of tubes. Using both oval tubes and staggered arrangements can reduce the fouling rate. With the increase in longitudinal tube pitch, both the particulate deposit rate and the heat transfer performance increased. To account for fouling and heat transfer performance, a tube spacing value of 2 was recommended. (c) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:210 / 221
页数:12
相关论文
共 25 条
[1]   Modelling the impaction of a micron particle with a powdery layer [J].
Abd-Elhady, M. S. ;
Rindt, C. C. M. ;
Wijers, J. G. ;
van Steenhoven, A. A. .
POWDER TECHNOLOGY, 2006, 168 (03) :111-124
[2]   Influence of the Apex Angle of Cone-Shaped Tubes on Particulate Fouling of Heat Exchangers [J].
Abd-Elhady, Mohamed S. ;
Rindt, Camilo C. M. ;
Van Steenhoven, Anton A. .
HEAT TRANSFER ENGINEERING, 2011, 32 (3-4) :272-281
[3]   Minimum gas speed in heat exchangers to avoid particulate fouling [J].
Abd-Elhady, MS ;
Rindt, CCM ;
Wijers, JG ;
van Steenhoven, AA ;
Bramer, EA ;
van der Meer, TH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (17-18) :3943-3955
[4]   A MECHANISTIC DESCRIPTION OF ASH DEPOSITION DURING PULVERIZED COAL COMBUSTION - PREDICTIONS COMPARED WITH OBSERVATIONS [J].
BAXTER, LL ;
DESOLLAR, RW .
FUEL, 1993, 72 (10) :1411-1418
[5]  
Beek MV, 2001, Gas-side fouling in heat-recovery boilers
[6]   Design of a novel, intensified heat exchanger for reduced fouling rates [J].
Bouris, D ;
Konstantinidis, E ;
Balabani, S ;
Castiglia, D ;
Bergeles, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (18) :3817-3832
[7]   Numerical evaluation of alternate tube configurations for particle deposition rate reduction in heat exchanger tube bundles [J].
Bouris, D ;
Papadakis, G ;
Bergeles, G .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2001, 22 (05) :525-536
[8]  
Bouris D., 1997, INT J HEAT MASS TRAN, V40, P4037
[9]  
Goldsmith W., 1960, IMPACT
[10]   SURFACE ENERGY AND CONTACT OF ELASTIC SOLIDS [J].
JOHNSON, KL ;
KENDALL, K ;
ROBERTS, AD .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1971, 324 (1558) :301-&