The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

被引:29
作者
Gao Si-jia [1 ]
Zhang Meng-wei [1 ]
Liu Xi-ping [1 ]
Zhu Yu-shen [1 ]
Liu Jing-hong [1 ]
Wang Zhong-hui [1 ]
Zang Pei-zhuo [2 ]
Shi Qiang [1 ]
Wang Qiang [1 ]
Liang Chuan-sheng [2 ]
Xu Ke [1 ]
机构
[1] China Med Univ, Affiliated Hosp 1, Dept Radiol, Shenyang 110001, Peoples R China
[2] China Med Univ, Affiliated Hosp 1, Dept Neurosurg, Shenyang 110001, Peoples R China
关键词
Vascular malformation; Arteriovenous fistulas; Spinal cord; Angiography; Computed tomography; Central nervous system; ENHANCED MR-ANGIOGRAPHY; DURAL ARTERIOVENOUS-FISTULA; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; FEEDING ARTERIES; ADAMKIEWICZ; 1ST-PASS;
D O I
10.1016/j.ejrad.2008.04.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with "sure start" technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with chi(2)-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The type differentiations of all the other 16 patients were consistent with DSA results. For 13 cases with positive CT spinal angiography results, DSA displayed 20 feeding vessels, among which 16 vessels were displayed correctly by CT spinal angiography, four could not be visualized, and two turned out to be false-positive. Fistulas were not displayed in six cases by CT spinal angiography. Draining veins were displayed clearly in all cases, which agreed with DSA results. Four cases who took CE-MRA obtained the same type diagnosis as that from CT spinal angiography. Feeding arteries were not displayed in CE-MRA of one case, but could be clearly visualized in other three cases, and the results agreed with CTA and DSA results. Fistulas could be seen in two cases. Draining veins and the disease range could be displayed distinctly by 3D CE-MRA. Conclusion: CT spinal angiography is quite valuable for diagnosing vascular malformation of spinal cord. It can be a screening exam before DSA, and has a guiding effect on DSA, reducing the amount of time required for DSA. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 18 条
  • [1] Diagnosis of spinal dural arteriovenous fistula with multidetector row computed tomography: a case report
    Bertrand, D
    Douvrin, F
    Gerardin, E
    Clavier, E
    Proust, F
    Thiebot, J
    [J]. NEURORADIOLOGY, 2004, 46 (10) : 851 - 854
  • [2] Binkert CA, 1999, AM J NEURORADIOL, V20, P1785
  • [3] Bowen BC, 1996, AM J NEURORADIOL, V17, P483
  • [4] Spinal dural arteriovenous fistula localization with a technique of first-pass gadolinium-enhanced MR angiography: Initial experience
    Farb, RI
    Kim, JK
    Willinsky, RA
    Montanera, WJ
    terBrugge, K
    Derbyshire, JA
    van Dijk, JMC
    Wright, GA
    [J]. RADIOLOGY, 2002, 222 (03) : 843 - 850
  • [5] Usefulness of preoperative detection of artery of Adamkiewitcz with dynamic contrast-enhanced MR angiography
    Hyodoh, H
    Kawaharada, N
    Akiba, H
    Tamakawa, M
    Hyodoh, K
    Fukada, J
    Morishita, K
    Hareyama, M
    [J]. RADIOLOGY, 2005, 236 (03) : 1004 - 1009
  • [6] KOHSUKE K, 2003, AJNR, V24, P13
  • [7] Lai PH, 2006, AM J NEURORADIOL, V27, P813
  • [8] Multi-detector row computed tomography angiography in diagnosing spinal dural arteriovenous fistula - Initial experience
    Lai, PH
    Pan, HB
    Yang, CF
    Yeh, LR
    Hsu, SS
    Lee, KW
    Weng, MJ
    Wu, MT
    Liang, HL
    Chen, CK
    [J]. STROKE, 2005, 36 (07) : 1562 - 1564
  • [9] MASCALCHI M, 1995, AM J NEURORADIOL, V16, P289
  • [10] Mascalchi M, 1997, AM J NEURORADIOL, V18, P351