Maximum permissible torsional misalignment in aberration-sensing and wavefront-guided corneal ablation

被引:47
作者
Bueeler, M
Mrochen, M
Seiler, T
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, Swiss Fed Inst Technol Zurich, CH-8092 Zurich, Switzerland
[2] Inst Refract & Oculoplast Surg, Zurich, Switzerland
关键词
D O I
10.1016/S0886-3350(03)00645-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the maximum permissible torsional misalignment in wavefront-guided refractive surgery. Setting. University of Zurich, Department of Ophthalmology, Zurich, Switzerland. Methods: The effect of torsionally misaligned ablations on the optical outcome was simulated using measured wavefront aberration patterns (2nd to 6th orders) in 130 normally aberrated eyes. The calculations were done for 3.0 mm, 5.0 mm, and 7.0 mm pupils. The optical quality of the simulated correction was rated by the root-mean-square residual wavefront error. Results: The required accuracy of torsional alignment is higher for the correction of higher-order aberrations than for cylindrical treatments only. To improve the optical performance to the level of the best 10% of a normal, untreated population, ablation would have to occur within a tolerance range of 4.0 degrees for 7.0 mm pupils. Conclusions: The tolerance range for torisional alignment in wavefront-guided higher-order corrections depends on the amount of original optical error in each eye. Rough centration based on the surgeon's judgment may not be accurate enough to achieve significantly improved optical quality in a high percentage of treated eyes.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 31 条
  • [11] HOLLADAY JT, 1992, REFRACTIVE KERATOTOM, P37
  • [12] Kaemmerer M, 2000, INVEST OPHTH VIS SCI, V41, pS679
  • [13] Mesopic vision after LASIK for myopia
    Knorz, MC
    Hugger, P
    Jendritzka, B
    Liermann, A
    [J]. OPHTHALMOLOGE, 1999, 96 (11): : 711 - 716
  • [14] Maguire L J, 1991, Refract Corneal Surg, V7, P122
  • [15] MAHAJAN VN, 1998, OPTICAL IMAGING AB 1, P437
  • [16] Automated ocular wavefront analyzer for clinical use
    Mierdel, P
    Kaemmerer, M
    Mrochen, M
    Krinke, HE
    Seiler, T
    [J]. OPHTHALMIC TECHNOLOGIES X, 2000, 3908 : 86 - 92
  • [17] Mierdel P, 1997, OPHTHALMOLOGE, V94, P441, DOI 10.1007/s003470050140
  • [18] Mrochen M, 2000, J REFRACT SURG, V16, P116
  • [19] Is the human eye a perfect optic?
    Mrochen, M
    Kaemmerer, M
    Mierdel, P
    Krinke, HE
    Seiler, T
    [J]. OPHTHALMIC TECHNOLOGIES XI, 2001, 4245 : 30 - 35
  • [20] Increased higher-order optical aberrations after laser refractive surgery - A problem of subclinical decentration
    Mrochen, M
    Kaemmerer, M
    Mierdel, P
    Seiler, T
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (03) : 362 - 369