Purpose: To determine the maximum permissible torsional misalignment in wavefront-guided refractive surgery. Setting. University of Zurich, Department of Ophthalmology, Zurich, Switzerland. Methods: The effect of torsionally misaligned ablations on the optical outcome was simulated using measured wavefront aberration patterns (2nd to 6th orders) in 130 normally aberrated eyes. The calculations were done for 3.0 mm, 5.0 mm, and 7.0 mm pupils. The optical quality of the simulated correction was rated by the root-mean-square residual wavefront error. Results: The required accuracy of torsional alignment is higher for the correction of higher-order aberrations than for cylindrical treatments only. To improve the optical performance to the level of the best 10% of a normal, untreated population, ablation would have to occur within a tolerance range of 4.0 degrees for 7.0 mm pupils. Conclusions: The tolerance range for torisional alignment in wavefront-guided higher-order corrections depends on the amount of original optical error in each eye. Rough centration based on the surgeon's judgment may not be accurate enough to achieve significantly improved optical quality in a high percentage of treated eyes.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 31 条
  • [1] Applegate RA, 2000, J REFRACT SURG, V16, P507
  • [2] Corneal aberrations and visual performance after radial keratotomy
    Applegate, RA
    Howland, HC
    Sharp, RP
    Cottingham, AJ
    Yee, RW
    [J]. JOURNAL OF REFRACTIVE SURGERY, 1998, 14 (04): : 397 - 407
  • [3] Corneal topographic evaluation of decentration in photorefractive keratectomy: Treatment displacement vs intraoperative drift
    Azar, DT
    Yeh, PC
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (03) : 312 - 320
  • [4] BAILEY IL, 1998, BORISHS CLIN REFRACT, P178
  • [5] BALLENTINE C, 2002, ANN M, V1
  • [6] Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablation
    Bueeler, M
    Mrochen, M
    Seiler, T
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (02) : 257 - 263
  • [7] TOPOGRAPHICAL ANALYSIS OF THE CENTRATION OF EXCIMER LASER PHOTOREFRACTIVE KERATECTOMY
    CAVANAUGH, TB
    DURRIE, DS
    RIEDEL, SM
    HUNKELER, JD
    LESHER, MP
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 : 136 - 143
  • [8] Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations
    Guirao, A
    Williams, DR
    Cox, IG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05): : 1003 - 1015
  • [9] Corneal optical irregularity after excimer laser photorefractive keratectomy
    Hersh, PS
    Shah, SI
    Geiger, D
    Holladay, JT
    Cavanaugh, T
    Hunkeler, J
    Michelson, M
    Owen, J
    Gordon, M
    Puliafito, C
    Raizman, M
    Pepose, J
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02) : 197 - 204
  • [10] Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism
    Holladay, JT
    Moran, JR
    Kezirian, GM
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) : 61 - 79