ENERGY SAVING DESIGN OF THE AIR-CONDITIONING SYSTEM IN A HOSPITAL OPERATING DEPARTMENT

被引:0
|
作者
Tang, Wenwu [1 ]
Qin, Jinzhu [1 ]
Zhang, Yizhi [1 ]
Wang, Fengfeng [1 ]
Deng, Jie [1 ]
机构
[1] Cent S Univ, Sch Energy Sci & Engn, Changsha, Hunan, Peoples R China
来源
FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS | 2009年
关键词
Operating department; Constant volume; Secondary return air; Clean air-conditioning system; Energy saving; ROOMS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nowadays, the hospital air conditioning expenditure depends on the costs of the operating department's air-conditioning system which provides the demanding indoor condition for operations. To reduce the operation costs, a new air-conditioning system is introduced, the comparison of energy consumption and control methods between the primary return air system (PRAS) and constant volume secondary return air system (CVSRAS) is made in this paper. In contrast with PRAS, the cost can be reduced greatly with the CVSRAS. Energy cost drops by 154.21%, 49.3%, 24.77%, and 12.15% respectively under the cleanliness class I, the class 11, the class III and the class W. In addition, the control system is not more complex than PRAS. In the CVSRAS, the temperature which needs to be dealt with by air cooler is too low. So, it is necessary to choose an appropriate air cooler in the process of design. However, in the CVSRAS, the temperature in the air duct and the fan sometimes doesn't rise to the temperature required. As a result, the air supply condition does not meet the condition required. But, concerning the temperature precision is not strictly demanded, the use of the CVSRAS in the operating department is recommended.
引用
收藏
页码:2179 / 2186
页数:8
相关论文
共 50 条
  • [11] An Energy-Saving Air-Conditioning System Based on Liquid Desiccant
    Wen, Cai
    Zhang, XiaoSong
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 230 - 236
  • [12] An Energy Saving Model Predictive Control for Central Air-Conditioning System
    Wu, Zhangxian
    Yang, Guotian
    Liu, Xiangjie
    Sheng, Xing
    Song, Pengchuan
    TENCON 2009 - 2009 IEEE REGION 10 CONFERENCE, VOLS 1-4, 2009, : 356 - +
  • [13] Design of a renewable energy based air-conditioning system
    Prasartkaew, Boonrit
    Kumar, S.
    ENERGY AND BUILDINGS, 2014, 68 : 156 - 164
  • [14] Selection of an air-conditioning system for a hospital
    Said, Salem A.
    Hassan, M.A.
    Alnajjar, Rogeh K.
    Energy Engineering: Journal of the Association of Energy Engineering, 1993, 90 (03): : 24 - 34
  • [15] Study on energy-saving design and operation of hospital purification air conditioning system
    Chen, Yunyu
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2018, 13 (02) : 184 - 190
  • [16] AIR-CONDITIONING AND PARTICLE FILTRATION SYSTEMS FOR ENERGY SAVING
    TAKENAMI, T
    OHMI, T
    FUKUDA, S
    SOLID STATE TECHNOLOGY, 1989, 32 (04) : 161 - 168
  • [17] Energy-saving and optimisation of investments in air-conditioning
    Barta, J
    TELESCON 97, BUDAPEST - THE SECOND INTERNATIONAL TELECOMMUNICATIONS ENERGY SPECIAL CONFERENCE, 1997, : 373 - 377
  • [18] Energy-saving Technology of Refrigeration and Air-conditioning
    王玉鹏
    罗展雄
    谭琴
    装备制造技术, 2008, (10) : 24 - 26
  • [19] Energy Saving Conception of Smart Grid Focusing on Air-Conditioning Energy Management System
    Heydari, H.
    Bathaee, S. M. T.
    Fereidunian, A.
    Heydari, E.
    Nazarzadeh, A.
    2013 SMART GRID CONFERENCE (SGC'13), 2013, : 138 - 142
  • [20] Zigbee-based Energy Saving Control System for Centralized Air-Conditioning System
    Daud, Muhammad Nizammudin Mohd
    Abu-Samah, Asma
    2020 IEEE 10TH INTERNATIONAL CONFERENCE ON SYSTEM ENGINEERING AND TECHNOLOGY (ICSET), 2020, : 89 - 93