共 27 条
Corrosion experiments on IN-RAFM steel in flowing lead-lithium for Indian LLCB TBM
被引:5
作者:
Atchutuni, Sarada Sree
[1
]
Saraswat, Abhishek
[1
]
Sasmal, Chandra Sekhar
[1
]
Verma, S.
[1
]
Prajapati, Ashok K.
[1
]
Jaiswal, Ankur
[1
]
Gupta, Sandeep
[1
]
Chauhan, Jignesh
[1
]
Pandya, Karishma B.
[1
]
Makwana, Mayank
[1
]
Tailor, Hardik
[1
]
Agravat, Hemang S.
[1
]
Rao, Prasad P.
[1
]
Kumar, Rajendra E.
[1
]
机构:
[1] Inst Plasma Res, Bhat 382428, Gandhinagar, India
关键词:
Corrosion;
Pump driven loop;
Pb-Li;
IN-RAFM steel;
LLCB TBM;
Micro vicker's hardness;
EUROFER STEEL;
MECHANICAL-PROPERTIES;
INTERMETALLIC PHASES;
MARTENSITIC STEELS;
EUTECTIC PB-17LI;
FERROUS-ALLOYS;
DEGREES-C;
BEHAVIOR;
MICROSTRUCTURE;
COMPATIBILITY;
D O I:
10.1016/j.fusengdes.2018.05.020
中图分类号:
TL [原子能技术];
O571 [原子核物理学];
学科分类号:
0827 ;
082701 ;
摘要:
Corrosion experiments were carried out in a pump driven loop, exposing IN-RAFM (India specific Reduced Activation Ferritic Martensitic) steel samples to lead-lithium, Pb-16Li. In this loop, flat and tensile samples, made of IN-RAFM steel were exposed to lead-lithium, flowing at similar to 10 cm/s velocity and maintained at (465 +/- 3)degrees C temperature. Three experiments were carried out, for different time durations, 1000 h, 2500 h and 5000 h. Samples were removed after each experiment and metallurgical investigations were carried out using SEM and SEM/EDX. Tensile strength and hardness measurements were also carried out and the results are discussed in this paper. Corrosion rate estimated from weight loss measurements was similar to 44 mu m/year up to 2500 h and it reduced to similar to 31 mu m/year after 5000 h exposure. Iron and chromium were found leaching from the samples. Hardness reduction was observed up to similar to 40 mu m after exposing to liquid metal for 5000 h. There is no significant reduction in tensile strength and % elongation after exposing the samples up to 5000 h to liquid metal.
引用
收藏
页码:52 / 59
页数:8
相关论文