The Relationship between Diurnal Variations in Intraocular Pressure Measurements and Central Corneal Thickness and Corneal Hysteresis

被引:60
|
作者
Kotecha, Aachal [1 ,2 ,3 ,4 ]
Crabb, David P. [3 ]
Spratt, Alexander
Garway-Heath, David F. [1 ,2 ,3 ,4 ]
机构
[1] Moorfields Eye Hosp, Glaucoma Res Unit, London EC1V 2PD, England
[2] UCL Inst Ophthalmol, London, England
[3] City Univ London, Dept Optometry & Visual Sci, London, England
[4] Moorfields Eye Hosp, NIHR, NHS Fdn Trust, Biomed Res Ctr Ophthalmol, London EC1V 2PD, England
关键词
GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; BIOMECHANICAL PROPERTIES; IN-VIVO; GLAUCOMA; AGE; STROMA; EYES; VARIABILITY; EDEMA;
D O I
10.1167/iovs.08-2955
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To examine the relationship between office-hour changes in IOP, measured with the Goldmann applanation tonometer (GAT) and dynamic contour tonometer (DCT), and the corneal characteristics central corneal thickness (CCT) and corneal hysteresis (CH). METHODS. Sixty-two eyes of 62 untreated normal subjects and patients with untreated glaucoma had IOP measurements performed with the GAT (mm Hg) and DCT (mm Hg) over an 8-hour period at 2-hour intervals beginning at 9 AM. CCT (micrometers) was measured using a noncontact optical low-coherence reflectometry (OLCR) pachymeter, and CH (mm Hg) was measured with an ocular response analyzer (ORA). The associations between IOP measurements and corneal characteristics for each patient over the measurement period were assessed by using multilevel modeling. RESULTS. GAT and DCT IOP and CCT changed significantly during office hours (ANOVA; GAT: F = 19.9, P < 0.001; DCT: F = 4.6, P = 0.001; CCT: F = 16.4; P < 0.001). No significant changes were observed in CH (ANOVA; F = 1.8, P = 0.13). Multilevel modeling analysis of the interrelationships between CCT, CH, and age on IOP measurements revealed that both CCT and CH changes were significantly associated with GAT IOP changes (GAT IOP/CCT slope, 0.04 mm Hg/mu m; 95% confidence intervals [CIs], 0.02-0.06; GAT IOP/CH slope, 0.20 mm Hg/mm Hg; 95% CI, 0.01-0.39). CCT, but not CH, changes were significantly associated with DCT IOP changes (DCT IOP/CCT slope, 0.03 mm Hg/mu m; 95% CI, 0.00-0.05). However, although the association between CCT and GAT IOP was relatively uniform between subjects, association between CCT and DCT IOP showed greater intersubject variability. Age had no effect on the diurnal variation of IOP measured with either device. CONCLUSIONS. Measured IOP and corneal characteristics covary during office hours. Changes in CCT and CH are associated with changes in GAT IOP and, less consistently, with DCT IOP. The data suggest that variations in corneal characteristics explain a small proportion of the change in IOP measurements made with the GAT during office hours. (Invest Ophthalmol Vis Sci. 2009;50:4229-4236) DOI: 10.1167/iovs.08-2955
引用
收藏
页码:4229 / 4236
页数:8
相关论文
共 50 条
  • [41] Relationship between corneal hysteresis and lamina cribrosa displacement after medical reduction of intraocular pressure
    Lanzagorta-Aresti, Aitor
    Perez-Lopez, Marta
    Palacios-Pozo, Elena
    Davo-Cabrera, Juan
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (03) : 290 - 294
  • [42] Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globes
    Bao, FangJun
    Deng, ManLi
    Wang, QinMei
    Huang, JinHai
    Yang, Jing
    Whitford, Charles
    Geraghty, Brendan
    Yu, AYong
    Elsheikh, Ahmed
    EXPERIMENTAL EYE RESEARCH, 2015, 137 : 11 - 17
  • [43] Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
    Krzyzanowska-Berkowska, Patrycja
    Asejczyk-Widlicka, Magdalena
    Pierscionek, Barbara
    BMC OPHTHALMOLOGY, 2012, 12
  • [44] Diurnal variation of corneal biomechanics and intraocular pressure in normal subjects
    Oncel, Banu
    Dinc, Umut Asli
    Gorgun, Ebru
    Yalvac, Belkis Ilgaz
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (05) : 798 - 803
  • [45] Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure
    Manassakorn, Anita
    Chaidaroon, Winai
    ASIAN BIOMEDICINE, 2012, 6 (02) : 291 - 296
  • [46] Central corneal thickness measurements in premature infants
    Gunay, Murat
    Celik, Gokhan
    Gunay, Betul Onal
    Dogru, Mahmut
    Gursoy, Tugba
    Ovali, Husnu Fahri
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (03) : 496 - 500
  • [47] Evaluation of Intraocular Pressure and Central Corneal Thickness in Patients with Thyroid Ophthalmopathy
    Ersoy, Murside
    Saricaoglu, M. Sinan
    Hamurcu, Mualla S.
    Karakurt, Ahmet
    Hasiripi, Hikmet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (01): : 64 - 68
  • [48] Association between corneal hysteresis and the magnitude of intraocular pressure decrease after cataract surgery
    Deol, Madhvi
    Ehrlich, Joshua R.
    Shimmyo, Mitsugu
    Radcliffe, Nathan M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06) : 1176 - 1181
  • [49] Intraocular pressure measurement after corneal transplantation
    Bezerra, Bernardo de Padua Soares
    Chan, Elsie
    Chakrabarti, Rahul
    Vajpayee, Rasik B.
    SURVEY OF OPHTHALMOLOGY, 2019, 64 (05) : 639 - 646
  • [50] Central corneal thickness in glaucoma
    Sng, Chelvin C. A.
    Ang, Marcus
    Barton, Keith
    CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (02) : 120 - 126