The Relationship between Diurnal Variations in Intraocular Pressure Measurements and Central Corneal Thickness and Corneal Hysteresis

被引:60
|
作者
Kotecha, Aachal [1 ,2 ,3 ,4 ]
Crabb, David P. [3 ]
Spratt, Alexander
Garway-Heath, David F. [1 ,2 ,3 ,4 ]
机构
[1] Moorfields Eye Hosp, Glaucoma Res Unit, London EC1V 2PD, England
[2] UCL Inst Ophthalmol, London, England
[3] City Univ London, Dept Optometry & Visual Sci, London, England
[4] Moorfields Eye Hosp, NIHR, NHS Fdn Trust, Biomed Res Ctr Ophthalmol, London EC1V 2PD, England
关键词
GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; BIOMECHANICAL PROPERTIES; IN-VIVO; GLAUCOMA; AGE; STROMA; EYES; VARIABILITY; EDEMA;
D O I
10.1167/iovs.08-2955
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To examine the relationship between office-hour changes in IOP, measured with the Goldmann applanation tonometer (GAT) and dynamic contour tonometer (DCT), and the corneal characteristics central corneal thickness (CCT) and corneal hysteresis (CH). METHODS. Sixty-two eyes of 62 untreated normal subjects and patients with untreated glaucoma had IOP measurements performed with the GAT (mm Hg) and DCT (mm Hg) over an 8-hour period at 2-hour intervals beginning at 9 AM. CCT (micrometers) was measured using a noncontact optical low-coherence reflectometry (OLCR) pachymeter, and CH (mm Hg) was measured with an ocular response analyzer (ORA). The associations between IOP measurements and corneal characteristics for each patient over the measurement period were assessed by using multilevel modeling. RESULTS. GAT and DCT IOP and CCT changed significantly during office hours (ANOVA; GAT: F = 19.9, P < 0.001; DCT: F = 4.6, P = 0.001; CCT: F = 16.4; P < 0.001). No significant changes were observed in CH (ANOVA; F = 1.8, P = 0.13). Multilevel modeling analysis of the interrelationships between CCT, CH, and age on IOP measurements revealed that both CCT and CH changes were significantly associated with GAT IOP changes (GAT IOP/CCT slope, 0.04 mm Hg/mu m; 95% confidence intervals [CIs], 0.02-0.06; GAT IOP/CH slope, 0.20 mm Hg/mm Hg; 95% CI, 0.01-0.39). CCT, but not CH, changes were significantly associated with DCT IOP changes (DCT IOP/CCT slope, 0.03 mm Hg/mu m; 95% CI, 0.00-0.05). However, although the association between CCT and GAT IOP was relatively uniform between subjects, association between CCT and DCT IOP showed greater intersubject variability. Age had no effect on the diurnal variation of IOP measured with either device. CONCLUSIONS. Measured IOP and corneal characteristics covary during office hours. Changes in CCT and CH are associated with changes in GAT IOP and, less consistently, with DCT IOP. The data suggest that variations in corneal characteristics explain a small proportion of the change in IOP measurements made with the GAT during office hours. (Invest Ophthalmol Vis Sci. 2009;50:4229-4236) DOI: 10.1167/iovs.08-2955
引用
收藏
页码:4229 / 4236
页数:8
相关论文
共 50 条
  • [21] Central Corneal Thickness and Intraocular Pressure in Malay Children
    Heidary, Fatemah
    Gharebaghi, Reza
    Hitam, Wan Hazabbah Wan
    Naing, Nyi Nyi
    Wan-Arfah, Nadiah
    Shatriah, Ismail
    PLOS ONE, 2011, 6 (10):
  • [22] Central corneal thickness and intraocular pressure in ocular hypertension
    Consuelo Gutierrez
    Jose R. V. Casaponsa
    Francisco Munoz
    Gema Rebolleda
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 463 - 463
  • [23] Central corneal thickness and intraocular pressure in premature infants
    Sekeroglu, Mehmet Ali
    Hekimoglu, Emre
    Petricli, Ikbal Seza
    Karakaya, Jale
    Ozcan, Beyza
    Yucel, Husniye
    Kavurt, Aysen Sumru
    Bas, Ahmet Yagmur
    INTERNATIONAL OPHTHALMOLOGY, 2015, 35 (06) : 847 - 851
  • [24] Relationship between corneal sensitivity, corneal thickness, corneal diameter, and intraocular pressure in normal cats and cats with congenital glaucoma
    Telle, Mary R.
    Chen, Nickolas
    Shinsako, Daniel
    Kiland, Julie A.
    Oikawa, Kazuya
    Trane, Ralph Moller
    McLellan, Gillian J.
    VETERINARY OPHTHALMOLOGY, 2019, 22 (01) : 4 - 12
  • [25] Diurnal variation in central corneal thickness and intraocular pressure in eyes with pseudoexfoliation syndrome without glaucoma
    Keel, Stuart
    Malesic, Linda
    Chan, Siew-Pang
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (11) : 1072 - 1076
  • [26] Association between corneal hysteresis and central corneal thickness in glaucomatous and non-glaucomatous eyes
    Mangouritsas, George
    Morphis, George
    Mourtzoukos, Spyridon
    Feretis, Elias
    ACTA OPHTHALMOLOGICA, 2009, 87 (08) : 901 - 905
  • [27] Variation in corneal hysteresis and central corneal thickness among black, hispanic and white subjects
    Haseltine, Sarah J.
    Pae, Jennis
    Ehrlich, Joshua R.
    Shammas, Maya
    Radcliffe, Nathan M.
    ACTA OPHTHALMOLOGICA, 2012, 90 (08) : e626 - e631
  • [28] Corneal Hysteresis, Corneal Resistance Factor, and Intraocular Pressure Measurements in Eyes Implanted With a Small Aperture Corneal Inlay
    Agca, Alper
    Demirok, Ahmet
    Celik, Haci Ugur
    van de Pol, Corina
    Cankaya, Kadir Ilker
    Celik, Nimet Burcu
    Yasa, Dilek
    Yilmaz, Ihsan
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (12) : 831 - U86
  • [29] The Relationship of Intraocular Pressure with Age, Systolic Blood Pressure, and Central Corneal Thickness in an Asian Population
    Wong, Tina T.
    Wong, Tien Y.
    Foster, Paul J.
    Crowston, Jonathan G.
    Fong, Chee-Weng
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) : 4097 - 4102
  • [30] Influence of residual corneal bed thickness after myopic LASIK on intraocular pressure measurements
    Muller, L.