The Relationship between Diurnal Variations in Intraocular Pressure Measurements and Central Corneal Thickness and Corneal Hysteresis

被引:61
作者
Kotecha, Aachal [1 ,2 ,3 ,4 ]
Crabb, David P. [3 ]
Spratt, Alexander
Garway-Heath, David F. [1 ,2 ,3 ,4 ]
机构
[1] Moorfields Eye Hosp, Glaucoma Res Unit, London EC1V 2PD, England
[2] UCL Inst Ophthalmol, London, England
[3] City Univ London, Dept Optometry & Visual Sci, London, England
[4] Moorfields Eye Hosp, NIHR, NHS Fdn Trust, Biomed Res Ctr Ophthalmol, London EC1V 2PD, England
关键词
GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; BIOMECHANICAL PROPERTIES; IN-VIVO; GLAUCOMA; AGE; STROMA; EYES; VARIABILITY; EDEMA;
D O I
10.1167/iovs.08-2955
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To examine the relationship between office-hour changes in IOP, measured with the Goldmann applanation tonometer (GAT) and dynamic contour tonometer (DCT), and the corneal characteristics central corneal thickness (CCT) and corneal hysteresis (CH). METHODS. Sixty-two eyes of 62 untreated normal subjects and patients with untreated glaucoma had IOP measurements performed with the GAT (mm Hg) and DCT (mm Hg) over an 8-hour period at 2-hour intervals beginning at 9 AM. CCT (micrometers) was measured using a noncontact optical low-coherence reflectometry (OLCR) pachymeter, and CH (mm Hg) was measured with an ocular response analyzer (ORA). The associations between IOP measurements and corneal characteristics for each patient over the measurement period were assessed by using multilevel modeling. RESULTS. GAT and DCT IOP and CCT changed significantly during office hours (ANOVA; GAT: F = 19.9, P < 0.001; DCT: F = 4.6, P = 0.001; CCT: F = 16.4; P < 0.001). No significant changes were observed in CH (ANOVA; F = 1.8, P = 0.13). Multilevel modeling analysis of the interrelationships between CCT, CH, and age on IOP measurements revealed that both CCT and CH changes were significantly associated with GAT IOP changes (GAT IOP/CCT slope, 0.04 mm Hg/mu m; 95% confidence intervals [CIs], 0.02-0.06; GAT IOP/CH slope, 0.20 mm Hg/mm Hg; 95% CI, 0.01-0.39). CCT, but not CH, changes were significantly associated with DCT IOP changes (DCT IOP/CCT slope, 0.03 mm Hg/mu m; 95% CI, 0.00-0.05). However, although the association between CCT and GAT IOP was relatively uniform between subjects, association between CCT and DCT IOP showed greater intersubject variability. Age had no effect on the diurnal variation of IOP measured with either device. CONCLUSIONS. Measured IOP and corneal characteristics covary during office hours. Changes in CCT and CH are associated with changes in GAT IOP and, less consistently, with DCT IOP. The data suggest that variations in corneal characteristics explain a small proportion of the change in IOP measurements made with the GAT during office hours. (Invest Ophthalmol Vis Sci. 2009;50:4229-4236) DOI: 10.1167/iovs.08-2955
引用
收藏
页码:4229 / 4236
页数:8
相关论文
共 49 条
[1]   Assessment of reproducibility of measures of intraocular pressure and central corneal thickness in young white adults over a 16-h time period [J].
Aakre, BM ;
Doughty, MJ ;
Dalane, OV ;
Berg, A ;
Aamodt, O ;
Gangstad, H .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (03) :271-283
[2]   Corneal thickness values before and after oxybuprocaine 0.4% eye drops [J].
Asensio, I ;
Rahhal, SM ;
Alonso, L ;
Palanca-Sanfrancisco, JM ;
Sanchis-Gimeno, JA .
CORNEA, 2003, 22 (06) :527-532
[3]   Dynamic contour tonometry in comparison to intracameral IOP measurements [J].
Boehm, Andreas G. ;
Weber, Anja ;
Pillunat, Lutz E. ;
Koch, Rainer ;
Spoerl, Eberhard .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (06) :2472-2477
[4]   DIURNAL INTRAOCULAR-PRESSURE VARIATIONS - AN ANALYSIS OF 690 DIURNAL CURVES [J].
DAVID, R ;
ZANGWILL, L ;
BRISCOE, D ;
DAGAN, M ;
YAGEV, R ;
YASSUR, Y .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (05) :280-283
[5]  
Daxer A, 1998, INVEST OPHTH VIS SCI, V39, P644
[6]  
de VENECIA GUILLERMO, 1963, ARCH OPHTHALMOL, V69, P752
[7]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[8]   Comparison of dynamic contour tonometry with Goldman applanation tonometry over a wide range of central corneal thickness [J].
Doyle, A ;
Lachkar, Y .
JOURNAL OF GLAUCOMA, 2005, 14 (04) :288-292
[10]  
DRANCE SM, 1960, ARCH OPHTHALMOL-CHIC, V64, P494