Versatile, modular 3D microelectrode arrays for neuronal ensemble recordings: from design to fabrication, assembly, and functional validation in non-human primates

被引:45
作者
Barz, F. [1 ,2 ]
Livi, A. [3 ]
Lanzilotto, M. [3 ]
Maranesi, M. [4 ]
Bonini, L. [4 ]
Paul, O. [1 ,2 ]
Ruther, P. [1 ,2 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, IMTEK, Freiburg, Germany
[2] Univ Freiburg, BrainLinks Brain Tools, Freiburg, Germany
[3] Univ Parma, Dipartimento Neurosci, Parma, Italy
[4] Ist Italiano Tecnol, Brain Ctr Social & Motor Cognit, Parma, Italy
基金
欧洲研究理事会;
关键词
3D microelectrode array; intracortical neural probe; brain-machine interface; microelectromechanical systems; chronic neural recording in macaques; single-unit activity; reaching-grasping; ELECTRONIC DEPTH CONTROL; SILICON; MOTOR; TECHNOLOGY; SIGNALS; PROBE;
D O I
10.1088/1741-2552/aa5a90
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Application-specific designs of electrode arrays offer an improved effectiveness for providing access to targeted brain regions in neuroscientific research and brain machine interfaces. The simultaneous and stable recording of neuronal ensembles is the main goal in the design of advanced neural interfaces. Here, we describe the development and assembly of highly customizable 3D microelectrode arrays and demonstrate their recording performance in chronic applications in non-human primates. Approach. System assembly relies on a microfabricated stacking component that is combined with Michigan-style silicon-based electrode arrays interfacing highly flexible polyimide cables. Based on the novel stacking component, the lead time for implementing prototypes with altered electrode pitches is minimal. Once the fabrication and assembly accuracy of the stacked probes have been characterized, their recording performance is assessed during in vivo chronic experiments in awake rhesus macaques (Macaca mulatta) trained to execute reaching-grasping motor tasks. Main results. Using a single set of fabrication tools, we implemented three variants of the stacking component for electrode distances of 250, 300 and 350 mu m in the stacking direction. We assembled neural probes with up to 96 channels and an electrode density of 98 electrodes mm(-2). Furthermore, we demonstrate that the shank alignment is accurate to a few mu m at an angular alignment better than 1 degrees. Three 64-channel probes were chronically implanted in two monkeys providing single-unit activity on more than 60% of all channels and excellent recording stability. Histological tissue sections, obtained 52 d after implantation from one of the monkeys, showed minimal tissue damage, in accordance with the high quality and stability of the recorded neural activity. Significance. The versatility of our fabrication and assembly approach should significantly support the development of ideal interface geometries for a broad spectrum of applications. With the demonstrated performance, these probes are suitable for both semi-chronic and chronic applications.
引用
收藏
页数:16
相关论文
共 47 条
  • [31] Merriam M E, 2011, IEEE T
  • [32] A floating metal microelectrode array for chronic implantation
    Musallam, Sam
    Bak, Martin J.
    Troyk, Philip R.
    Andersen, Richard A.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2007, 160 (01) : 122 - 127
  • [33] Nicolelis M. A. L., 1998, METHODS NEURAL ENSEM, DOI [10.1201/9781420048254, DOI 10.1201/9781420048254]
  • [34] Technology Insight: future neuroprosthetic therapies for disorders of the nervous system
    Normann, Richard A.
    [J]. NATURE CLINICAL PRACTICE NEUROLOGY, 2007, 3 (08): : 444 - 452
  • [35] Ordonez JS, 2012, IEEE ENG MED BIO, P2796, DOI 10.1109/EMBC.2012.6346545
  • [36] A Compact Architecture for Three-Dimensional Neural Microelectrode Arrays
    Perlin, Gayatri E.
    Wise, Kensall D.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5806 - 5809
  • [37] Raducanu BC, 2016, PROC EUR S-STATE DEV, P385, DOI 10.1109/ESSDERC.2016.7599667
  • [38] A MEMS-based flexible multichannel ECoG-electrode array
    Rubehn, Birthe
    Bosman, Conrado
    Ostenveld, Robert
    Fries, Pascal
    Stieglitz, Thomas
    [J]. JOURNAL OF NEURAL ENGINEERING, 2009, 6 (03)
  • [39] Recent Progress in Neural Probes Using Silicon MEMS Technology
    Ruther, Patrick
    Herwik, Stanislav
    Kisban, Sebastian
    Seidl, Karsten
    Paul, Oliver
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2010, 5 (05) : 505 - 515
  • [40] CMOS-BASED HIGH-DENSITY SILICON MICROPROBE ARRAY FOR ELECTRONIC DEPTH CONTROL IN NEURAL RECORDING
    Seidl, K.
    Herwik, S.
    Nurcahyo, Y.
    Torfs, T.
    Keller, M.
    Schuettler, M.
    Neves, H.
    Stieglitz, T.
    Paul, O.
    Ruther, P.
    [J]. IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, : 232 - 235