Versatile, modular 3D microelectrode arrays for neuronal ensemble recordings: from design to fabrication, assembly, and functional validation in non-human primates

被引:45
作者
Barz, F. [1 ,2 ]
Livi, A. [3 ]
Lanzilotto, M. [3 ]
Maranesi, M. [4 ]
Bonini, L. [4 ]
Paul, O. [1 ,2 ]
Ruther, P. [1 ,2 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, IMTEK, Freiburg, Germany
[2] Univ Freiburg, BrainLinks Brain Tools, Freiburg, Germany
[3] Univ Parma, Dipartimento Neurosci, Parma, Italy
[4] Ist Italiano Tecnol, Brain Ctr Social & Motor Cognit, Parma, Italy
基金
欧洲研究理事会;
关键词
3D microelectrode array; intracortical neural probe; brain-machine interface; microelectromechanical systems; chronic neural recording in macaques; single-unit activity; reaching-grasping; ELECTRONIC DEPTH CONTROL; SILICON; MOTOR; TECHNOLOGY; SIGNALS; PROBE;
D O I
10.1088/1741-2552/aa5a90
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Application-specific designs of electrode arrays offer an improved effectiveness for providing access to targeted brain regions in neuroscientific research and brain machine interfaces. The simultaneous and stable recording of neuronal ensembles is the main goal in the design of advanced neural interfaces. Here, we describe the development and assembly of highly customizable 3D microelectrode arrays and demonstrate their recording performance in chronic applications in non-human primates. Approach. System assembly relies on a microfabricated stacking component that is combined with Michigan-style silicon-based electrode arrays interfacing highly flexible polyimide cables. Based on the novel stacking component, the lead time for implementing prototypes with altered electrode pitches is minimal. Once the fabrication and assembly accuracy of the stacked probes have been characterized, their recording performance is assessed during in vivo chronic experiments in awake rhesus macaques (Macaca mulatta) trained to execute reaching-grasping motor tasks. Main results. Using a single set of fabrication tools, we implemented three variants of the stacking component for electrode distances of 250, 300 and 350 mu m in the stacking direction. We assembled neural probes with up to 96 channels and an electrode density of 98 electrodes mm(-2). Furthermore, we demonstrate that the shank alignment is accurate to a few mu m at an angular alignment better than 1 degrees. Three 64-channel probes were chronically implanted in two monkeys providing single-unit activity on more than 60% of all channels and excellent recording stability. Histological tissue sections, obtained 52 d after implantation from one of the monkeys, showed minimal tissue damage, in accordance with the high quality and stability of the recorded neural activity. Significance. The versatility of our fabrication and assembly approach should significantly support the development of ideal interface geometries for a broad spectrum of applications. With the demonstrated performance, these probes are suitable for both semi-chronic and chronic applications.
引用
收藏
页数:16
相关论文
共 47 条
  • [1] An interconnect for out-of-plane assembled biomedical probe arrays
    Aarts, A. A. A.
    Neves, H. P.
    Puers, R. P.
    Van Hoof, C.
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (06)
  • [2] Nanotools for Neuroscience and Brain Activity Mapping
    Alivisatos, A. Paul
    Andrews, Anne M.
    Boyden, Edward S.
    Chun, Miyoung
    Church, George M.
    Deisseroth, Karl
    Donoghue, John P.
    Fraser, Scott E.
    Lippincott-Schwartz, Jennifer
    Looger, Loren L.
    Masmanidis, Sotiris
    McEuen, Paul L.
    Nurmikko, Arto V.
    Park, Hongkun
    Peterka, Darcy S.
    Reid, Clay
    Roukes, Michael L.
    Scherer, Axel
    Schnitzer, Mark
    Sejnowski, Terrence J.
    Shepard, Kenneth L.
    Tsao, Doris
    Turrigiano, Gina
    Weiss, Paul S.
    Xu, Chris
    Yuste, Rafael
    Zhuang, Xiaowei
    [J]. ACS NANO, 2013, 7 (03) : 1850 - 1866
  • [3] [Anonymous], 2016, MULT 1128A M
  • [4] [Anonymous], 2015, NEURONEXUS MATR ARR
  • [5] Decoding 3D reach and grasp from hybrid signals in motor and premotor cortices: spikes, multiunit activity, and local field potentials
    Bansal, Arjun K.
    Truccolo, Wilson
    Vargas-Irwin, Carlos E.
    Donoghue, John P.
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 2012, 107 (05) : 1337 - 1355
  • [6] Barz F, 2014, IEEE ENG MED BIO, P3977, DOI 10.1109/EMBC.2014.6944495
  • [7] Barz Falk, 2013, 2013 Transducers & Eurosensors XXVII: 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII), P884, DOI 10.1109/Transducers.2013.6626909
  • [8] Multimodal Architectonic Subdivision of the Rostral Part (Area F5) of the Macaque Ventral Premotor Cortex
    Belmalih, Abdelouahed
    Borra, Elena
    Contini, Massimo
    Gerbella, Marzio
    Rozzi, Stefano
    Luppino, Giuseppe
    [J]. JOURNAL OF COMPARATIVE NEUROLOGY, 2009, 512 (02) : 183 - 217
  • [9] A novel method of fabricating convoluted shaped electrode arrays for neural and retinal prostheses
    Bhandari, R.
    Negi, S.
    Rieth, L.
    Normann, R. A.
    Solzbacher, F.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2008, 145 : 123 - 130
  • [10] Application of floating silicon-based linear multielectrode arrays for acute recording of single neuron activity in awake behaving monkeys
    Bonini, Luca
    Maranesi, Monica
    Livi, Alessandro
    Bruni, Stefania
    Fogassi, Leonardo
    Holzhammer, Tobias
    Paul, Oliver
    Ruther, Patrick
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 (04): : 273 - 281