Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement

被引:6
|
作者
Ahmed, Mohamed Attia Ali [1 ]
Abdelhalim, Ahmed Shawkat [1 ]
机构
[1] Menia Univ, Fac Med, Ophthalmol Dept, Al Minya, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
central corneal thickness; pachymeter; intraocular pressure; corneal thickness-corrected intraocular pressure; Goldmann applanation tonometry; anterior-segment optical coherence tomography; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; APPLANATION TONOMETRY; REPEATABILITY;
D O I
10.2147/OPTH.S288391
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate variability in measured intraocular pressure (TOP) values when correlated with central corneal thickness measurements obtained by both ultrasonic and optical tools. Patients and Methods: We included 46 eyes of 46 healthy subjects (age range 35-76 years). Exclusion criteria for the current study were patients with confirmed diagnosis of glaucoma, glaucoma suspect patients and those having corneal opacities, scars or prior cornea-based laser vision correction. Central corneal thickness (CCT) was measured using two methods: ultrasonically (CCT1) by pachymeter and optically (CCT2) using anterior-segment optical coherence tomography (AS-OCT). The IOP was measured in all subjects using Goldmann applanation tonometry (GAT). Results: No significant difference was detected comparing intraocular pressure values and CCT-corrected intraocular pressure (IOPcc1 and IOPcc2) (P=0.47 and P=0.06, respectively) among the study participants. A significant negative correlation was found between corneal thickness-corrected TOP values and the measured central corneal thickness by both optical and ultrasonic tools (P=0.004 and P=0.001, respectively). Conclusion: Intraocular pressure appears to be dependent and positively correlated with CCT changes. However, this does not appear to depend largely on methods used for measuring the CCT in the current study. Corrected intraocular pressure is negatively correlated to both ultrasonically and optically measured central corneal thickness.
引用
收藏
页码:4501 / 4506
页数:6
相关论文
共 50 条
  • [41] Changes in Central Corneal Thickness, Intraocular Pressure, and Oxidation/Antioxidation Parameters at High Altitude
    Karakucuk, Sarper
    Mujdeci, Metin
    Baskol, Gulden
    Arda, Hatice
    Gumus, Koray
    Oner, Ayse
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2012, 83 (11): : 1044 - 1048
  • [42] Correlation of intraocular pressure with central corneal thickness in premature and full-term newborns
    Karahan, Eyyup
    Zengin, Mehmet Ozgur
    Tuncer, Ibrahim
    Zengin, Neslihan
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (01) : 14 - 17
  • [43] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    Pensyl, D.
    Sullivan-Mee, M.
    Torres-Monte, M.
    Halverson, K.
    Qualls, C.
    EYE, 2012, 26 (10) : 1349 - 1356
  • [44] Association Between Central Corneal Thickness and Intraocular Pressure in Patients with Refractive Anomalies and Emmetropes
    Ismaili, Mimoza
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2023, 13 (03) : 91 - 95
  • [45] Intraocular pressure and central corneal thickness in full-term newborns
    Maestri Ferreira, Claudia Cardoso
    Tavares, Ivan Maynart
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (05) : 313 - 316
  • [46] Falsely elevated intraocular pressure due to increased central corneal thickness
    Alain M. Bron
    Catherine Creuzot-Garcher
    Sophie Goudeau-Boutillon
    Philippe d’Athis
    Graefe's Archive for Clinical and Experimental Ophthalmology, 1999, 237 : 220 - 224
  • [47] The effect of central corneal thickness on intraocular pressure values using various tonometers in the dog
    Guresh, Andrew M.
    Horvath, Stephen J.
    Gemensky-Metzler, Anne
    Miller, Eric
    Yildiz, Vedat
    Myers, John V.
    Newbold, Georgina M.
    VETERINARY OPHTHALMOLOGY, 2021, 24 : 154 - 161
  • [48] Combining corneal hysteresis with central corneal thickness and intraocular pressure for glaucoma risk assessment
    D Pensyl
    M Sullivan-Mee
    M Torres-Monte
    K Halverson
    C Qualls
    Eye, 2012, 26 : 1349 - 1356
  • [49] Effects of fasting on peripapillary capillary density, peripapillary nerve fiber layer, intraocular pressure and central corneal thickness
    Nilforushan, Naveed
    Abolfathzadeh, Navid
    Banifatemi, Mohammad
    Miraftabi, Arezoo
    Sardarinia, Mahsa
    Alemzadeh, Sayyed Amirpooya
    Nilforushan, Arian
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (06) : 1439 - 1447
  • [50] ICare Pro: Age Dependent Effect of Central Corneal Thickness on Intraocular Pressure in Glaucoma and Ocular Hypertension Patients
    Hohberger, Bettina
    Sommerfeld, Carlos
    Lucio, Marianna
    Bergua, Antonio
    CURRENT EYE RESEARCH, 2020, 45 (06) : 668 - 674