Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement

被引:6
|
作者
Ahmed, Mohamed Attia Ali [1 ]
Abdelhalim, Ahmed Shawkat [1 ]
机构
[1] Menia Univ, Fac Med, Ophthalmol Dept, Al Minya, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
central corneal thickness; pachymeter; intraocular pressure; corneal thickness-corrected intraocular pressure; Goldmann applanation tonometry; anterior-segment optical coherence tomography; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; APPLANATION TONOMETRY; REPEATABILITY;
D O I
10.2147/OPTH.S288391
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate variability in measured intraocular pressure (TOP) values when correlated with central corneal thickness measurements obtained by both ultrasonic and optical tools. Patients and Methods: We included 46 eyes of 46 healthy subjects (age range 35-76 years). Exclusion criteria for the current study were patients with confirmed diagnosis of glaucoma, glaucoma suspect patients and those having corneal opacities, scars or prior cornea-based laser vision correction. Central corneal thickness (CCT) was measured using two methods: ultrasonically (CCT1) by pachymeter and optically (CCT2) using anterior-segment optical coherence tomography (AS-OCT). The IOP was measured in all subjects using Goldmann applanation tonometry (GAT). Results: No significant difference was detected comparing intraocular pressure values and CCT-corrected intraocular pressure (IOPcc1 and IOPcc2) (P=0.47 and P=0.06, respectively) among the study participants. A significant negative correlation was found between corneal thickness-corrected TOP values and the measured central corneal thickness by both optical and ultrasonic tools (P=0.004 and P=0.001, respectively). Conclusion: Intraocular pressure appears to be dependent and positively correlated with CCT changes. However, this does not appear to depend largely on methods used for measuring the CCT in the current study. Corrected intraocular pressure is negatively correlated to both ultrasonically and optically measured central corneal thickness.
引用
收藏
页码:4501 / 4506
页数:6
相关论文
共 50 条
  • [31] Relation between central corneal thickness and intraocular pressure in Punjabi population
    Kohli P.G.
    Randhawa B.K.
    Singh K.D.
    Randhawa G.S.
    Kohli A.K.
    Journal of Medical Engineering and Technology, 2010, 34 (01) : 1 - 6
  • [32] Evaluation of Intraocular Pressure and Central Corneal Thickness in Patients with Thyroid Ophthalmopathy
    Ersoy, Murside
    Saricaoglu, M. Sinan
    Hamurcu, Mualla S.
    Karakurt, Ahmet
    Hasiripi, Hikmet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (01): : 64 - 68
  • [33] The impact of central corneal thickness on intraocular pressure among Ethiopian glaucoma patients: a cross-sectional study
    Gelaw, Yeshigeta
    BMC OPHTHALMOLOGY, 2012, 12
  • [34] Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer
    Saleh, Tarek A.
    Adams, Morag
    McDermott, Bill
    Claridge, Kate G.
    Ewings, Paul
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06) : 516 - 520
  • [35] Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogs
    Park, Young-Woo
    Jeong, Man-Bok
    Kim, Tae-Hyun
    Ahn, Jae-Sang
    Ahn, Jeong-Taek
    Park, Shin-Ae
    Kim, Se-Eun
    Seo, Kangmoon
    VETERINARY OPHTHALMOLOGY, 2011, 14 (03) : 169 - 173
  • [36] Correlation between Central Corneal Thickness and Intraocular Pressure in Various Age Groups
    Marjanovic, Ivan
    Kontic, Djordje
    Hentova-Sencanic, Paraskeva
    Markovic, Vujica
    Bozic, Marija
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2010, 138 (5-6) : 279 - 286
  • [37] The relationship among race, iris color, central corneal thickness, and intraocular pressure
    Semes, Leo
    Shaikh, Adam
    McGwin, Gerald
    Bartlett, Jimmy D.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (07) : 512 - 515
  • [38] Corneal hysteresis, central corneal thickness, and intraocular pressure in rheumatoid arthritis, and their relation to disease activity
    Nossair, Ashraf Ahmed
    Kassem, Mona Kassem
    Eltanamly, Rasha Mounir
    Alahmadawy, Yomna Amr
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2021, 28 (03) : 174 - 179
  • [39] Association of central corneal thickness and 24-hour Intraocular pressure fluctuation
    Mosaed, Sameh
    Chamberlain, Winston Douglas
    Liu, John H. K.
    Medeiros, Felipe A.
    Weinreb, Robert N.
    JOURNAL OF GLAUCOMA, 2008, 17 (02) : 85 - 88
  • [40] Corneal Biomechanics and Measurement of Intraocular Pressure Measurement in Pathological Corneas
    Luebke, Jan
    Maier, Philip Christian
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (06) : 751 - 755