Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement

被引:6
|
作者
Ahmed, Mohamed Attia Ali [1 ]
Abdelhalim, Ahmed Shawkat [1 ]
机构
[1] Menia Univ, Fac Med, Ophthalmol Dept, Al Minya, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
central corneal thickness; pachymeter; intraocular pressure; corneal thickness-corrected intraocular pressure; Goldmann applanation tonometry; anterior-segment optical coherence tomography; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; APPLANATION TONOMETRY; REPEATABILITY;
D O I
10.2147/OPTH.S288391
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate variability in measured intraocular pressure (TOP) values when correlated with central corneal thickness measurements obtained by both ultrasonic and optical tools. Patients and Methods: We included 46 eyes of 46 healthy subjects (age range 35-76 years). Exclusion criteria for the current study were patients with confirmed diagnosis of glaucoma, glaucoma suspect patients and those having corneal opacities, scars or prior cornea-based laser vision correction. Central corneal thickness (CCT) was measured using two methods: ultrasonically (CCT1) by pachymeter and optically (CCT2) using anterior-segment optical coherence tomography (AS-OCT). The IOP was measured in all subjects using Goldmann applanation tonometry (GAT). Results: No significant difference was detected comparing intraocular pressure values and CCT-corrected intraocular pressure (IOPcc1 and IOPcc2) (P=0.47 and P=0.06, respectively) among the study participants. A significant negative correlation was found between corneal thickness-corrected TOP values and the measured central corneal thickness by both optical and ultrasonic tools (P=0.004 and P=0.001, respectively). Conclusion: Intraocular pressure appears to be dependent and positively correlated with CCT changes. However, this does not appear to depend largely on methods used for measuring the CCT in the current study. Corrected intraocular pressure is negatively correlated to both ultrasonically and optically measured central corneal thickness.
引用
收藏
页码:4501 / 4506
页数:6
相关论文
共 50 条
  • [21] Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness
    Carbonaro, F.
    Andrew, T.
    Mackey, D. A.
    Spector, T. D.
    Hammond, C. J.
    EYE, 2010, 24 (07) : 1165 - 1170
  • [22] Correction of intraocular pressure for changes in central corneal thickness following photorefractive keratectomy
    Munger, R
    Hodge, WG
    Mintsioulis, G
    Agapitos, PJ
    Jackson, WB
    Damji, KF
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1998, 33 (03): : 159 - 165
  • [23] Acute Changes in Central Corneal Thickness According to Experimental Adjustment of Intraocular Pressure in Normal Canine Eyes
    Park, Young-Woo
    Jeong, Man-Bok
    Lee, Eui Ri
    Lee, Yesran
    Ahn, Jae-Sang
    Kim, Soo-Hyun
    Seo, Kangmoon
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2013, 75 (11) : 1479 - 1483
  • [24] Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globes
    Bao, FangJun
    Deng, ManLi
    Wang, QinMei
    Huang, JinHai
    Yang, Jing
    Whitford, Charles
    Geraghty, Brendan
    Yu, AYong
    Elsheikh, Ahmed
    EXPERIMENTAL EYE RESEARCH, 2015, 137 : 11 - 17
  • [25] Distribution of Central Corneal Thickness and Intraocular Pressure in a Large Population of Turkish School Children
    Sakalar, Yildirim Bayezit
    Keklikci, Ugur
    Unlu, Kaan
    Alakus, Mehmet Fuat
    Yildirim, Mine
    Dag, Umut
    OPHTHALMIC EPIDEMIOLOGY, 2012, 19 (02) : 83 - 88
  • [26] Diurnal variations in intraocular pressure and central corneal thickness and the correlation between these factors in dogs
    Garzon-Ariza, Alicia
    Guisado, Alicia
    Galan, Alba
    Martin-Suarez, Eva
    VETERINARY OPHTHALMOLOGY, 2018, 21 (05) : 464 - 470
  • [27] Correlation Between Intraocular Pressure and Central Corneal Thickness in Persian Children
    Nejabat M.
    Heidary F.
    Talebnejad M.R.
    Salouti R.
    Nowroozzadeh M.H.
    Masoumpour M.
    Mahdaviazad H.
    Tajbakhsh Z.
    Keshtkar M.
    Jamali H.
    Khalili M.R.
    Movahedan H.
    Roustaei N.
    Gharebaghi R.
    Ophthalmology and Therapy, 2016, 5 (2) : 235 - 243
  • [28] Central Corneal Thickness and Intraocular Pressure in Women With Gestational Diabetes Mellitus
    Kan, Kok Wei
    Mohd, Mohd-Alif Wan
    Nik-Ahmad-Zuky, Nik Lah
    Shatriah, Ismail
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [29] Falsely elevated intraocular pressure due to increased central corneal thickness
    Bron, AM
    Creuzot-Garcher, C
    Goudeau-Boutillon, S
    d'Athis, P
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (03) : 220 - 224
  • [30] Diurnal variation of central corneal thickness and intraocular pressure in eyes with pseudoexfoliation
    Syed, Zeeshan
    Srikanth, Krishnagopal
    Nagarajan, Swathi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1607 - 1609