Immunohistochemistry comparing endoscopic vein harvesting vs. open vein harvesting on saphenous vein endothelium

被引:17
作者
Nezafati, Mohammad Hassan [1 ]
Nezafati, Pouya [2 ]
Amoueian, Sakineh [3 ]
Attaranzadeh, Armin [4 ]
Rahimi, Hamid Reza [5 ]
机构
[1] Mashhad Univ Med Sci, Emam Reza Acad Hosp, Dept Cardiac Surg, Mashhad 91878, Iran
[2] Mashhad Univ Med Sci, Student Res Comm, Mashhad 91878, Iran
[3] Mashhad Univ Med Sci, Emam Reza Acad Hosp, Dept Pathol, Mashhad 91878, Iran
[4] Mashhad Univ Med Sci, Dept Mol Pathol & Cytogenet, Mashhad 91878, Iran
[5] Mashhad Univ Med Sci, Sch Med, Dept Modern Sci & Technol, Student Res Comm, Mashhad 91878, Iran
来源
JOURNAL OF CARDIOTHORACIC SURGERY | 2014年 / 9卷
关键词
EVH; OVH; vWf; E-cadherin; Caveolin; eNOSs; BYPASS GRAFT-SURGERY; PROSPECTIVE RANDOMIZED-TRIAL; WOUND COMPLICATIONS; SAPHENECTOMY; DAMAGE; CABG;
D O I
10.1186/1749-8090-9-101
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The present study attempts to compare the immunohistochemistry (IHC) of von Willebrand factor (vWf), endothelial cadherin, Caveolin and endothelial Nitric Oxide Synthase (eNOS) in VasoView Endoscopic Vein Harvesting (EVH) versus traditional Open Vein Harvesting (OVH) techniques for Coronary Artery Bypass Graft (CABG) Surgery performed in Javad al Aemeh Hospital of Mashhad, Iran in 2013,. Methods and materials: Forty-seven patients were scheduled for CABG (30 EVH and 17 OVH) among whom patients with relatively same gender and similar age were selected. Three separate two cm vein samples were harvested from each patient's saphenous vein. Each portion was collected from distal, middle and proximal zones of the saphenous vein. The tissues were deparaffinized, and antigen retrieval was done using EZ-retriever followed by an immunohistochemistry evaluation with vWf, e-cadherin, Caveolin and eNOS. In addition, demographic questioner as of Lipid profile, FBS, BMI, and cardiovascular risk factors were collected. Data analyses, including parametric and nonparametric tests were undertaken using the SPSS 16 software. A P value < 0.05 was regarded as statistically significant. Results: The mean age of the EVH and OVH groups were 63.76 +/- 9.51 and 63.63 +/- 8.31 years respectively with no significant difference between them (p = 0.989). In addition, there was no great difference between the EVH and OVH groups in lipid profile, DM, HTN, smoking history, CVA, and valvular dysfunction (P > 0.05). Qualitative report of vWf, e-cadherin, Caveolin and eNOS reveals no significant difference between the EVH and OVH (P > 0.05). Conclusion: This study indicates that VasoView EVH technique causes no endothelial damage in comparison with OVH. This study could be a molecular confirmation for the innocuous of EVH technique.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Saphenous vein harvesting techniques for coronary artery bypass grafting: a systematic review and meta-analysis
    Nguyen Lam Vuong
    Elfaituri, Muhammed Khaled
    Eldoadoa, Mohammed
    Karimzadeh, Sedighe
    Mokhtar, Mohamed Ashraf
    Eid, Peter Samuel
    Nguyen Hai Nam
    Mostafa, Mostafa Reda
    Radwan, Ibrahim
    Zaki, Marwa Mostafa Mohamed
    Al Khudari, Rawan
    Kassem, Mahmoud
    Nguyen Tien Huy
    [J]. CORONARY ARTERY DISEASE, 2022, 33 (02) : 128 - 136
  • [22] Endoscopic versus Open Vein-Graft Harvesting in Coronary-Artery Bypass Surgery
    Lopes, Renato D.
    Hafley, Gail E.
    Allen, Keith B.
    Ferguson, T. Bruce
    Peterson, Eric D.
    Harrington, Robert A.
    Mehta, Rajendra H.
    Gibson, C. Michael
    Mack, Michael J.
    Kouchoukos, Nicholas T.
    Califf, Robert M.
    Alexander, John H.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (03) : 235 - 244
  • [23] Use of the No-Touch Saphenous Vein Harvesting Technique via Small Incisions
    Hayashi, Ichiro
    Kashima, Ichiro
    Yoshikawa, Eiji
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2020, 15 (01) : 81 - 84
  • [24] The effect of endoscopic vein harvesting in coronary artery bypass surgery:association between vein harvesting techniques and quality of conduits,wound complications,and cardiovascular events
    Jun Ran
    Yun Liu
    [J]. 中国循环杂志, 2018, (S1) : 149 - 149
  • [25] Endoscopic Vein Harvesting in Lower Extremity Arterial Bypass: A Systematic Review
    Jauhari, Y. A.
    Hughes, C. O.
    Black, S. A.
    Jones, K. G.
    Hinchliffe, R. J.
    Thompson, M. M.
    Holt, P. J.
    Karthikesalingam, A.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (06) : 621 - 639
  • [26] Vein harvesting technique for infrainguinal arterial bypass with great saphenous vein and its association with surgical site infection and graft patency
    Teixeira, Pedro G. R.
    Woo, Karen
    Weaver, Fred A.
    Rowe, Vincent L.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (05) : 1264 - U601
  • [27] Endoscopic vs open saphenous vein harvest for coronary artery bypass grafting: a prospective randomized trial
    Andreasen, Jan Jesper
    Nekrasas, Vytautas
    Dethlefsen, Claus
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (02) : 384 - 389
  • [28] Video assisted endoscopic saphenous vein harvest
    Khan, JH
    Mannion, K
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (04) : 352 - 356
  • [29] The risk factors affecting the complications of saphenous vein graft harvesting in aortocoronary bypass surgery
    Kayacioglu, Ilyas
    Camur, Gercek
    Gunay, Rafet
    Ates, Mehmet
    Sensoz, Yavuz
    Alkan, Pinar
    Idiz, Mustafa
    Yekeler, Ibrahim
    [J]. TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2007, 211 (04) : 331 - 337
  • [30] Randomized Prospective Study Comparing Conventional Subcuticular Skin Closure With Dermabond Skin Glue After Saphenous Vein Harvesting
    Krishnamoorthy, Bhuvaneswari
    Najam, Osman
    Khan, Ursalan A.
    Waterworth, Paul
    Fildes, James E.
    Yonan, Nizar
    [J]. ANNALS OF THORACIC SURGERY, 2009, 88 (05) : 1445 - 1450