Thermodynamic and thermoeconomic analysis of a 21 MW binary type air-cooled geothermal power plant and determination of the effect of ambient temperature variation on the plant performance

被引:38
作者
Kahraman, Murat [1 ]
Olcay, Ali Bahadir [2 ]
Sorguven, Esra [3 ]
机构
[1] TUBITAK Marmara Res Ctr, Energy Inst, TR-41470 Kocaeli, Turkey
[2] Yeditepe Univ, Fac Engn, Dept Mech Engn, Kayisdagi Cad, TR-34755 Istanbul, Turkey
[3] Univ Sussex, Thermofluid Mech Res Ctr, Brighton, E Sussex, England
关键词
Binary cycle; Geothermal power plant; Thermodynamic analysis; Thermoeconomic analysis; Organic Rankine cycle; Air-cooled condenser; ORGANIC RANKINE-CYCLE; EXERGY ANALYSIS; EXERGOECONOMIC ANALYSIS; HEAT-SOURCE; ENERGY; OPTIMIZATION; IMPROVEMENT; EFFICIENCY; DENIZLI; SYSTEM;
D O I
10.1016/j.enconman.2019.04.036
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermodynamic and thermoeconomic performances of a 21 MW geothermal power plant with air-cooled two level binary type organic Rankine cycle was numerically investigated based on its design and operating data. The investigated plant is the Sinem Geothermal Power Plant in Germencik, Aydin, Turkey. The paper provides a detailed comparison of the exergetic performance of this plant with other eight similar type of plant units, which make use of geothermal resources with similar specific exergies. Results indicate that the exergetic efficiency of the Sinem Geothermal Power Plant is the highest with 48.2% and the others vary between 9.6% and 42.7%. This result is mainly related to the exergy losses due to suppression of heat transfer in this plant, via low temperature brine reinjection, small temperature difference in the heat exchangers and high efficiencies of the individual components. First and second law efficiencies, as well as the exergy losses and improvement potentials of each component in the plant are also calculated. In air-cooled geothermal power plants, since ambient temperature is a critical parameter for the plant performance, both thermal and economic analysis of the plant is performed based on variation in ambient air temperature. Specifically, thermoeconomic analysis of the plant is evaluated to determine the exergoeconomic factor, the relative cost difference and the sum unit cost of the product (SUCP) of the plant. The effect of ambient temperature on the SUCP of the power plant, power generation, energy and exergy efficiencies are also examined in the present study. The results showed that; when the ambient temperature increases from 5 degrees C to 35 degrees C the reduction in power generation is 6.8 MW, energy efficiency decreases from 13.7% to 9.2% while exergy efficiency decreases from 54.9% to 36.7 and SUCP of the plant increases from nearly 230 $/GJ to 330 $/GJ.
引用
收藏
页码:308 / 320
页数:13
相关论文
共 53 条
  • [1] Exergoeconomic analysis and multi-objective optimization of a novel combined flash-binary cycle for Sabalan geothermal power plant in Iran
    Aali, A.
    Pourmahmoud, N.
    Zare, V.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 143 : 377 - 390
  • [2] Energetic and exergoeconomic assessment of a multi-generation energy system based on indirect use of geothermal energy
    Akrami, Ehsan
    Chitsaz, Ata
    Nami, Hossein
    Mahmoudi, S. M. S.
    [J]. ENERGY, 2017, 124 : 625 - 639
  • [3] [Anonymous], 2018, ANN REPORT 2017
  • [4] [Anonymous], 2018, Renewable energy statistics 2018
  • [5] Techno-economic optimization of a geothermal ORC with novel "Emeritus" heat rejection units in hot climates
    Astolfi, M.
    La Diega, L. Noto
    Romano, M. C.
    Merlo, U.
    Filippini, S.
    Macchi, E.
    [J]. RENEWABLE ENERGY, 2020, 147 : 2810 - 2821
  • [6] Binary ORC (Organic Rankine Cycles) power plants for the exploitation of medium low temperature geothermal sources - Part B: Techno-economic optimization
    Astolfi, Marco
    Romano, Matteo C.
    Bombarda, Paola
    Macchi, Ennio
    [J]. ENERGY, 2014, 66 : 435 - 446
  • [7] BEJAN A., 1996, Thermal design and optimization, P1
  • [8] Assessment and mapping of the shallow geothermal potential in the province of Cuneo (Piedmont, NW Italy)
    Casasso, Alessandro
    Sethi, Rajandrea
    [J]. RENEWABLE ENERGY, 2017, 102 : 306 - 315
  • [9] Performance evaluation of a single-flash geothermal power plant in Denizli, Turkey
    Cerci, Y
    [J]. ENERGY, 2003, 28 (01) : 27 - 35
  • [10] Performance evaluations of a geothermal power plant
    Coskun, C.
    Oktay, Z.
    Dincer, I.
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) : 4074 - 4082