Can Pulse Transit Time Be Useful for Detecting Hypertension in Patients in a Sleep Unit?

被引:12
作者
Gomez Garcia, Maria Teresa [1 ]
Troncoso Acevedo, Maria Fernanda [1 ]
Rodriguez Guzman, Marcel [1 ]
Alegre de Montaner, Raquel [2 ]
Fernandez Fernandez, Beatriz [2 ]
del Rio Camacho, Genoveva [3 ]
Gonzalez-Mangado, Nicolas [1 ]
机构
[1] IIS Fdn Jimenez Diaz, CIBERES, Resp Res Grp, Serv Neumol, Madrid, Spain
[2] IIS Fdn Jimenez Diaz, Serv Nefrol, Madrid, Spain
[3] IIS Fdn Jimenez Diaz, Serv Pediat, Madrid, Spain
来源
ARCHIVOS DE BRONCONEUMOLOGIA | 2014年 / 50卷 / 07期
关键词
Sleep apnea; Polysomnography; Pulse transit time; Sleep-disordered breathing; Arterial hypertension; RESISTANT HYPERTENSION; RISK-FACTOR; APNEA; PREVALENCE; ASSOCIATION; COMMITTEE;
D O I
10.1016/j.arbres.2013.12.001
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Pulse transit time (PTT) is the time that a pulse wave takes to travel between two different arterial points, and may be useful in estimating blood pressure. This noninvasive technique, which does not add any cost to the procedure, offers the advantage of avoiding 'arousals' during sleep measurement as occurs with ambulatory blood pressure monitoring (ABPM). We aim to confirm the usefulness of PTT for the detection of hypertension, and to study the correlation between both measurements. Methods: Prospective observational study in a multidisciplinary sleep unit. We recruited 30 consecutive patients attending a sleep clinic and ran a baseline polysomnography followed by an ABPM the following day. Average systolic and diastolic blood pressure (SBP, DBP) by PTT were calculated and compared with ABMP results. In accordance with international guidelines, patients with mean nocturnal ABMP >= 120/70 mmHg were diagnosed as having arterial hypertension. Results: Mean age of 60 years; 66% male, 80% suffered from sleep apnoea (OSAS). Taking the ABPM as the reference technique, we found that the diagnostic sensitivity of PTT is 85% with a specificity of 88% in the case of SBP, with a positive predictive value of 85% and negative predictive value of 88%. By studying the relationship between mean SBP measured by ABPM and PTT, we found a linear correlation coefficient (R) of 0.88, showing a distribution of all subjects with a difference of between +/- 15 mmHg between tests. There is also a positive correlation between mean DBP measured for the two tests, with a weaker linear correlation. Conclusions: Pulse transit time shows a strong correlation with blood pressure (measured by ABPM). PTT provides continuous, non-invasive, cuffless blood pressure monitoring free of additional cost and could be an alternative for screening hypertension. (C) 2013 SEPAR. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 25 条
[1]   Association of hypertension and sleep-disordered breathing [J].
Bixler, EO ;
Vgontzas, AN ;
Lin, HM ;
Ten Have, T ;
Leiby, BE ;
Vela-Bueno, A ;
Kales, A .
ARCHIVES OF INTERNAL MEDICINE, 2000, 160 (15) :2289-2295
[2]   Resistant hypertension: Diagnosis, evaluation, and treatment - A Scientific Statement from the American Heart Association Professional Education Committee of the Council for High Blood Pressure Research [J].
Calhoun, David A. ;
Jones, Daniel ;
Textor, Stephen ;
Goff, David C. ;
Murphy, Timothy P. ;
Toto, Robert D. ;
White, Anthony ;
Cushman, William C. ;
White, William ;
Sica, Domenic ;
Ferdinand, Keith ;
Giles, Thomas D. ;
Falkner, Bonita ;
Carey, Robert M. .
HYPERTENSION, 2008, 51 (06) :1403-1419
[3]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[4]   Incidence and Prognosis of Resistant Hypertension in Hypertensive Patients [J].
Daugherty, Stacie L. ;
Powers, J. David ;
Magid, David J. ;
Tavel, Heather M. ;
Masoudi, Frederick A. ;
Margolis, Karen L. ;
O'Connor, Patrick J. ;
Selby, Joe V. ;
Ho, P. Michael .
CIRCULATION, 2012, 125 (13) :1635-U112
[5]   THE EFFECT OF BLOOD-PRESSURE CUFF INFLATION ON SLEEP - A POLYSOMNOGRAPHIC EXAMINATION [J].
DIMSDALE, JE ;
COY, TV ;
ANCOLIISRAEL, S ;
CLAUSEN, J ;
BERRY, CC .
AMERICAN JOURNAL OF HYPERTENSION, 1993, 6 (10) :888-891
[6]   PULSE TRANSIT-TIME AS AN INDICATOR OF ARTERIAL BLOOD-PRESSURE [J].
GEDDES, LA ;
VOELZ, MH ;
BABBS, CF ;
BOURLAND, JD ;
TACKER, WA .
PSYCHOPHYSIOLOGY, 1981, 18 (01) :71-74
[7]   Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method [J].
Gesche, Heiko ;
Grosskurth, Detlef ;
Kuechler, Gert ;
Patzak, Andreas .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) :309-315
[8]   Hypertension prevalence in obstructive sleep apnoea and sex:: a population-based case-control study [J].
Hedner, J ;
Bengtsson-Boström, K ;
Peker, Y ;
Grote, L ;
Råstam, L ;
Lindblad, U .
EUROPEAN RESPIRATORY JOURNAL, 2006, 27 (03) :564-570
[9]   Cardiovascular risk factors in patients with obstructive sleep apnoea syndrome [J].
Kiely, JL ;
McNicholas, WT .
EUROPEAN RESPIRATORY JOURNAL, 2000, 16 (01) :128-133
[10]   Beat-to-Beat Tracking of Systolic Blood Pressure Using Noninvasive Pulse Transit Time During Anesthesia Induction in Hypertensive Patients [J].
Kim, Sung-Hoon ;
Song, Jun-Gol ;
Park, Ji-Hyun ;
Kim, Jung-Won ;
Park, Yong-Seok ;
Hwang, Gyu-Sam .
ANESTHESIA AND ANALGESIA, 2013, 116 (01) :94-100