Numerical Modelling and Experimental Measurements of Pesticides Dispersion in a Naturally Ventilated Greenhouse

被引:1
作者
Kittas, C. [1 ]
Katsoulas, N. [1 ]
Tsiropoulos, N. [1 ]
Bartzanas, T. [2 ]
Sapounas, A. A. [3 ]
机构
[1] Univ Thessaly, Sch Agr Sci, Dept Agr Crop Prod & Rural Env, Fytokou St, N Ionia 38446, Volos, Greece
[2] Ctr Res & Technol Thessaly, Inst Technol & Management Agr Ecosyst, Volos 38500, Greece
[3] Univ Thessaloniki, Ctr Agr Struct Control Farm Aristotle, Thermi 57001, Greece
来源
PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON HIGH TECHNOLOGY FOR GREENHOUSE SYSTEM MANAGEMENT, VOLS 1 AND 2 | 2008年 / 801期
关键词
tracer gas; numerical Simulation; turbulence model; aerial pollutants;
D O I
10.17660/ActaHortic.2008.801.113
中图分类号
S6 [园艺];
学科分类号
0902 ;
摘要
In the present study a commercial CFD code was used in order to investigate the dispersion of a pesticide inside an arch type tunnel greenhouse with continuous side vents. The greenhouse was cultivated with a tomato crop planted in double rows, which, during the period of measurements had a height of 1.5 m. In parallel, measurements were carried out in order to experimentally determine the decay rate of pesticide concentration. Air samples were continuously taken at seven points inside the greenhouse (six air pumps and one gas analyser). In the 3D numerical model calculations were done for several wind directions and wind speeds, using the experimental values as boundary conditions. The final solution for every case of wind direction and wind velocity was obtained, firstly by a converge solution under steady - state condition; and secondly by an unsteady one, where at the time which equals to zero the air volume in the experimental greenhouse was considered to contain a mixture consisting of air and the used pesticide. The simulation results that were in the same order of magnitude with the experimental values only during the first 5-6 minutes of unsteady solution and only qualitatively good agreement for the rest time, while the decay process was simulated. Even if different wind characteristics, as boundary conditions, were introduced in the CFD model every minute, the agreement remained in a qualitative level, showing that the concentration of the pesticide inside the greenhouse is a function not only of the greenhouse ventilation rate but also of the pesticide evaporation-volatilisation rate from the greenhouse crop, soil and cover surfaces. As the simulation model almost always underestimates the concentration levels inside the greenhouse, more investigation has to be carried out in order to obtain better agreement between measured and estimated values of pesticide concentration inside the greenhouse.
引用
收藏
页码:955 / +
页数:4
相关论文
共 18 条
  • [1] ABRAHEEM T, 2001, P ASAE ANN INT M SAC
  • [2] Comparison of toxicological impacts of integrated and chemical pest management in Mediterranean greenhouses
    Antón, A
    Castells, F
    Montero, JI
    Huijbregts, M
    [J]. CHEMOSPHERE, 2004, 54 (08) : 1225 - 1235
  • [3] Evaluation of respiratory and cutaneous doses of chlorothalonil during re-entry in greenhouses
    Aprea, C
    Centi, L
    Lunghini, L
    Banchi, B
    Forti, MA
    Sciarra, G
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2): : 131 - 145
  • [4] Effect of vent arrangement on windward ventilation of a tunnel greenhouse
    Bartzanas, T
    Boulard, T
    Kittas, C
    [J]. BIOSYSTEMS ENGINEERING, 2004, 88 (04) : 479 - 490
  • [5] Genotoxicity of pesticides: a review of human biomonitoring studies
    Bolognesi, C
    [J]. MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH, 2003, 543 (03) : 251 - 272
  • [6] Air flow and associated sensible heat exchanges in a naturally ventilated greenhouse
    Boulard, T
    Papadakis, G
    Kittas, C
    Mermier, M
    [J]. AGRICULTURAL AND FOREST METEOROLOGY, 1997, 88 (1-4) : 111 - 119
  • [7] Determination of greenhouse-specific aspects of ventilation using three-dimensional computational fluid dynamics
    Campen, JB
    Bot, GPA
    [J]. BIOSYSTEMS ENGINEERING, 2003, 84 (01) : 69 - 77
  • [8] FAO, 2002, The international code of conduct on the distribution and use of pesticides
  • [9] *FLUENT INC, 1998, FLUENT 5 US GUID
  • [10] Levels of metamidophos in air and vegetables after greenhouse applications by gas chromatography
    González, FJE
    Vidal, JLM
    Cano, MLC
    Galera, MM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) : 251 - 258