Investigation of the new non-invasive semi-quantitative method of 123I-IMP pediatric cerebral perfusion SPECT

被引:2
作者
Wakabayashi, Yasuharu [1 ,2 ]
Uchiyama, Mayuki [3 ]
Daisaki, Hiromitsu [2 ]
Matsumoto, Makoto [1 ]
Sakamoto, Masafumi [4 ]
Kashikura, Kenichi [2 ]
机构
[1] Saitama Prefectural Childrens Med Ctr, Div Radiol Technol, Saitama, Saitama, Japan
[2] Gunma Prefectural Coll Hlth Sci, Grad Sch Radiol Technol, Maebashi, Gumma, Japan
[3] Tokyo Jikeikai Med Univ, Div Radiol, Minato Ku, Tokyo, Japan
[4] Saitama Prefectural Resp & Cardiovasc Ctr, Div Radiol Technol, Kumagaya, Saitama, Japan
关键词
BLOOD-FLOW; SURFACE-AREA; QUANTIFICATION; CHILDREN; FORMULA; WEIGHT; HEIGHT;
D O I
10.1371/journal.pone.0241987
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In pediatric cases requiring quantification of cerebral blood flow (CBF) using I-123-N-isopropyl-p-iodoamphetamine (I-123-IMP) single-photon emission computed tomography (SPECT), arterial blood sampling is sometimes impossible due to issues such as movement, crying, or body motion. If arterial blood sampling fails, quantitative diagnostic assessment becomes impossible despite radiation exposure. We devised a new easy non-invasive microsphere (e-NIMS) method using whole-body scan data. This method can be used in conjunction with autoradiography (ARG) and can provide supportive data for invasive CBF quantification. In this study, we examined the usefulness of e-NIMS for pediatric cerebral perfusion semi-quantitative SPECT and compared it with the invasive ARG. The e-NIMS estimates cardiac output (CO) using whole-body acquisition data after I-123-IMP injection and the body surface area from calculation formula. A whole-body scan was performed 5 minutes after the I-123-IMP injection and CO was estimated by region of interest (ROI) counts measured for the whole body, lungs, and brain using the whole-body anterior image. The mean CBF (mCBF) was compared with that acquired via ARG in 115 pediatric patients with suspected cerebrovascular disorders (age 0-15 years). Although the mCBF estimated by the e-NIMS indicated a slight deviation in the extremely low- or high-mCBF cases when compared with the values acquired using the invasive ARG, there was a good correlation between the two methods (r = 0.799; p < 0.001). There were no significant differences in the mCBF values based on physical features, such as patients' height, weight, and age. Our findings suggest that I-123-IMP brain perfusion SPECT with e-NIMS is the simplest semi-quantitative method that can provide supportive data for invasive CBF quantification. This method may be useful, especially in pediatric brain perfusion SPECT, when blood sampling or identifying pulmonary arteries for CO estimation using the graph plot method is difficult.
引用
收藏
页数:12
相关论文
共 33 条
[1]   Estimation of 123I-IMP Arterial Blood Activity Using 123I-IMP Acquisition Data From the Lungs and Brain Without Any Blood Sampling Validation of Its Usefulness for Quantification of Regional Cerebral Blood Flow [J].
Abe, Shinji R. T. ;
Kato, Katsuhiko ;
Takahashi, Yoshitake ;
Fujita, Naotoshi ;
Yamashita, Masato ;
Shinoda, Masaki ;
Ikeda, Mitsuru ;
Ohta, Naotoshi ;
Kajita, Yasukazu ;
Naganawa, Shinji .
CLINICAL NUCLEAR MEDICINE, 2012, 37 (03) :258-263
[2]   Multisection cerebral blood flow MR imaging with continuous arterial spin labeling [J].
Alsop, DC ;
Detre, JA .
RADIOLOGY, 1998, 208 (02) :410-416
[3]   Age dependence of cerebral perfusion assessed by magnetic resonance continuous arterial spin labeling [J].
Biagi, Laura ;
Abbruzzese, Arturo ;
Bianchi, Maria Cristina ;
Alsop, David C. ;
Del Guerra, Alberto ;
Tosetti, Michela .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :696-702
[4]  
CHIRON C, 1992, J NUCL MED, V33, P696
[5]   Arterial spin-labeling in routine clinical practice, part 1: Technique and artifacts [J].
Deibler, A. R. ;
Pollock, J. M. ;
Kraft, R. A. ;
Tan, H. ;
Burdette, J. H. ;
Maldjian, J. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) :1228-1234
[6]   A formula to estimate the approximate surface area if height and weight be known [J].
Du Bois, D ;
Du Bois, EF .
ARCHIVES OF INTERNAL MEDICINE, 1916, 17 (06) :863-871
[7]  
FUJIMOTO S, 1968, Japanese Journal of Hygiene, V23, P437
[8]   GEOMETRIC METHOD FOR MEASURING BODY-SURFACE AREA - HEIGHT-WEIGHT FORMULA VALIDATED IN INFANTS, CHILDREN, AND ADULTS [J].
HAYCOCK, GB ;
SCHWARTZ, GJ ;
WISOTSKY, DH .
JOURNAL OF PEDIATRICS, 1978, 93 (01) :62-66
[9]  
IEEE, 1985, ACM SIGPLAN NOTICES, V22
[10]  
IIDA H, 1994, J NUCL MED, V35, P2019