摘要
AIM: To assess the efficacy of polyethylene glycol solution as an oral contrast agent in a patient population. MATERIAL AND METHODS: Patients were fasted from 12.00 am. Administration of the oral contrast medium commenced 15 min before imaging and comprised one sachet of Norgine (Klean-prep, Middlesex, UK) reconstituted in 1 1 water of which the patient took between 500-750 ml. Norgine is a balanced mixture of polyethylene glycol and electrolytes, which when added to water produces a clear colourless, iso-osmotic solution. RESULTS: In total 38 candidates were identified retrospectively covering a 2-year period. Visualization of the jejunum, ileal. Loops and ileocaecal region was excellent or sufficient in 87, 95 and 89%, respectively. The time taken to obtain complete visualization of the small bowel, from the jejunum to the ileocecal region varied from 15-240 min with an average time of 65 min and 73.7% of patients necessitating delayed imaging. CONCLUSIONS: Polyethylene glycol was demonstrated to be an excellent oral contrast medium in distending the small bowel. However, small bowel transit times were significantly delayed and problematic necessitating repeated imaging within the patient population. As result of theses findings longer examination time should be expected within a patient population and this should be borne in mind when scheduling patients. (c) 2006 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:966 / 970
页数:5
相关论文
共 11 条
[1]   MRI of the small and large bowel [J].
Debatin, JF ;
Patak, MA .
EUROPEAN RADIOLOGY, 1999, 9 (08) :1523-1534
[2]   Pathologic conditions in the small bowel: Findings at fat-suppressed gadolinium-enhanced MR imaging with an optimized suspension of oral magnetic particles [J].
Faber, SC ;
Stehling, MK ;
Holzknecht, N ;
Gauger, J ;
Helmberger, T ;
Reiser, M .
RADIOLOGY, 1997, 205 (01) :278-282
[3]   Technical innovation - Polyethylene glycol solution as an oral contrast agent for MR imaging of the small bowel [J].
Laghi, A ;
Carbone, I ;
Catalano, C ;
Iannaccone, R ;
Paolantonio, P ;
Baeli, I ;
Trenna, S ;
Passariello, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1333-1334
[4]   Optimization of oral contrast agents for MR imaging of the small bowel [J].
Lauenstein, TC ;
Schneemann, H ;
Vogt, FM ;
Herborn, CU ;
Rühm, SG ;
Debatin, JF .
RADIOLOGY, 2003, 228 (01) :279-283
[5]   Small bowel MRI using water as a contrast medium [J].
Lomas, DJ ;
Graves, MJ .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (862) :994-997
[6]   MR imaging of the small rowel using water as a contrast agent in a preliminary study with healthy volunteers [J].
Minowa, O ;
Ozaki, Y ;
Kyogoku, S ;
Shindoh, N ;
Sumi, Y ;
Katayama, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) :581-582
[7]   Non-invasive distension of the small bowel for magnetic-resonance imaging [J].
Patak, MA ;
Froehlich, JM ;
von Weymarn, C ;
Ritz, MA ;
Zollikofer, CL ;
Wentz, KU .
LANCET, 2001, 358 (9286) :987-988
[8]   MRI in the diagnosis of small bowel disease:: use of positive and negative oral contrast media in combination with enteroclysis [J].
Rieber, A ;
Aschoff, A ;
Nüssle, K ;
Wruk, D ;
Tomczak, R ;
Reinshagen, M ;
Adler, G ;
Brambs, HJ .
EUROPEAN RADIOLOGY, 2000, 10 (09) :1377-1382
[9]   Diagnostic imaging in Crohn's disease:: comparison of magnetic resonance imaging and conventional imaging methods [J].
Rieber, A ;
Wruk, D ;
Potthast, S ;
Nüssle, K ;
Reinshagen, M ;
Adler, G ;
Brambs, HJ .
INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2000, 15 (03) :176-181
[10]  
UMSCHADEN HW, 2000, EUR RADIOL, V101, P377